VAUGHN THERMAL ME50HPT Water Heater Specifications (3.46 UEF)
With PD 2649778 certification, VAUGHN THERMAL ME50HPT (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.46 UEF rating across its 47-gallon nominal tank, 58 gal First Hour Rating, standing #549 of 706 across 706 peers with Pass: +1.16 / +50.4% for May 6, 2029. Rated annual electricity draw of 938 kWh/yr equates to roughly $170/yr ($1,703 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Hubbell ME50HPT (3.46 UEF).
- Uniform Energy Factor
- 3.46 UEF
- Cohort UEF Rank
- #549 of 706
- First Hour Rating
- 58 gal
- Storage Volume
- 47 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.16 / +50.4%

ENERGY STAR certification places VAUGHN THERMAL ME50HPT at 3.46 UEF (#549 of 706; -0.24 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.
May 6, 2029 readiness: VAUGHN THERMAL ME50HPT stands +1.16 UEF (+50.4%) relative to 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 938 kWh/yr for VAUGHN THERMAL ME50HPT runs ~$170/yr vs. ~$641/yr for a 0.92 UEF electric tank.
State electric sensitivity for VAUGHN THERMAL ME50HPT: 10-year operating spend spans $1,372 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,425 in Hawaii (Highest EIA State) (47.18 cents/kWh).
In the Hybrid/Electric Heat Pump tier, Hubbell ME50HPT (3.46 UEF, at parity) and Noritz NHP50 (3.46 UEF, at parity) bracket VAUGHN THERMAL ME50HPT.
What Physical and Thermal Ratings Define VAUGHN THERMAL ME50HPT?
Positioning at #549 of 706 out of 706 Hybrid/Electric Heat Pump peers, VAUGHN THERMAL ME50HPT pairs measured UEF performance with specific clearance and wiring rules.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | VAUGHN THERMAL | 13 certified listings | ENERGY STAR PD 2649778 |
| Model Number | ME50HPT | Draw pattern: Medium-Usage | ME50HPT |
| Uniform Energy Factor (UEF) | 3.46 | -0.24 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 58 gal | -14 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 938 kWh/yr | -134 kWh/yr vs. 1,072 kWh/yr median | Est. $170/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 373% | -56.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 58.3" H x 28" D | Fits standard 72 in. basement/garage clearance; tight at 28 in. door (28" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 23 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Sound Pressure Level | 54 dBA | +5 dBA vs. 49 dBA median | Indoor placement check |
| Certification Date | 2023-08-30 | Certified 2023-08-30 | Markets: United States, Canada |
Why Do State Utility Rates Shift ME50HPT Running Costs?
Consuming 938 kWh annually puts VAUGHN THERMAL ME50HPT near $170/yr at US baseline tariffs, with multi-state EIA comparisons charted below.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $170/yr | $1,703 | $4,703 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $443/yr | $4,425 | $12,220 |
| California | 29.75 ¢/kWh ($0.2975) | $279/yr | $2,791 | $7,705 |
| Texas | 15.91 ¢/kWh ($0.1591) | $149/yr | $1,492 | $4,121 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $137/yr | $1,372 | $3,789 |
Have Any VAUGHN THERMAL Series Triggered CPSC Recalls?
SaferProducts screening on 2026-11-23 returned zero recall matches for VAUGHN THERMAL; confirm tank age separately using the rating-plate serial pattern. See Serial Number Lookup.
What Are 5 Direct Alternatives to VAUGHN THERMAL ME50HPT?
Homeowners cross-shopping VAUGHN THERMAL ME50HPT frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Hubbell ME50HPT | Hybrid/Electric Heat Pump | 47 gal | 58 gal | 3.46 (at parity) | 938 |
| Noritz NHP50 | Hybrid/Electric Heat Pump | 47 gal | 58 gal | 3.46 (at parity) | 938 |
| Carnot Labs, Inc. N51 | Hybrid/Electric Heat Pump | 47 gal | 75 gal | 3.53 (+0.07) | 1,404 |
| 1HVAC ACIQ-50G-HP-WH | Hybrid/Electric Heat Pump | 47 gal | 69 gal | 3.75 (+0.29) | 855 |
| ACIQ ACIQ-50G-HP-WH | Hybrid/Electric Heat Pump | 47 gal | 69 gal | 3.75 (+0.29) | 855 |
Who Is VAUGHN THERMAL ME50HPT Best For — and When Should You Pick Hubbell ME50HPT?
Evaluate whether VAUGHN THERMAL ME50HPT's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.
Key Limitations & Exclusions
- VAUGHN THERMAL ME50HPT needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 54 dBA; avoid mounting VAUGHN THERMAL ME50HPT directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Sizing, Efficiency & Recall Answers for VAUGHN THERMAL ME50HPT
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does VAUGHN THERMAL ME50HPT (3.46 UEF) compare to 2029 federal DOE floors?
Evaluated against May 6, 2029 10 CFR 430.32 thresholds, VAUGHN THERMAL ME50HPT records 3.46 UEF (Pass: +1.16 / +50.4%), placing #549 of 706 out of 706 certified Hybrid/Electric Heat Pump configurations.
Does VAUGHN THERMAL ME50HPT fit inside a tight hallway closet or low-headroom utility room?
VAUGHN THERMAL ME50HPT requires room for its 58.3 in. vertical shell and 28 in. diameter (fits standard 72 in. basement/garage clearance; tight at 28 in. door (28" d)), plus service access for annual sediment draining.
What power supply or fuel line specs govern VAUGHN THERMAL ME50HPT?
For VAUGHN THERMAL ME50HPT, plan a 240V circuit at 23A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.
What annual utility bill should homeowners budget for VAUGHN THERMAL ME50HPT?
Using 938 kWh/yr, VAUGHN THERMAL ME50HPT generates an estimated $170/yr electric bill at 18.16 cents/kWh (ranging from $137/yr in Washington hydro tiers up to $443/yr in Hawaii)—use the custom rate slider above for your utility tariff.
What are the main drawbacks of VAUGHN THERMAL ME50HPT (3.46 UEF)?
VAUGHN THERMAL ME50HPT requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or Hubbell ME50HPT.
What hot-water delivery rating governs VAUGHN THERMAL ME50HPT?
Rated for 58 gal FHR (-14 gal vs. 72 gal median), VAUGHN THERMAL ME50HPT prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.
Where do homeowners screen VAUGHN THERMAL ME50HPT for recalls and tank age?
Verified clean against 2026-11-23 CPSC recall feeds for VAUGHN THERMAL; use our browser-only serial decoder to inspect VAUGHN THERMAL ME50HPT's age and warranty window.
What alternative models sit closest to VAUGHN THERMAL ME50HPT in the Hybrid/Electric Heat Pump class?
Closest peer in Hybrid/Electric Heat Pump is Hubbell ME50HPT (3.46 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)