Skip to main content
ENERGY STAR water heater model · PD 2408617

Richmond 12GUH50-100F* Water Heater Specifications (0.89 UEF)

Engineered as a Natural Gas, Propane Gas-fired Storage Residential-duty Commercial unit, Richmond 12GUH50-100F* achieves a certified 0.89 UEF rating across its 50-gallon nominal tank, 167 gal First Hour Rating and ranks #8 of 71 in its 71-model cohort (PD 2408617), recording Pass: +0.31 / +53.4% under 2029 DOE rules. Annual fuel cost depends on regional gas/fuel tariffs and verify 72 in. vertical headroom; clears 28 in. utility doorway (21.8" d). Closest certified alternative is Friedrich 12PROG 50-100P FD HE EC3 (0.89 UEF).

Uniform Energy Factor
0.89 UEF
Cohort UEF Rank
#8 of 71
First Hour Rating
167 gal
Storage Volume
50 gal
Fuel / Type
Natural Gas, Propane / Gas-fired Storage Residential-duty Commercial
DOE 2029 Rule Status
Pass: +0.31 / +53.4%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Gas-fired Storage Residential-duty Commercial UEF Efficiency Distribution (71 Certified Units)Distribution of certified UEF ratings across 71 units in Gas-fired Storage Residential-duty Commercial, marking Richmond 12GUH50-100F* at 0.89 UEF.1012726610.86 UEF0.93 UEFMedian 0.882029 min 0.58Richmond 12GUH50-100F*: 0.89
Gas-fired Storage Residential-duty Commercial UEF Efficiency Distribution (71 Certified Units). Highlighted pin shows Richmond 12GUH50-100F* relative to the cohort median.
Efficiency comparison & rule summary

Within the 71-unit Gas-fired Storage Residential-duty Commercial cohort, Richmond 12GUH50-100F* logs 0.89 UEF and ranks #8 of 71.

Richmond 12guh50-100f* stores 50 gal nominal; 167 gal first hour rating (+31 gal vs. 136 gal median); verify 72 in. vertical headroom; clears 28 in. utility doorway (21.8" d).

Cross-shopping Richmond 12GUH50-100F* (0.89 UEF)? Check Friedrich 12PROG 50-100P FD HE EC3 (0.89 UEF, at parity) and Rheem ECE G50-100U CN HE EC3 (0.89 UEF, at parity).

Which Specs Set Richmond 12GUH50-100F* Apart From Cohort Averages?

Ranked #8 of 71 inside the 71-model Gas-fired Storage Residential-duty Commercial cohort, Richmond 12GUH50-100F* is evaluated row by row below against category medians.

Certified model attributes compared against 71 ENERGY STAR Gas-fired Storage Residential-duty Commercial peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRichmond80 certified listingsENERGY STAR PD 2408617
Model Number12GUH50-100F*Draw pattern: High-Usage12GUH50-100F*
Uniform Energy Factor (UEF)0.89+0.01 UEF vs. 0.88 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)167 gal+31 gal vs. 136 gal median10 CFR 430 Recovery Test
Thermal Recovery Efficiency96%+1.0 pts vs. 95.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)65.5" H x 21.8" DVerify 72 in. vertical headroom; clears 28 in. utility doorway (21.8" D)Doorway & ceiling check
Electrical Circuit Requirements7 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2024-11-04Certified 2024-11-04Markets: United States
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should Richmond Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC recall sweep recorded zero brand matches for Richmond; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.

How Do Five Nearby Gas-fired Storage Residential-duty Commercial Models Stack Up?

Five alternative Gas-fired Storage Residential-duty Commercial units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich 12PROG 50-100P FD HE EC3 Gas-fired Storage Residential-duty Commercial 50 gal 167 gal 0.89 (at parity) —
Rheem ECE G50-100U CN HE EC3 Gas-fired Storage Residential-duty Commercial 50 gal 167 gal 0.89 (at parity) —
Ruud PROU G50-100* RU HE EC3 Gas-fired Storage Residential-duty Commercial 50 gal 167 gal 0.89 (at parity) —
A. O. Smith HDHE-50 4** Gas-fired Storage Residential-duty Commercial 49 gal 118 gal 0.88 (-0.01) —
Friedrich 12PROG 50-100U FD HE EC3 Gas-fired Storage Residential-duty Commercial 50 gal 167 gal 0.89 (at parity) —

What Are the Limitations of Richmond 12GUH50-100F* and Who Should Not Install It?

Before ordering Richmond 12GUH50-100F* (Gas-fired Storage Residential-duty Commercial, 0.89 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

Key Limitations & Exclusions

  • Richmond 12GUH50-100F* logs 0.89 UEF (Pass: +0.31 / +53.4%); check May 6, 2029 10 CFR 430.32 transition status.
  • Drain tank sediment yearly and inspect Richmond 12GUH50-100F*'s sacrificial anode rod every 4–6 years.
  • Peak simultaneous draws exceeding 167 gal will deplete stored recovery capacity.

Which Option Fits Your Situation?

Direct Footprint Replacement for Richmond 12GUH50-100F* Strong Fit — Matches existing plumbing and vent clearances.
2026 Post-OBBBA Rebate Buyers Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like Friedrich 12PROG 50-100P FD HE EC3.
Very Hard Well Water (>10.5 GPG) Add Softener / Flush — Schedule 6-month tank sediment drains.

Frequently Asked Technical Questions: Richmond 12GUH50-100F*

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does Richmond 12GUH50-100F* pass the May 6, 2029 federal DOE efficiency rule?

Richmond 12GUH50-100F* carries a verified 0.89 UEF rating (Pass: +0.31 / +53.4%), ranking #8 of 71 across 71 ENERGY STAR Gas-fired Storage Residential-duty Commercial models under 10 CFR 430.32.

What doorway width and ceiling height does Richmond 12GUH50-100F* need?

Richmond 12GUH50-100F* stands 65.5 in. high with a 21.8 in. diameter; verify 72 in. vertical headroom; clears 28 in. utility doorway (21.8" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

What gas pipe size or electrical breaker does Richmond 12GUH50-100F* require?

Richmond 12GUH50-100F* runs on Natural Gas, Propane (120V AC ignition/fan + gas piping check). Upgrading from a 40K tank to 199K BTU/h tankless demand requires checking IFGC Table 402.4(2), since 1/2 in. iron pipe drops below 199 CFH past 10 ft.

How much electricity or energy does Richmond 12GUH50-100F* cost per year to run?

ENERGY STAR rates Richmond 12GUH50-100F* as a Natural Gas, Propane heater (0.89 UEF) without an electric kWh figure; annual fuel spend depends on local therm rates and Gas-fired Storage Residential-duty Commercial draw.

Who should NOT install Richmond 12GUH50-100F*, and what are its limits?

Richmond 12GUH50-100F* (0.89 UEF) is not suited for multi-bath marathon draws exceeding its 167 gal capacity or buyers prioritizing May 6, 2029 high-UEF HPWH rebates.

How many bathrooms or people can Richmond 12GUH50-100F* serve at peak demand?

Richmond 12GUH50-100F* achieves a 167 gal First Hour Rating (+31 gal vs. 136 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

Are there CPSC safety recalls or serial checks for Richmond 12GUH50-100F*?

No active CPSC recalls matched Richmond as of 2026-11-23. Always decode the serial tag on Richmond 12GUH50-100F* because OEM tank/exchanger warranties span 6–12 years.

What 2026 rebates apply to Richmond 12GUH50-100F*, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Gas-fired Storage Residential-duty Commercial is Friedrich 12PROG 50-100P FD HE EC3 (0.89 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks