ENERGY STAR water heater model · PD 3417704

A. O. Smith HPA10-66H45DV 2** Water Heater Specifications (3.84 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, A. O. Smith HPA10-66H45DV 2** (Electric) achieves a certified 3.84 UEF rating across its 68-gallon nominal tank, 83 gal First Hour Rating (rank #221 of 706, PD 3417704) and verifies as Pass: +1.34 / +53.6% for 2029 DOE floors. Rated annual electricity draw of 1,292 kWh/yr equates to roughly $235/yr ($2,346 over 10 years) at 18.16 cents/kWh. Closest certified alternative is American HPA10266H045DV 2** (3.84 UEF).

Uniform Energy Factor
3.84 UEF
Cohort UEF Rank
#221 of 706 (top 32.4%)
First Hour Rating
83 gal
Storage Volume
68 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.34 / +53.6%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking A. O. Smith HPA10-66H45DV 2** at 3.84 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50A. O. Smith HPA10-66H45DV 2**: 3.84
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows A. O. Smith HPA10-66H45DV 2** relative to the cohort median.
Efficiency comparison & rule summary

A. O. Smith HPA10-66H45DV 2** records 3.84 UEF efficiency, putting it #221 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: A. O. Smith HPA10-66H45DV 2** exceeds 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.34 UEF (+53.6%). At EIA August 2026 national rates (18.16 cents/kWh), 1,292 kWh/yr for A. O. Smith HPA10-66H45DV 2** runs ~$235/yr vs. ~$979/yr for a 0.92 UEF electric tank.

State electric sensitivity for A. O. Smith HPA10-66H45DV 2**: 10-year operating spend spans $1,890 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,096 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside A. O. Smith HPA10-66H45DV 2** (3.84 UEF) are American HPA10266H045DV 2** (3.84 UEF, at parity) and Lochinvar CHPA-66 2** (3.84 UEF, at parity).

Where Does A. O. Smith HPA10-66H45DV 2** Rank Against Peer Hybrid/Electric Heat Pump Units?

Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, A. O. Smith HPA10-66H45DV 2** holds #221 of 706 (top 32.4%); inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandA. O. Smith144 certified listingsENERGY STAR PD 3417704
Model NumberHPA10-66H45DV 2**Draw pattern: High-UsageHPA10-66H45DV 2**
Uniform Energy Factor (UEF)3.84+0.14 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)83 gal+11 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,292 kWh/yr+220 kWh/yr vs. 1,072 kWh/yr medianEst. $235/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency435%+6.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)61" H x 23" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 22 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2025-12-12Certified 2025-12-12Markets: United States

How Much Electricity Does HPA10-66H45DV 2** Use in Different States?

Estimated at $235/yr nationally (1,292 kWh/yr), 10-year utility spending for A. O. Smith HPA10-66H45DV 2** shifts sharply between low-rate hydro and coastal grids.

Estimated Annual Electricity Cost by State Rate (1,292 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$235.00/yrHawaii$610.00/yrCalifornia$384.00/yrTexas$206.00/yrWashington$189.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $235/yr $2,346 $7,447
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $610/yr $6,096 $19,349
California 29.75 ¢/kWh ($0.2975) $384/yr $3,844 $12,200
Texas 15.91 ¢/kWh ($0.1591) $206/yr $2,056 $6,525
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $189/yr $1,890 $6,000
Estimated electricity spend (1,292 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Does CPSC Flag Any Safety Notices on A. O. Smith Units?

Checking 2026-11-23 SaferProducts data shows 4 notices mentioning A. O. Smith; always cross-reference affected serial prefixes before ordering components. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19030 (2018-11-08): A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's (CPSC Notice)
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

Which Competing Hybrid/Electric Heat Pump Models Compare Closest to HPA10-66H45DV 2**?

Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to A. O. Smith HPA10-66H45DV 2**'s gallon capacity and 3.84 UEF efficiency.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
American HPA10266H045DV 2** Hybrid/Electric Heat Pump 68 gal 83 gal 3.84 (at parity) 1,292
Lochinvar CHPA-66 2** Hybrid/Electric Heat Pump 68 gal 83 gal 3.84 (at parity) 1,292
RELIANCE WATER HEATERS 10-66-DHPTA 2** Hybrid/Electric Heat Pump 68 gal 83 gal 3.84 (at parity) 1,292
State CSHP-66 2** Hybrid/Electric Heat Pump 68 gal 83 gal 3.84 (at parity) 1,292
Lochinvar HPPA065KD 2** Hybrid/Electric Heat Pump 68 gal 83 gal 3.84 (at parity) 1,292

When Should Homeowners Skip A. O. Smith HPA10-66H45DV 2** (Hybrid/Electric Heat Pump)?

Check A. O. Smith HPA10-66H45DV 2**'s mechanical constraints—including utility space, Electric capacity, and Pass: +1.34 / +53.6% status—against typical residential installations.

Key Limitations & Exclusions

  • A. O. Smith HPA10-66H45DV 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting A. O. Smith HPA10-66H45DV 2** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing A. O. Smith HPA10-66H45DV 2** Strong Fit — 3.84 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare American HPA10266H045DV 2** footprint.

Common Homeowner Questions for A. O. Smith HPA10-66H45DV 2**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will A. O. Smith HPA10-66H45DV 2** stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.84 UEF, A. O. Smith HPA10-66H45DV 2** shows Pass: +1.34 / +53.6% relative to May 6, 2029 federal DOE limits while placing #221 of 706 (top 32.4%) among 706 Hybrid/Electric Heat Pump peers like American HPA10266H045DV 2**.

Will A. O. Smith HPA10-66H45DV 2** fit through a standard utility door and 72-inch basement ceiling?

Measuring 61 in. tall by 23 in. diameter, A. O. Smith HPA10-66H45DV 2** notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" d). Reserve space above the jacket for T&P piping and anode removal.

Do existing utility hookups support A. O. Smith HPA10-66H45DV 2** during replacement?

Electrical specs for A. O. Smith HPA10-66H45DV 2** call for 240V at 22A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

What is the estimated 10-year operating spend for A. O. Smith HPA10-66H45DV 2**?

At 18.16 cents/kWh national residential pricing, A. O. Smith HPA10-66H45DV 2**'s 1,292 kWh/yr draw equals roughly $235 annually or $2,350 across a 10-year horizon (ranging from $189/yr in Washington hydro tiers up to $610/yr in Hawaii).

When is A. O. Smith HPA10-66H45DV 2** a poor fit for a residential replacement?

Avoid placing A. O. Smith HPA10-66H45DV 2** directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

What First Hour Rating or flow capacity does A. O. Smith HPA10-66H45DV 2** deliver?

With 83 gal FHR (+11 gal vs. 72 gal median), A. O. Smith HPA10-66H45DV 2** fits larger 3–5 person homes cleanly.

How do you verify manufacturing age and recall status on A. O. Smith HPA10-66H45DV 2**?

CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Does A. O. Smith HPA10-66H45DV 2** qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for A. O. Smith HPA10-66H45DV 2**. Closest peer in Hybrid/Electric Heat Pump is American HPA10266H045DV 2** (3.84 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks