Noritz NHP50 Water Heater Specifications (3.46 UEF)
With PD 3798598 certification, Noritz NHP50 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.46 UEF rating across its 47-gallon nominal tank, 58 gal First Hour Rating, standing #549 of 706 across 706 peers with Pass: +1.16 / +50.4% for May 6, 2029. Rated annual electricity draw of 938 kWh/yr equates to roughly $170/yr ($1,703 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Hubbell ME50HPT (3.46 UEF).
- Uniform Energy Factor
- 3.46 UEF
- Cohort UEF Rank
- #549 of 706
- First Hour Rating
- 58 gal
- Storage Volume
- 47 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.16 / +50.4%

ENERGY STAR certification places Noritz NHP50 at 3.46 UEF (#549 of 706; -0.24 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.
May 6, 2029 readiness: Noritz NHP50 stands +1.16 UEF (+50.4%) relative to 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 938 kWh/yr for Noritz NHP50 runs ~$170/yr vs. ~$641/yr for a 0.92 UEF electric tank.
State electric sensitivity for Noritz NHP50: 10-year operating spend spans $1,372 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,425 in Hawaii (Highest EIA State) (47.18 cents/kWh).
In the Hybrid/Electric Heat Pump tier, Hubbell ME50HPT (3.46 UEF, at parity) and VAUGHN THERMAL ME50HPT (3.46 UEF, at parity) bracket Noritz NHP50.
How Do Noritz NHP50 Specs Compare to Hybrid/Electric Heat Pump Medians?
Noritz NHP50 places #549 of 706 across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Noritz | 23 certified listings | ENERGY STAR PD 3798598 |
| Model Number | NHP50 | Draw pattern: Medium-Usage | NHP50 |
| Uniform Energy Factor (UEF) | 3.46 | -0.24 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 58 gal | -14 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 938 kWh/yr | -134 kWh/yr vs. 1,072 kWh/yr median | Est. $170/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 373% | -56.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 58.3" H x 28" D | Fits standard 72 in. basement/garage clearance; tight at 28 in. door (28" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 23 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Sound Pressure Level | 54 dBA | +5 dBA vs. 49 dBA median | Indoor placement check |
| Certification Date | 2024-11-12 | Certified 2024-11-12 | Markets: United States, Canada |
What Does NHP50 Cost to Operate Across State Electricity Rates?
At 938 kWh/yr, Noritz NHP50 runs roughly $170/yr on the EIA national average tier under August 2026 Table 5.6.A rates.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $170/yr | $1,703 | $4,703 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $443/yr | $4,425 | $12,220 |
| California | 29.75 ¢/kWh ($0.2975) | $279/yr | $2,791 | $7,705 |
| Texas | 15.91 ¢/kWh ($0.1591) | $149/yr | $1,492 | $4,121 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $137/yr | $1,372 | $3,789 |
Are There Active CPSC Safety Recalls for Noritz Water Heaters?
Zero active CPSC recalls matched Noritz in our 2026-11-23 SaferProducts sweep; verify your individual tank date code via our lookup tool. See Serial Number Lookup.
Which Certified Water Heaters Match NHP50 Most Closely?
These 5 competing Hybrid/Electric Heat Pump units sit nearest to Noritz NHP50 by storage capacity and 3.46 UEF rating.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Hubbell ME50HPT | Hybrid/Electric Heat Pump | 47 gal | 58 gal | 3.46 (at parity) | 938 |
| VAUGHN THERMAL ME50HPT | Hybrid/Electric Heat Pump | 47 gal | 58 gal | 3.46 (at parity) | 938 |
| Carnot Labs, Inc. N51 | Hybrid/Electric Heat Pump | 47 gal | 75 gal | 3.53 (+0.07) | 1,404 |
| 1HVAC ACIQ-50G-HP-WH | Hybrid/Electric Heat Pump | 47 gal | 69 gal | 3.75 (+0.29) | 855 |
| VAUGHN THERMAL ME50HPT-CN | Hybrid/Electric Heat Pump | 47 gal | 58 gal | 3.46 (at parity) | 938 |
Who Is Noritz NHP50 Best For — and When Should You Pick Hubbell ME50HPT?
Evaluate whether Noritz NHP50's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.
Key Limitations & Exclusions
- Noritz NHP50 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 54 dBA; avoid mounting Noritz NHP50 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
What Are the Key Questions About Noritz NHP50?
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does Noritz NHP50 (3.46 UEF) compare to 2029 federal DOE floors?
Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Noritz NHP50 records 3.46 UEF (Pass: +1.16 / +50.4%), placing #549 of 706 out of 706 certified Hybrid/Electric Heat Pump configurations.
Does Noritz NHP50 fit inside a tight hallway closet or low-headroom utility room?
Noritz NHP50 requires room for its 58.3 in. vertical shell and 28 in. diameter (fits standard 72 in. basement/garage clearance; tight at 28 in. door (28" d)), plus service access for annual sediment draining.
What power supply or fuel line specs govern Noritz NHP50?
For Noritz NHP50, plan a 240V circuit at 23A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.
What annual utility bill should homeowners budget for Noritz NHP50?
Using 938 kWh/yr, Noritz NHP50 generates an estimated $170/yr electric bill at 18.16 cents/kWh (ranging from $137/yr in Washington hydro tiers up to $443/yr in Hawaii)—use the custom rate slider above for your utility tariff.
What are the main drawbacks of Noritz NHP50 (3.46 UEF)?
Noritz NHP50 requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or Hubbell ME50HPT.
What hot-water delivery rating governs Noritz NHP50?
Rated for 58 gal FHR (-14 gal vs. 72 gal median), Noritz NHP50 prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.
Where do homeowners screen Noritz NHP50 for recalls and tank age?
Verified clean against 2026-11-23 CPSC recall feeds for Noritz; use our browser-only serial decoder to inspect Noritz NHP50's age and warranty window.
What alternative models sit closest to Noritz NHP50 in the Hybrid/Electric Heat Pump class?
Closest peer in Hybrid/Electric Heat Pump is Hubbell ME50HPT (3.46 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)