Lochinvar CHPA-66 2** Water Heater Specifications (3.84 UEF)
Engineered as a Electric Hybrid/Electric Heat Pump unit, Lochinvar CHPA-66 2** achieves a certified 3.84 UEF rating across its 68-gallon nominal tank, 83 gal First Hour Rating and ranks #221 of 706 in its 706-model cohort (PD 4689622), recording Pass: +1.34 / +53.6% under 2029 DOE rules. Rated annual electricity draw of 1,292 kWh/yr equates to roughly $235/yr ($2,346 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith CAHP-66 2** (3.84 UEF).
- Uniform Energy Factor
- 3.84 UEF
- Cohort UEF Rank
- #221 of 706 (top 32.4%)
- First Hour Rating
- 83 gal
- Storage Volume
- 68 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.34 / +53.6%

Within the 706-unit Hybrid/Electric Heat Pump cohort, Lochinvar CHPA-66 2** logs 3.84 UEF and ranks #221 of 706.
Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), Lochinvar CHPA-66 2** holds a +1.34 UEF (+53.6%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,292 kWh/yr for Lochinvar CHPA-66 2** runs ~$235/yr vs. ~$979/yr for a 0.92 UEF electric tank.
State electric sensitivity for Lochinvar CHPA-66 2**: 10-year operating spend spans $1,890 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,096 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Cross-shopping Lochinvar CHPA-66 2** (3.84 UEF)? Check A. O. Smith CAHP-66 2** (3.84 UEF, at parity) and American HPA10266H045DV 2** (3.84 UEF, at parity).
Where Does Lochinvar CHPA-66 2** Rank Against Peer Hybrid/Electric Heat Pump Units?
Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, Lochinvar CHPA-66 2** holds #221 of 706 (top 32.4%); inspect footprint, circuit load, and efficiency deltas here.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Lochinvar | 65 certified listings | ENERGY STAR PD 4689622 |
| Model Number | CHPA-66 2** | Draw pattern: High-Usage | CHPA-66 2** |
| Uniform Energy Factor (UEF) | 3.84 | +0.14 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 83 gal | +11 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,292 kWh/yr | +220 kWh/yr vs. 1,072 kWh/yr median | Est. $235/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 435% | +6.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 61" H x 23" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 22 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-08-13 | Certified 2026-08-13 | Markets: United States |
How Much Electricity Does CHPA-66 2** Use in Different States?
Estimated at $235/yr nationally (1,292 kWh/yr), 10-year utility spending for Lochinvar CHPA-66 2** shifts sharply between low-rate hydro and coastal grids.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $235/yr | $2,346 | $7,447 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $610/yr | $6,096 | $19,349 |
| California | 29.75 ¢/kWh ($0.2975) | $384/yr | $3,844 | $12,200 |
| Texas | 15.91 ¢/kWh ($0.1591) | $206/yr | $2,056 | $6,525 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $189/yr | $1,890 | $6,000 |
Does CPSC Flag Any Safety Notices on Lochinvar Units?
Checking 2026-11-23 SaferProducts data shows 1 notice mentioning Lochinvar; always cross-reference affected serial prefixes before ordering components. See Serial Number Lookup.
- Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
Which Competing Hybrid/Electric Heat Pump Models Compare Closest to CHPA-66 2**?
Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to Lochinvar CHPA-66 2**'s gallon capacity and 3.84 UEF efficiency.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| A. O. Smith CAHP-66 2** | Hybrid/Electric Heat Pump | 68 gal | 83 gal | 3.84 (at parity) | 1,292 |
| American HPA10266H045DV 2** | Hybrid/Electric Heat Pump | 68 gal | 83 gal | 3.84 (at parity) | 1,292 |
| RELIANCE WATER HEATERS 10-66-DHPTA 2** | Hybrid/Electric Heat Pump | 68 gal | 83 gal | 3.84 (at parity) | 1,292 |
| State CSHP-66 2** | Hybrid/Electric Heat Pump | 68 gal | 83 gal | 3.84 (at parity) | 1,292 |
| A. O. Smith HPA10-66H45DV 2** | Hybrid/Electric Heat Pump | 68 gal | 83 gal | 3.84 (at parity) | 1,292 |
What Are the Limitations of Lochinvar CHPA-66 2** and Who Should Not Install It?
Before ordering Lochinvar CHPA-66 2** (Hybrid/Electric Heat Pump, 3.84 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.
Key Limitations & Exclusions
- Lochinvar CHPA-66 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Lochinvar CHPA-66 2** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Common Homeowner Questions for Lochinvar CHPA-66 2**
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Does Lochinvar CHPA-66 2** pass the May 6, 2029 federal DOE efficiency rule?
Lochinvar CHPA-66 2** carries a verified 3.84 UEF rating (Pass: +1.34 / +53.6%), ranking #221 of 706 (top 32.4%) across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.
What doorway width and ceiling height does Lochinvar CHPA-66 2** need?
Lochinvar CHPA-66 2** stands 61 in. high with a 23 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.
What gas pipe size or electrical breaker does Lochinvar CHPA-66 2** require?
Lochinvar CHPA-66 2** uses a 240V branch circuit at 22A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.
How much electricity or energy does Lochinvar CHPA-66 2** cost per year to run?
Rated at 1,292 kWh/yr, Lochinvar CHPA-66 2** costs about $235/yr ($2,350 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $189/yr in Washington hydro tiers up to $610/yr in Hawaii).
Who should NOT install Lochinvar CHPA-66 2**, and what are its limits?
Lochinvar CHPA-66 2** (3.84 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.
How many bathrooms or people can Lochinvar CHPA-66 2** serve at peak demand?
Lochinvar CHPA-66 2** achieves a 83 gal First Hour Rating (+11 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.
Are there CPSC safety recalls or serial checks for Lochinvar CHPA-66 2**?
CPSC SaferProducts records show 1 brand-level recall notice mentioning Lochinvar as of 2026-11-23, including #05274 (2005-09-16). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
What 2026 rebates apply to Lochinvar CHPA-66 2**, and what peer compares closest?
Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is A. O. Smith CAHP-66 2** (3.84 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)