GE Profile PF80S10FPY01 Water Heater Specifications (3.5 UEF)
Certified at 3.5 UEF across its 80-gallon nominal tank, 94 gal First Hour Rating, GE Profile PF80S10FPY01 (Hybrid/Electric Heat Pump, Electric) places #481 of 706 out of 706 ENERGY STAR models (PD 4480876). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.00 / +40.0%. Rated annual electricity draw of 1,417 kWh/yr equates to roughly $257/yr ($2,573 over 10 years) at 18.16 cents/kWh. Closest certified alternative is VAUGHN THERMAL MP80FHPT (3.5 UEF).
- Uniform Energy Factor
- 3.5 UEF
- Cohort UEF Rank
- #481 of 706
- First Hour Rating
- 94 gal
- Storage Volume
- 80 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.00 / +40.0%

Tested at 3.5 UEF, GE Profile PF80S10FPY01 places #481 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (-0.20 UEF vs. 3.70 UEF median).
GE Profile PF80S10FPY01 clears 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.00 UEF (+40.0% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 1,417 kWh/yr for GE Profile PF80S10FPY01 runs ~$257/yr vs. ~$979/yr for a 0.92 UEF electric tank. Acoustic output is 41 dBA (quieter than 81.2% of Hybrid/Electric Heat Pump models).
State electric sensitivity for GE Profile PF80S10FPY01: 10-year operating spend spans $2,073 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,685 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Closest alternatives to GE Profile PF80S10FPY01 include VAUGHN THERMAL MP80FHPT (3.5 UEF, at parity) alongside Reclaim Energy MP80F-RC (3.8 UEF, delta +0.30).
Where Does GE Profile PF80S10FPY01 Rank Against Peer Hybrid/Electric Heat Pump Units?
Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, GE Profile PF80S10FPY01 holds #481 of 706; inspect footprint, circuit load, and efficiency deltas here.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | GE Profile | 18 certified listings | ENERGY STAR PD 4480876 |
| Model Number | PF80S10FPY01 | Draw pattern: High-Usage | PF80S10FPY01 |
| Uniform Energy Factor (UEF) | 3.5 | -0.20 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 94 gal | +22 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,417 kWh/yr | +345 kWh/yr vs. 1,072 kWh/yr median | Est. $257/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 402% | -27.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 57.2" H x 21.5" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.5" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 120 V / 7.5 A max | 120V plug-in retrofit circuit; slower heat-pump-only recovery | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R1234YF | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Sound Pressure Level | 41 dBA | top 18.8% · quieter than 81.2% of Hybrid/Electric Heat Pump models · -8 dBA vs. 49 dBA median | Indoor placement check |
| Certification Date | 2025-07-30 | Certified 2025-07-30 | Markets: United States |
How Much Electricity Does PF80S10FPY01 Use in Different States?
Estimated at $257/yr nationally (1,417 kWh/yr), 10-year utility spending for GE Profile PF80S10FPY01 shifts sharply between low-rate hydro and coastal grids.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $257/yr | $2,573 | $7,217 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $669/yr | $6,685 | $18,749 |
| California | 29.75 ¢/kWh ($0.2975) | $422/yr | $4,216 | $11,823 |
| Texas | 15.91 ¢/kWh ($0.1591) | $225/yr | $2,254 | $6,323 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $207/yr | $2,073 | $5,814 |
Does CPSC Flag Any Safety Notices on GE Profile Units?
No open CPSC recall alerts appeared for GE Profile as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See Serial Number Lookup.
Which Competing Hybrid/Electric Heat Pump Models Compare Closest to PF80S10FPY01?
Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to GE Profile PF80S10FPY01's gallon capacity and 3.5 UEF efficiency.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| VAUGHN THERMAL MP80FHPT | Hybrid/Electric Heat Pump | 80 gal | 86 gal | 3.5 (at parity) | 1,375 |
| Reclaim Energy MP80F-RC | Hybrid/Electric Heat Pump | 80 gal | 98 gal | 3.8 (+0.30) | 1,273 |
| Smart Solar SSG2-ES 80 | Hybrid/Electric Heat Pump | 80 gal | 55 gal | 2.71 (-0.79) | 1,192 |
| A. O. Smith CAHP-80 2** | Hybrid/Electric Heat Pump | 81 gal | 95 gal | 3.88 (+0.38) | 1,279 |
| VAUGHN THERMAL MP80F-RC | Hybrid/Electric Heat Pump | 80 gal | 98 gal | 3.8 (+0.30) | 1,273 |
What Installation Caveats Apply Before Buying GE Profile PF80S10FPY01?
Even high-UEF units like GE Profile PF80S10FPY01 (3.5 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.
Key Limitations & Exclusions
- GE Profile PF80S10FPY01 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 41 dBA; avoid mounting GE Profile PF80S10FPY01 directly beside quiet bedrooms.
- Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Common Homeowner Questions for GE Profile PF80S10FPY01
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Is GE Profile PF80S10FPY01 eligible for continued manufacture past May 6, 2029?
At 3.5 UEF, GE Profile PF80S10FPY01 achieves Pass: +1.00 / +40.0% for the 2029 DOE standard and stands #481 of 706 against VAUGHN THERMAL MP80FHPT and Reclaim Energy MP80F-RC.
How tall and wide is GE Profile PF80S10FPY01, and what service clearance is needed?
Physical dimensions for GE Profile PF80S10FPY01 are 57.2 in. height and 21.5 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.5" d)); verify stair turns and drain pan width before delivery.
Will GE Profile PF80S10FPY01 require upgrading household electrical panels or gas piping?
GE Profile PF80S10FPY01 draws 120V at 7.5A max (120V plug-in retrofit circuit; slower heat-pump-only recovery); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.
Is GE Profile PF80S10FPY01 economical to operate at 18.16 cents/kWh US electric rates?
Expect roughly $257/yr ($2,570 over 10 years) to power GE Profile PF80S10FPY01 at 1,417 kWh/yr under the 18.16 cents/kWh US average (ranging from $207/yr in Washington hydro tiers up to $669/yr in Hawaii).
Which installation bottlenecks limit GE Profile PF80S10FPY01?
If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, GE Profile PF80S10FPY01 drops into resistance mode more often.
How does GE Profile PF80S10FPY01 handle simultaneous showers and laundry?
Delivering 94 gal in the first hour (+22 gal vs. 72 gal median), GE Profile PF80S10FPY01 combines 80 gal tank storage with rapid burner/element recovery.
How long is the warranty on GE Profile PF80S10FPY01 and how do you decode its serial?
CPSC records show 0 active plumbing recalls for GE Profile as of 2026-11-23. Confirm install proof and serial manufacture year on GE Profile PF80S10FPY01 before calling service.
How do 2026 post-OBBBA rebates affect buying GE Profile PF80S10FPY01?
Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is VAUGHN THERMAL MP80FHPT (3.5 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)