Rheem ECE H50 T2 RH310BM Water Heater Specifications (3.5 UEF)

Certified at 3.5 UEF across its 45-gallon nominal tank, 67 gal First Hour Rating, Rheem ECE H50 T2 RH310BM (Hybrid/Electric Heat Pump, Electric) places #481 of 706 out of 706 ENERGY STAR models (PD 2408546). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.20 / +52.2%. Rated annual electricity draw of 915 kWh/yr equates to roughly $166/yr ($1,662 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH50 T2 FD310BM (3.5 UEF).

Uniform Energy Factor
3.5 UEF
Cohort UEF Rank
#481 of 706
First Hour Rating
67 gal
Storage Volume
45 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.20 / +52.2%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Rheem ECE H50 T2 RH310BM at 3.5 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Rheem ECE H50 T2 RH310BM: 3.50
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Rheem ECE H50 T2 RH310BM relative to the cohort median.
Efficiency comparison & rule summary

Tested at 3.5 UEF, Rheem ECE H50 T2 RH310BM places #481 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (-0.20 UEF vs. 3.70 UEF median).

Rheem ECE H50 T2 RH310BM clears 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.20 UEF (+52.2% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 915 kWh/yr for Rheem ECE H50 T2 RH310BM runs ~$166/yr vs. ~$632/yr for a 0.92 UEF electric tank.

State electric sensitivity for Rheem ECE H50 T2 RH310BM: 10-year operating spend spans $1,339 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,317 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to Rheem ECE H50 T2 RH310BM include Friedrich PROH50 T2 FD310BM (3.5 UEF, at parity) alongside Ruud PRO H50 T2 RU310BM (3.5 UEF, at parity).

Where Does Rheem ECE H50 T2 RH310BM Rank Against Peer Hybrid/Electric Heat Pump Units?

Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, Rheem ECE H50 T2 RH310BM holds #481 of 706; inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRheem236 certified listingsENERGY STAR PD 2408546
Model NumberECE H50 T2 RH310BMDraw pattern: Medium-UsageECE H50 T2 RH310BM
Uniform Energy Factor (UEF)3.5-0.20 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)67 gal-5 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use915 kWh/yr-157 kWh/yr vs. 1,072 kWh/yr medianEst. $166/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency400%-29.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)61.8" H x 22.3" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 21 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-10-15Certified 2026-10-15Markets: Canada

How Much Electricity Does ECE H50 T2 RH310BM Use in Different States?

Estimated at $166/yr nationally (915 kWh/yr), 10-year utility spending for Rheem ECE H50 T2 RH310BM shifts sharply between low-rate hydro and coastal grids.

Estimated Annual Electricity Cost by State Rate (915 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$166.00/yrHawaii$432.00/yrCalifornia$272.00/yrTexas$146.00/yrWashington$134.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $166/yr $1,662 $4,660
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $432/yr $4,317 $12,106
California 29.75 ¢/kWh ($0.2975) $272/yr $2,722 $7,634
Texas 15.91 ¢/kWh ($0.1591) $146/yr $1,456 $4,083
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $134/yr $1,339 $3,754
Estimated electricity spend (915 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Does CPSC Flag Any Safety Notices on Rheem Units?

Checking 2026-11-23 SaferProducts data shows 4 notices mentioning Rheem; always cross-reference affected serial prefixes before ordering components. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #16177 (2016-05-26): Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot (CPSC Notice)
  • Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
  • Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

Which Competing Hybrid/Electric Heat Pump Models Compare Closest to ECE H50 T2 RH310BM?

Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to Rheem ECE H50 T2 RH310BM's gallon capacity and 3.5 UEF efficiency.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH50 T2 FD310BM Hybrid/Electric Heat Pump 45 gal 67 gal 3.5 (at parity) 915
Ruud PRO H50 T2 RU310BM Hybrid/Electric Heat Pump 45 gal 67 gal 3.5 (at parity) 915
A. O. Smith HPACO-45 1**+AXST-50T 1** Hybrid/Electric Heat Pump 45 gal 67 gal 3.52 (+0.02) 923
American MHPCO-45 1**+MXST-50T 1** Hybrid/Electric Heat Pump 45 gal 67 gal 3.52 (+0.02) 923
Friedrich PROH50 T2 FD310UM Hybrid/Electric Heat Pump 45 gal 67 gal 3.5 (at parity) 915

Which Home Setups Are NOT a Fit for Rheem ECE H50 T2 RH310BM?

Comparing Rheem ECE H50 T2 RH310BM against Friedrich PROH50 T2 FD310BM requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • Rheem ECE H50 T2 RH310BM needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Rheem ECE H50 T2 RH310BM directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Rheem ECE H50 T2 RH310BM Strong Fit — 3.5 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH50 T2 FD310BM footprint.

Common Homeowner Questions for Rheem ECE H50 T2 RH310BM

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Rheem ECE H50 T2 RH310BM score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Rheem ECE H50 T2 RH310BM logs 3.5 UEF (Pass: +1.20 / +52.2%) within the 706-unit Hybrid/Electric Heat Pump group.

What physical clearance dimensions apply when installing Rheem ECE H50 T2 RH310BM?

With a 61.8 in. height and 22.3 in. diameter, Rheem ECE H50 T2 RH310BM fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" d), plus 6–12 in. above for plumbing shutoffs.

What 240V circuit or IFGC fuel line capacity fits Rheem ECE H50 T2 RH310BM?

Powered via 240V at 21A max, Rheem ECE H50 T2 RH310BM requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

How do state electricity prices change annual costs for Rheem ECE H50 T2 RH310BM?

Annual electric spend for Rheem ECE H50 T2 RH310BM (915 kWh/yr) averages $166/yr nationwide (ranging from $134/yr in Washington hydro tiers up to $432/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

What homeowner setups should avoid choosing Rheem ECE H50 T2 RH310BM?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Rheem ECE H50 T2 RH310BM.

Is Rheem ECE H50 T2 RH310BM sized adequately for a 2-to-4-person household?

ENERGY STAR certifies Rheem ECE H50 T2 RH310BM at 67 gal First Hour Rating (-5 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

Does Rheem have active CPSC SaferProducts notices affecting ECE H50 T2 RH310BM?

CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Which competing water heater matches Rheem ECE H50 T2 RH310BM (3.5 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Rheem ECE H50 T2 RH310BM. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH50 T2 FD310BM (3.5 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks