Friedrich PROH40 T2 FD350UM Water Heater Specifications (3.5 UEF)
The Friedrich PROH40 T2 FD350UM (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.5 UEF rating across its 36-gallon nominal tank, 60 gal First Hour Rating, ranking #481 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 3994195). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.20 / +52.2%. Rated annual electricity draw of 879 kWh/yr equates to roughly $160/yr ($1,596 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Rheem CPROPH40 T2 RH350BM (3.5 UEF).
- Uniform Energy Factor
- 3.5 UEF
- Cohort UEF Rank
- #481 of 706
- First Hour Rating
- 60 gal
- Storage Volume
- 36 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.20 / +52.2%

Friedrich PROH40 T2 FD350UM (3.5 UEF) ranks #481 of 706 Hybrid/Electric Heat Pump models — 64-way tie; more efficient than 22.9% of Hybrid/Electric Heat Pump models, -0.20 UEF below the 3.70 UEF median.
Federal 2029 margin for Friedrich PROH40 T2 FD350UM: +1.20 UEF (+52.2%) vs. 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 879 kWh/yr for Friedrich PROH40 T2 FD350UM runs ~$160/yr vs. ~$607/yr for a 0.92 UEF electric tank.
State electric sensitivity for Friedrich PROH40 T2 FD350UM: 10-year operating spend spans $1,286 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,147 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Peer comparison: Friedrich PROH40 T2 FD350UM (3.5 UEF) compares closely with Rheem CPROPH40 T2 RH350BM (3.5 UEF, at parity) and Ruud PRO H40 T2 RU310BM (3.5 UEF, at parity).
What Physical and Thermal Ratings Define Friedrich PROH40 T2 FD350UM?
Positioning at #481 of 706 out of 706 Hybrid/Electric Heat Pump peers, Friedrich PROH40 T2 FD350UM pairs measured UEF performance with specific clearance and wiring rules.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Friedrich | 61 certified listings | ENERGY STAR PD 3994195 |
| Model Number | PROH40 T2 FD350UM | Draw pattern: Medium-Usage | PROH40 T2 FD350UM |
| Uniform Energy Factor (UEF) | 3.5 | -0.20 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 60 gal | -12 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 879 kWh/yr | -193 kWh/yr vs. 1,072 kWh/yr median | Est. $160/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 423% | -6.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 62.3" H x 20.3" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: United States |
Why Do State Utility Rates Shift PROH40 T2 FD350UM Running Costs?
Consuming 879 kWh annually puts Friedrich PROH40 T2 FD350UM near $160/yr at US baseline tariffs, with multi-state EIA comparisons charted below.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $160/yr | $1,596 | $4,476 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $415/yr | $4,147 | $11,630 |
| California | 29.75 ¢/kWh ($0.2975) | $262/yr | $2,615 | $7,333 |
| Texas | 15.91 ¢/kWh ($0.1591) | $140/yr | $1,398 | $3,922 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $129/yr | $1,286 | $3,606 |
Have Any Friedrich Series Triggered CPSC Recalls?
SaferProducts screening on 2026-11-23 returned zero recall matches for Friedrich; confirm tank age separately using the rating-plate serial pattern. See Serial Number Lookup.
What Are 5 Direct Alternatives to Friedrich PROH40 T2 FD350UM?
Homeowners cross-shopping Friedrich PROH40 T2 FD350UM frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Rheem CPROPH40 T2 RH350BM | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.5 (at parity) | 879 |
| Ruud PRO H40 T2 RU310BM | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.5 (at parity) | 879 |
| Richmond 10CE40-HP5U15 | Hybrid/Electric Heat Pump | 36 gal | 46 gal | 3.45 (-0.05) | 643 |
| A. O. Smith CAHP-40 2** | Hybrid/Electric Heat Pump | 36 gal | 55 gal | 3.6 (+0.10) | 902 |
| Rheem ECE H40 T2 RH310BM | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.5 (at parity) | 879 |
Which Home Setups Are NOT a Fit for Friedrich PROH40 T2 FD350UM?
Comparing Friedrich PROH40 T2 FD350UM against Rheem CPROPH40 T2 RH350BM requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.
Key Limitations & Exclusions
- Friedrich PROH40 T2 FD350UM needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Friedrich PROH40 T2 FD350UM directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Sizing, Efficiency & Recall Answers for Friedrich PROH40 T2 FD350UM
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does Friedrich PROH40 T2 FD350UM score under 10 CFR 430.32 May 2029 water heater minimums?
Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Friedrich PROH40 T2 FD350UM logs 3.5 UEF (Pass: +1.20 / +52.2%) within the 706-unit Hybrid/Electric Heat Pump group.
What physical clearance dimensions apply when installing Friedrich PROH40 T2 FD350UM?
With a 62.3 in. height and 20.3 in. diameter, Friedrich PROH40 T2 FD350UM fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" d), plus 6–12 in. above for plumbing shutoffs.
What 240V circuit or IFGC fuel line capacity fits Friedrich PROH40 T2 FD350UM?
Powered via 240V at 21A max, Friedrich PROH40 T2 FD350UM requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.
How do state electricity prices change annual costs for Friedrich PROH40 T2 FD350UM?
Annual electric spend for Friedrich PROH40 T2 FD350UM (879 kWh/yr) averages $160/yr nationwide (ranging from $129/yr in Washington hydro tiers up to $415/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.
What homeowner setups should avoid choosing Friedrich PROH40 T2 FD350UM?
Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Friedrich PROH40 T2 FD350UM.
Is Friedrich PROH40 T2 FD350UM sized adequately for a 2-to-4-person household?
ENERGY STAR certifies Friedrich PROH40 T2 FD350UM at 60 gal First Hour Rating (-12 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.
Does Friedrich have active CPSC SaferProducts notices affecting PROH40 T2 FD350UM?
Zero CPSC recall alerts matched Friedrich (2026-11-23 check). Keep your Friedrich PROH40 T2 FD350UM serial code handy to track standard 6-to-12-year OEM warranty coverage.
Which competing water heater matches Friedrich PROH40 T2 FD350UM (3.5 UEF) most closely?
State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Friedrich PROH40 T2 FD350UM. Closest peer in Hybrid/Electric Heat Pump is Rheem CPROPH40 T2 RH350BM (3.5 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)