VAUGHN THERMAL ME50HPT-CN Water Heater Specifications (3.46 UEF)
In the 706-unit Hybrid/Electric Heat Pump class, VAUGHN THERMAL ME50HPT-CN (Electric) achieves a certified 3.46 UEF rating across its 47-gallon nominal tank, 58 gal First Hour Rating (rank #549 of 706, PD 3478044) and verifies as Pass: +1.16 / +50.4% for 2029 DOE floors. Rated annual electricity draw of 938 kWh/yr equates to roughly $170/yr ($1,703 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Hubbell ME50HPT (3.46 UEF).
- Uniform Energy Factor
- 3.46 UEF
- Cohort UEF Rank
- #549 of 706
- First Hour Rating
- 58 gal
- Storage Volume
- 47 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.16 / +50.4%

VAUGHN THERMAL ME50HPT-CN records 3.46 UEF efficiency, putting it #549 of 706 among 706 Hybrid/Electric Heat Pump peers.
10 CFR 430.32(d)(2) compliance: VAUGHN THERMAL ME50HPT-CN exceeds 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.16 UEF (+50.4%). At EIA August 2026 national rates (18.16 cents/kWh), 938 kWh/yr for VAUGHN THERMAL ME50HPT-CN runs ~$170/yr vs. ~$641/yr for a 0.92 UEF electric tank.
State electric sensitivity for VAUGHN THERMAL ME50HPT-CN: 10-year operating spend spans $1,372 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,425 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Competing options beside VAUGHN THERMAL ME50HPT-CN (3.46 UEF) are Hubbell ME50HPT (3.46 UEF, at parity) and Noritz NHP50 (3.46 UEF, at parity).
Which Specs Set VAUGHN THERMAL ME50HPT-CN Apart From Cohort Averages?
Ranked #549 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, VAUGHN THERMAL ME50HPT-CN is evaluated row by row below against category medians.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | VAUGHN THERMAL | 13 certified listings | ENERGY STAR PD 3478044 |
| Model Number | ME50HPT-CN | Draw pattern: Medium-Usage | ME50HPT-CN |
| Uniform Energy Factor (UEF) | 3.46 | -0.24 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 58 gal | -14 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 938 kWh/yr | -134 kWh/yr vs. 1,072 kWh/yr median | Est. $170/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 373% | -56.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 58.3" H x 28" D | Fits standard 72 in. basement/garage clearance; tight at 28 in. door (28" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 23 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Sound Pressure Level | 54 dBA | +5 dBA vs. 49 dBA median | Indoor placement check |
| Certification Date | 2024-08-13 | Certified 2024-08-13 | Markets: United States, Canada |
How Do Regional kWh Prices Impact ME50HPT-CN Over 10 Years?
Using EIA Table 5.6.A benchmarks, VAUGHN THERMAL ME50HPT-CN's 938 kWh/yr draw translates to roughly $170/yr on typical US residential bills.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $170/yr | $1,703 | $4,703 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $443/yr | $4,425 | $12,220 |
| California | 29.75 ¢/kWh ($0.2975) | $279/yr | $2,791 | $7,705 |
| Texas | 15.91 ¢/kWh ($0.1591) | $149/yr | $1,492 | $4,121 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $137/yr | $1,372 | $3,789 |
What Should VAUGHN THERMAL Owners Check in CPSC Recall Logs?
The 2026-11-23 CPSC recall sweep recorded zero brand matches for VAUGHN THERMAL; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.
How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?
Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Hubbell ME50HPT | Hybrid/Electric Heat Pump | 47 gal | 58 gal | 3.46 (at parity) | 938 |
| Noritz NHP50 | Hybrid/Electric Heat Pump | 47 gal | 58 gal | 3.46 (at parity) | 938 |
| Carnot Labs, Inc. N51 | Hybrid/Electric Heat Pump | 47 gal | 75 gal | 3.53 (+0.07) | 1,404 |
| 1HVAC ACIQ-50G-HP-WH | Hybrid/Electric Heat Pump | 47 gal | 69 gal | 3.75 (+0.29) | 855 |
| ACIQ ACIQ-50G-HP-WH | Hybrid/Electric Heat Pump | 47 gal | 69 gal | 3.75 (+0.29) | 855 |
Which Home Setups Are NOT a Fit for VAUGHN THERMAL ME50HPT-CN?
Comparing VAUGHN THERMAL ME50HPT-CN against Hubbell ME50HPT requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.
Key Limitations & Exclusions
- VAUGHN THERMAL ME50HPT-CN needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 54 dBA; avoid mounting VAUGHN THERMAL ME50HPT-CN directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Frequently Asked Technical Questions: VAUGHN THERMAL ME50HPT-CN
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does VAUGHN THERMAL ME50HPT-CN score under 10 CFR 430.32 May 2029 water heater minimums?
Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; VAUGHN THERMAL ME50HPT-CN logs 3.46 UEF (Pass: +1.16 / +50.4%) within the 706-unit Hybrid/Electric Heat Pump group.
What physical clearance dimensions apply when installing VAUGHN THERMAL ME50HPT-CN?
With a 58.3 in. height and 28 in. diameter, VAUGHN THERMAL ME50HPT-CN fits spaces matching: fits standard 72 in. basement/garage clearance; tight at 28 in. door (28" d), plus 6–12 in. above for plumbing shutoffs.
What 240V circuit or IFGC fuel line capacity fits VAUGHN THERMAL ME50HPT-CN?
Powered via 240V at 23A max, VAUGHN THERMAL ME50HPT-CN requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.
How do state electricity prices change annual costs for VAUGHN THERMAL ME50HPT-CN?
Annual electric spend for VAUGHN THERMAL ME50HPT-CN (938 kWh/yr) averages $170/yr nationwide (ranging from $137/yr in Washington hydro tiers up to $443/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.
What homeowner setups should avoid choosing VAUGHN THERMAL ME50HPT-CN?
Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on VAUGHN THERMAL ME50HPT-CN.
Is VAUGHN THERMAL ME50HPT-CN sized adequately for a 2-to-4-person household?
ENERGY STAR certifies VAUGHN THERMAL ME50HPT-CN at 58 gal First Hour Rating (-14 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.
Does VAUGHN THERMAL have active CPSC SaferProducts notices affecting ME50HPT-CN?
Zero CPSC recall alerts matched VAUGHN THERMAL (2026-11-23 check). Keep your VAUGHN THERMAL ME50HPT-CN serial code handy to track standard 6-to-12-year OEM warranty coverage.
Which competing water heater matches VAUGHN THERMAL ME50HPT-CN (3.46 UEF) most closely?
State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for VAUGHN THERMAL ME50HPT-CN. Closest peer in Hybrid/Electric Heat Pump is Hubbell ME50HPT (3.46 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)