Rheem CPROPH50 T2 RH400-30 Water Heater Specifications (3.88 UEF)
With PD 3554203 certification, Rheem CPROPH50 T2 RH400-30 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.88 UEF rating across its 45-gallon nominal tank, 67 gal First Hour Rating, standing #165 of 706 across 706 peers with Pass: +1.58 / +68.7% for May 6, 2029. Rated annual electricity draw of 846 kWh/yr equates to roughly $154/yr ($1,536 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH50 T2 FD400-30 (3.88 UEF).
- Uniform Energy Factor
- 3.88 UEF
- Cohort UEF Rank
- #165 of 706 (top 30.6%)
- First Hour Rating
- 67 gal
- Storage Volume
- 45 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.58 / +68.7%

ENERGY STAR certification places Rheem CPROPH50 T2 RH400-30 at 3.88 UEF (#165 of 706; +0.18 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.
May 6, 2029 readiness: Rheem CPROPH50 T2 RH400-30 stands +1.58 UEF (+68.7%) relative to 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 846 kWh/yr for Rheem CPROPH50 T2 RH400-30 runs ~$154/yr vs. ~$648/yr for a 0.92 UEF electric tank.
State electric sensitivity for Rheem CPROPH50 T2 RH400-30: 10-year operating spend spans $1,238 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,991 in Hawaii (Highest EIA State) (47.18 cents/kWh).
In the Hybrid/Electric Heat Pump tier, Friedrich PROH50 T2 FD400-30 (3.88 UEF, at parity) and Richmond 10CE50-HP5S30 (3.88 UEF, at parity) bracket Rheem CPROPH50 T2 RH400-30.
What Physical and Thermal Ratings Define Rheem CPROPH50 T2 RH400-30?
Positioning at #165 of 706 (top 30.6%) out of 706 Hybrid/Electric Heat Pump peers, Rheem CPROPH50 T2 RH400-30 pairs measured UEF performance with specific clearance and wiring rules.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Rheem | 236 certified listings | ENERGY STAR PD 3554203 |
| Model Number | CPROPH50 T2 RH400-30 | Draw pattern: Medium-Usage | CPROPH50 T2 RH400-30 |
| Uniform Energy Factor (UEF) | 3.88 | +0.18 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 67 gal | -5 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 846 kWh/yr | -226 kWh/yr vs. 1,072 kWh/yr median | Est. $154/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 430% | +1.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 61.8" H x 22.3" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: Canada |
Why Do State Utility Rates Shift CPROPH50 T2 RH400-30 Running Costs?
Consuming 846 kWh annually puts Rheem CPROPH50 T2 RH400-30 near $154/yr at US baseline tariffs, with multi-state EIA comparisons charted below.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $154/yr | $1,536 | $4,943 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $399/yr | $3,991 | $12,842 |
| California | 29.75 ¢/kWh ($0.2975) | $252/yr | $2,517 | $8,098 |
| Texas | 15.91 ¢/kWh ($0.1591) | $135/yr | $1,346 | $4,331 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $124/yr | $1,238 | $3,982 |
Have Any Rheem Series Triggered CPSC Recalls?
SaferProducts records retrieved 2026-11-23 list 4 brand notices under Rheem; inspect model coverage dates prior to valve or anode service. See Serial Number Lookup.
- Recall #16177 (2016-05-26): Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot (CPSC Notice)
- Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
- Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
What Are 5 Direct Alternatives to Rheem CPROPH50 T2 RH400-30?
Homeowners cross-shopping Rheem CPROPH50 T2 RH400-30 frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Friedrich PROH50 T2 FD400-30 | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (at parity) | 846 |
| Richmond 10CE50-HP5S30 | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (at parity) | 846 |
| Ruud CPROPH50 T2 CD375-30 | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (at parity) | 846 |
| Bradford White RE2HP50**-1NCTT | Hybrid/Electric Heat Pump | 45 gal | 65 gal | 3.89 (+0.01) | 835 |
| Friedrich PROH50 T2 FD400-SO | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (at parity) | 846 |
What Are the Limitations of Rheem CPROPH50 T2 RH400-30 and Who Should Not Install It?
Before ordering Rheem CPROPH50 T2 RH400-30 (Hybrid/Electric Heat Pump, 3.88 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.
Key Limitations & Exclusions
- Rheem CPROPH50 T2 RH400-30 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Rheem CPROPH50 T2 RH400-30 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Sizing, Efficiency & Recall Answers for Rheem CPROPH50 T2 RH400-30
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Does Rheem CPROPH50 T2 RH400-30 pass the May 6, 2029 federal DOE efficiency rule?
Rheem CPROPH50 T2 RH400-30 carries a verified 3.88 UEF rating (Pass: +1.58 / +68.7%), ranking #165 of 706 (top 30.6%) across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.
What doorway width and ceiling height does Rheem CPROPH50 T2 RH400-30 need?
Rheem CPROPH50 T2 RH400-30 stands 61.8 in. high with a 22.3 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.
What gas pipe size or electrical breaker does Rheem CPROPH50 T2 RH400-30 require?
Rheem CPROPH50 T2 RH400-30 uses a 240V branch circuit at 21A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.
How much electricity or energy does Rheem CPROPH50 T2 RH400-30 cost per year to run?
Rated at 846 kWh/yr, Rheem CPROPH50 T2 RH400-30 costs about $154/yr ($1,540 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $124/yr in Washington hydro tiers up to $399/yr in Hawaii).
Who should NOT install Rheem CPROPH50 T2 RH400-30, and what are its limits?
Rheem CPROPH50 T2 RH400-30 (3.88 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.
How many bathrooms or people can Rheem CPROPH50 T2 RH400-30 serve at peak demand?
Rheem CPROPH50 T2 RH400-30 achieves a 67 gal First Hour Rating (-5 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.
Are there CPSC safety recalls or serial checks for Rheem CPROPH50 T2 RH400-30?
CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
What 2026 rebates apply to Rheem CPROPH50 T2 RH400-30, and what peer compares closest?
Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH50 T2 FD400-30 (3.88 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)