Carnot Labs, Inc. N51 Water Heater Specifications (3.53 UEF)
With PD 4529563 certification, Carnot Labs, Inc. N51 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.53 UEF rating across its 47-gallon nominal tank, 75 gal First Hour Rating, standing #440 of 706 across 706 peers with Pass: +1.23 / +53.5% for May 6, 2029. Rated annual electricity draw of 1,404 kWh/yr equates to roughly $255/yr ($2,550 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Hubbell ME50HPT (3.46 UEF).
- Uniform Energy Factor
- 3.53 UEF
- Cohort UEF Rank
- #440 of 706
- First Hour Rating
- 75 gal
- Storage Volume
- 47 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.23 / +53.5%

ENERGY STAR certification places Carnot Labs, Inc. N51 at 3.53 UEF (#440 of 706; -0.17 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.
May 6, 2029 readiness: Carnot Labs, Inc. N51 stands +1.23 UEF (+53.5%) relative to 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,404 kWh/yr for Carnot Labs, Inc. N51 runs ~$255/yr vs. ~$978/yr for a 0.92 UEF electric tank.
State electric sensitivity for Carnot Labs, Inc. N51: 10-year operating spend spans $2,054 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,624 in Hawaii (Highest EIA State) (47.18 cents/kWh).
In the Hybrid/Electric Heat Pump tier, Hubbell ME50HPT (3.46 UEF, delta -0.07) and Noritz NHP50 (3.46 UEF, delta -0.07) bracket Carnot Labs, Inc. N51.
Where Does Carnot Labs, Inc. N51 Rank Against Peer Hybrid/Electric Heat Pump Units?
Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, Carnot Labs, Inc. N51 holds #440 of 706; inspect footprint, circuit load, and efficiency deltas here.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Carnot Labs, Inc. | 1 certified listing | ENERGY STAR PD 4529563 |
| Model Number | N51 | Draw pattern: High-Usage | N51 |
| Uniform Energy Factor (UEF) | 3.53 | -0.17 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 75 gal | +3 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,404 kWh/yr | +332 kWh/yr vs. 1,072 kWh/yr median | Est. $255/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 396.4% | -32.6 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 44.2" H x 18.9" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.9" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21.6 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-513A (GWP:630) | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Certification Date | 2026-02-10 | Certified 2026-02-10 | Markets: United States |
How Much Electricity Does N51 Use in Different States?
Estimated at $255/yr nationally (1,404 kWh/yr), 10-year utility spending for Carnot Labs, Inc. N51 shifts sharply between low-rate hydro and coastal grids.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $255/yr | $2,550 | $7,233 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $662/yr | $6,624 | $18,792 |
| California | 29.75 ¢/kWh ($0.2975) | $418/yr | $4,177 | $11,849 |
| Texas | 15.91 ¢/kWh ($0.1591) | $223/yr | $2,234 | $6,337 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $205/yr | $2,054 | $5,827 |
Does CPSC Flag Any Safety Notices on Carnot Labs, Inc. Units?
No open CPSC recall alerts appeared for Carnot Labs, Inc. as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See Serial Number Lookup.
Which Competing Hybrid/Electric Heat Pump Models Compare Closest to N51?
Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to Carnot Labs, Inc. N51's gallon capacity and 3.53 UEF efficiency.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Hubbell ME50HPT | Hybrid/Electric Heat Pump | 47 gal | 58 gal | 3.46 (-0.07) | 938 |
| Noritz NHP50 | Hybrid/Electric Heat Pump | 47 gal | 58 gal | 3.46 (-0.07) | 938 |
| VAUGHN THERMAL ME50HPT | Hybrid/Electric Heat Pump | 47 gal | 58 gal | 3.46 (-0.07) | 938 |
| 1HVAC ACIQ-50G-HP-WH | Hybrid/Electric Heat Pump | 47 gal | 69 gal | 3.75 (+0.22) | 855 |
| VAUGHN THERMAL ME50HPT-CN | Hybrid/Electric Heat Pump | 47 gal | 58 gal | 3.46 (-0.07) | 938 |
When Should Homeowners Skip Carnot Labs, Inc. N51 (Hybrid/Electric Heat Pump)?
Check Carnot Labs, Inc. N51's mechanical constraints—including utility space, Electric capacity, and Pass: +1.23 / +53.5% status—against typical residential installations.
Key Limitations & Exclusions
- Carnot Labs, Inc. N51 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Carnot Labs, Inc. N51 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Common Homeowner Questions for Carnot Labs, Inc. N51
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Will Carnot Labs, Inc. N51 stay compliant after the May 6, 2029 DOE standard takes effect?
Tested at 3.53 UEF, Carnot Labs, Inc. N51 shows Pass: +1.23 / +53.5% relative to May 6, 2029 federal DOE limits while placing #440 of 706 among 706 Hybrid/Electric Heat Pump peers like Hubbell ME50HPT.
Will Carnot Labs, Inc. N51 fit through a standard utility door and 72-inch basement ceiling?
Measuring 44.2 in. tall by 18.9 in. diameter, Carnot Labs, Inc. N51 notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.9" d). Reserve space above the jacket for T&P piping and anode removal.
Do existing utility hookups support Carnot Labs, Inc. N51 during replacement?
Electrical specs for Carnot Labs, Inc. N51 call for 240V at 21.6A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.
What is the estimated 10-year operating spend for Carnot Labs, Inc. N51?
At 18.16 cents/kWh national residential pricing, Carnot Labs, Inc. N51's 1,404 kWh/yr draw equals roughly $255 annually or $2,550 across a 10-year horizon (ranging from $205/yr in Washington hydro tiers up to $662/yr in Hawaii).
When is Carnot Labs, Inc. N51 a poor fit for a residential replacement?
Avoid placing Carnot Labs, Inc. N51 directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.
What First Hour Rating or flow capacity does Carnot Labs, Inc. N51 deliver?
With 75 gal FHR (+3 gal vs. 72 gal median), Carnot Labs, Inc. N51 fits larger 3–5 person homes cleanly.
How do you verify manufacturing age and recall status on Carnot Labs, Inc. N51?
Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Carnot Labs, Inc.; verify exact manufacturing week for Carnot Labs, Inc. N51 using the Serial Number Lookup tool.
Does Carnot Labs, Inc. N51 qualify for DOE HEAR incentives after 25C expired?
After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Carnot Labs, Inc. N51. Closest peer in Hybrid/Electric Heat Pump is Hubbell ME50HPT (3.46 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)