Friedrich 12PROG 50-100U FD HE EC3 Water Heater Specifications (0.89 UEF)
With PD 3555208 certification, Friedrich 12PROG 50-100U FD HE EC3 (Gas-fired Storage Residential-duty Commercial, Natural Gas) achieves a certified 0.89 UEF rating across its 50-gallon nominal tank, 167 gal First Hour Rating, standing #8 of 71 across 71 peers with Pass: +0.31 / +53.4% for May 6, 2029. Annual fuel cost depends on regional gas/fuel tariffs and verify 72 in. vertical headroom; clears 28 in. utility doorway (21.8" d). Closest certified alternative is Rheem ECE G50-100U CN HE EC3 (0.89 UEF).
- Uniform Energy Factor
- 0.89 UEF
- Cohort UEF Rank
- #8 of 71
- First Hour Rating
- 167 gal
- Storage Volume
- 50 gal
- Fuel / Type
- Natural Gas / Gas-fired Storage Residential-duty Commercial
- DOE 2029 Rule Status
- Pass: +0.31 / +53.4%

ENERGY STAR certification places Friedrich 12PROG 50-100U FD HE EC3 at 0.89 UEF (#8 of 71; +0.01 UEF vs. 0.88 UEF median) in Gas-fired Storage Residential-duty Commercial.
Friedrich 12prog 50-100u fd he ec3 stores 50 gal nominal; 167 gal first hour rating (+31 gal vs. 136 gal median); verify 72 in. vertical headroom; clears 28 in. utility doorway (21.8" d).
In the Gas-fired Storage Residential-duty Commercial tier, Rheem ECE G50-100U CN HE EC3 (0.89 UEF, at parity) and Richmond 12GUH50-100F* (0.89 UEF, at parity) bracket Friedrich 12PROG 50-100U FD HE EC3.
How Do Friedrich 12PROG 50-100U FD HE EC3 Specs Compare to Gas-fired Storage Residential-duty Commercial Medians?
Friedrich 12PROG 50-100U FD HE EC3 places #8 of 71 across 71 certified Gas-fired Storage Residential-duty Commercial configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Friedrich | 61 certified listings | ENERGY STAR PD 3555208 |
| Model Number | 12PROG 50-100U FD HE EC3 | Draw pattern: High-Usage | 12PROG 50-100U FD HE EC3 |
| Uniform Energy Factor (UEF) | 0.89 | +0.01 UEF vs. 0.88 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 167 gal | +31 gal vs. 136 gal median | 10 CFR 430 Recovery Test |
| Thermal Recovery Efficiency | 96% | +1.0 pts vs. 95.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 65.5" H x 21.8" D | Verify 72 in. vertical headroom; clears 28 in. utility doorway (21.8" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 7 A max | 120V AC ignition/fan + gas piping check | NEC / Branch circuit check |
| Certification Date | 2024-11-04 | Certified 2024-11-04 | Markets: United States |
Are There Active CPSC Safety Recalls for Friedrich Water Heaters?
Zero active CPSC recalls matched Friedrich in our 2026-11-23 SaferProducts sweep; verify your individual tank date code via our lookup tool. See Serial Number Lookup.
Which Certified Water Heaters Match 12PROG 50-100U FD HE EC3 Most Closely?
These 5 competing Gas-fired Storage Residential-duty Commercial units sit nearest to Friedrich 12PROG 50-100U FD HE EC3 by storage capacity and 0.89 UEF rating.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Rheem ECE G50-100U CN HE EC3 | Gas-fired Storage Residential-duty Commercial | 50 gal | 167 gal | 0.89 (at parity) | — |
| Richmond 12GUH50-100F* | Gas-fired Storage Residential-duty Commercial | 50 gal | 167 gal | 0.89 (at parity) | — |
| Ruud PROU G50-100* RU HE EC3 | Gas-fired Storage Residential-duty Commercial | 50 gal | 167 gal | 0.89 (at parity) | — |
| A. O. Smith HDHE-50 4** | Gas-fired Storage Residential-duty Commercial | 49 gal | 118 gal | 0.88 (-0.01) | — |
| Rheem PROP G50-100* CN HE EC3 | Gas-fired Storage Residential-duty Commercial | 50 gal | 167 gal | 0.89 (at parity) | — |
What Installation Caveats Apply Before Buying Friedrich 12PROG 50-100U FD HE EC3?
Even high-UEF units like Friedrich 12PROG 50-100U FD HE EC3 (0.89 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.
Key Limitations & Exclusions
- Friedrich 12PROG 50-100U FD HE EC3 logs 0.89 UEF (Pass: +0.31 / +53.4%); check May 6, 2029 10 CFR 430.32 transition status.
- Drain tank sediment yearly and inspect Friedrich 12PROG 50-100U FD HE EC3's sacrificial anode rod every 4–6 years.
- Peak simultaneous draws exceeding 167 gal will deplete stored recovery capacity.
Which Option Fits Your Situation?
What Are the Key Questions About Friedrich 12PROG 50-100U FD HE EC3?
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Is Friedrich 12PROG 50-100U FD HE EC3 eligible for continued manufacture past May 6, 2029?
At 0.89 UEF, Friedrich 12PROG 50-100U FD HE EC3 achieves Pass: +0.31 / +53.4% for the 2029 DOE standard and stands #8 of 71 against Rheem ECE G50-100U CN HE EC3 and Richmond 12GUH50-100F*.
How tall and wide is Friedrich 12PROG 50-100U FD HE EC3, and what service clearance is needed?
Physical dimensions for Friedrich 12PROG 50-100U FD HE EC3 are 65.5 in. height and 21.8 in. diameter (verify 72 in. vertical headroom; clears 28 in. utility doorway (21.8" d)); verify stair turns and drain pan width before delivery.
Will Friedrich 12PROG 50-100U FD HE EC3 require upgrading household electrical panels or gas piping?
Check Natural Gas piping and venting for Friedrich 12PROG 50-100U FD HE EC3 (120V AC ignition/fan + gas piping check); undersized 1/2 in. gas branches cause peak-demand ignition lockouts on high-input burners.
Is Friedrich 12PROG 50-100U FD HE EC3 economical to operate at 18.16 cents/kWh US electric rates?
Fuel bills for Friedrich 12PROG 50-100U FD HE EC3 (Natural Gas, 0.89 UEF) hinge on household gallon demand and local gas utility tariffs compared with Rheem ECE G50-100U CN HE EC3.
Which installation bottlenecks limit Friedrich 12PROG 50-100U FD HE EC3?
Check local 10 CFR 430.32(d)(2) phase-in timing (Pass: +0.31 / +53.4%) and physical doorway clearances before choosing Friedrich 12PROG 50-100U FD HE EC3 over Rheem ECE G50-100U CN HE EC3.
How does Friedrich 12PROG 50-100U FD HE EC3 handle simultaneous showers and laundry?
Delivering 167 gal in the first hour (+31 gal vs. 136 gal median), Friedrich 12PROG 50-100U FD HE EC3 combines 50 gal tank storage with rapid burner/element recovery.
How long is the warranty on Friedrich 12PROG 50-100U FD HE EC3 and how do you decode its serial?
CPSC records show 0 active plumbing recalls for Friedrich as of 2026-11-23. Confirm install proof and serial manufacture year on Friedrich 12PROG 50-100U FD HE EC3 before calling service.
How do 2026 post-OBBBA rebates affect buying Friedrich 12PROG 50-100U FD HE EC3?
Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Gas-fired Storage Residential-duty Commercial is Rheem ECE G50-100U CN HE EC3 (0.89 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)