Skip to main content
ENERGY STAR water heater model · PD 2408619

Rheem ECE G50-100U CN HE EC3 Water Heater Specifications (0.89 UEF)

In the 71-unit Gas-fired Storage Residential-duty Commercial class, Rheem ECE G50-100U CN HE EC3 (Natural Gas) achieves a certified 0.89 UEF rating across its 50-gallon nominal tank, 167 gal First Hour Rating (rank #8 of 71, PD 2408619) and verifies as Pass: +0.31 / +53.4% for 2029 DOE floors. Annual fuel cost depends on regional gas/fuel tariffs and verify 72 in. vertical headroom; clears 28 in. utility doorway (21.8" d). Closest certified alternative is Friedrich 12PROG 50-100P FD HE EC3 (0.89 UEF).

Uniform Energy Factor
0.89 UEF
Cohort UEF Rank
#8 of 71
First Hour Rating
167 gal
Storage Volume
50 gal
Fuel / Type
Natural Gas / Gas-fired Storage Residential-duty Commercial
DOE 2029 Rule Status
Pass: +0.31 / +53.4%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Gas-fired Storage Residential-duty Commercial UEF Efficiency Distribution (71 Certified Units)Distribution of certified UEF ratings across 71 units in Gas-fired Storage Residential-duty Commercial, marking Rheem ECE G50-100U CN HE EC3 at 0.89 UEF.1012726610.86 UEF0.93 UEFMedian 0.882029 min 0.58Rheem ECE G50-100U CN HE EC3: 0.89
Gas-fired Storage Residential-duty Commercial UEF Efficiency Distribution (71 Certified Units). Highlighted pin shows Rheem ECE G50-100U CN HE EC3 relative to the cohort median.
Efficiency comparison & rule summary

Rheem ECE G50-100U CN HE EC3 records 0.89 UEF efficiency, putting it #8 of 71 among 71 Gas-fired Storage Residential-duty Commercial peers.

Rheem ece g50-100u cn he ec3 stores 50 gal nominal; 167 gal first hour rating (+31 gal vs. 136 gal median); verify 72 in. vertical headroom; clears 28 in. utility doorway (21.8" d).

Competing options beside Rheem ECE G50-100U CN HE EC3 (0.89 UEF) are Friedrich 12PROG 50-100P FD HE EC3 (0.89 UEF, at parity) and Richmond 12GUH50-100F* (0.89 UEF, at parity).

Where Does Rheem ECE G50-100U CN HE EC3 Rank Against Peer Gas-fired Storage Residential-duty Commercial Units?

Audited against 71 ENERGY STAR Gas-fired Storage Residential-duty Commercial listings, Rheem ECE G50-100U CN HE EC3 holds #8 of 71; inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 71 ENERGY STAR Gas-fired Storage Residential-duty Commercial peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRheem236 certified listingsENERGY STAR PD 2408619
Model NumberECE G50-100U CN HE EC3Draw pattern: High-UsageECE G50-100U CN HE EC3
Uniform Energy Factor (UEF)0.89+0.01 UEF vs. 0.88 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)167 gal+31 gal vs. 136 gal median10 CFR 430 Recovery Test
Thermal Recovery Efficiency96%+1.0 pts vs. 95.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)65.5" H x 21.8" DVerify 72 in. vertical headroom; clears 28 in. utility doorway (21.8" D)Doorway & ceiling check
Electrical Circuit Requirements7 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2024-11-04Certified 2024-11-04Markets: United States, Canada
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Does CPSC Flag Any Safety Notices on Rheem Units?

Checking 2026-11-23 SaferProducts data shows 4 notices mentioning Rheem; always cross-reference affected serial prefixes before ordering components. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #16177 (2016-05-26): Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot (CPSC Notice)
  • Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
  • Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

Which Competing Gas-fired Storage Residential-duty Commercial Models Compare Closest to ECE G50-100U CN HE EC3?

Compare five nearby ENERGY STAR Gas-fired Storage Residential-duty Commercial options matched closely to Rheem ECE G50-100U CN HE EC3's gallon capacity and 0.89 UEF efficiency.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich 12PROG 50-100P FD HE EC3 Gas-fired Storage Residential-duty Commercial 50 gal 167 gal 0.89 (at parity) —
Richmond 12GUH50-100F* Gas-fired Storage Residential-duty Commercial 50 gal 167 gal 0.89 (at parity) —
Ruud PROU G50-100* RU HE EC3 Gas-fired Storage Residential-duty Commercial 50 gal 167 gal 0.89 (at parity) —
A. O. Smith HDHE-50 4** Gas-fired Storage Residential-duty Commercial 49 gal 118 gal 0.88 (-0.01) —
Friedrich 12PROG 50-100U FD HE EC3 Gas-fired Storage Residential-duty Commercial 50 gal 167 gal 0.89 (at parity) —

When Should Homeowners Skip Rheem ECE G50-100U CN HE EC3 (Gas-fired Storage Residential-duty Commercial)?

Check Rheem ECE G50-100U CN HE EC3's mechanical constraints—including utility space, Natural Gas capacity, and Pass: +0.31 / +53.4% status—against typical residential installations.

Key Limitations & Exclusions

  • Rheem ECE G50-100U CN HE EC3 logs 0.89 UEF (Pass: +0.31 / +53.4%); check May 6, 2029 10 CFR 430.32 transition status.
  • Drain tank sediment yearly and inspect Rheem ECE G50-100U CN HE EC3's sacrificial anode rod every 4–6 years.
  • Peak simultaneous draws exceeding 167 gal will deplete stored recovery capacity.

Which Option Fits Your Situation?

Direct Footprint Replacement for Rheem ECE G50-100U CN HE EC3 Strong Fit — Matches existing plumbing and vent clearances.
2026 Post-OBBBA Rebate Buyers Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like Friedrich 12PROG 50-100P FD HE EC3.
Very Hard Well Water (>10.5 GPG) Add Softener / Flush — Schedule 6-month tank sediment drains.

Common Homeowner Questions for Rheem ECE G50-100U CN HE EC3

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will Rheem ECE G50-100U CN HE EC3 stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 0.89 UEF, Rheem ECE G50-100U CN HE EC3 shows Pass: +0.31 / +53.4% relative to May 6, 2029 federal DOE limits while placing #8 of 71 among 71 Gas-fired Storage Residential-duty Commercial peers like Friedrich 12PROG 50-100P FD HE EC3.

Will Rheem ECE G50-100U CN HE EC3 fit through a standard utility door and 72-inch basement ceiling?

Measuring 65.5 in. tall by 21.8 in. diameter, Rheem ECE G50-100U CN HE EC3 notes: verify 72 in. vertical headroom; clears 28 in. utility doorway (21.8" d). Reserve space above the jacket for T&P piping and anode removal.

Do existing utility hookups support Rheem ECE G50-100U CN HE EC3 during replacement?

Fueled by Natural Gas, Rheem ECE G50-100U CN HE EC3 specifies: 120V AC ignition/fan + gas piping check. Always measure developed gas pipe length because high-BTU burners frequently require 3/4 in. or 1 in. Schedule 40 supply.

What is the estimated 10-year operating spend for Rheem ECE G50-100U CN HE EC3?

Because Rheem ECE G50-100U CN HE EC3 burns Natural Gas at 0.89 UEF, operating bills track local natural gas or propane pricing rather than kWh tariffs across 71 peers.

When is Rheem ECE G50-100U CN HE EC3 a poor fit for a residential replacement?

Avoid Rheem ECE G50-100U CN HE EC3 if household peak demand surpasses 167 gal per hour or if state DOE HEAR incentives require >=2.30 UEF heat-pump equipment.

What First Hour Rating or flow capacity does Rheem ECE G50-100U CN HE EC3 deliver?

With 167 gal FHR (+31 gal vs. 136 gal median), Rheem ECE G50-100U CN HE EC3 fits larger 3–5 person homes cleanly.

How do you verify manufacturing age and recall status on Rheem ECE G50-100U CN HE EC3?

CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Does Rheem ECE G50-100U CN HE EC3 qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Rheem ECE G50-100U CN HE EC3. Closest peer in Gas-fired Storage Residential-duty Commercial is Friedrich 12PROG 50-100P FD HE EC3 (0.89 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks