Skip to main content
ENERGY STAR water heater model · PD 4623615

Reclaim Energy MP80F-RC Water Heater Specifications (3.8 UEF)

The Reclaim Energy MP80F-RC (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.8 UEF rating across its 80-gallon nominal tank, 98 gal First Hour Rating, ranking #268 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 4623615). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.30 / +52.0%. Rated annual electricity draw of 1,273 kWh/yr equates to roughly $231/yr ($2,312 over 10 years) at 18.16 cents/kWh. Closest certified alternative is VAUGHN THERMAL MP80F-RC (3.8 UEF).

Uniform Energy Factor
3.8 UEF
Cohort UEF Rank
#268 of 706 (top 41.9%)
First Hour Rating
98 gal
Storage Volume
80 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.30 / +52.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Reclaim Energy MP80F-RC at 3.8 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Reclaim Energy MP80F-RC: 3.80
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Reclaim Energy MP80F-RC relative to the cohort median.
Efficiency comparison & rule summary

Reclaim Energy MP80F-RC (3.8 UEF) ranks #268 of 706 Hybrid/Electric Heat Pump models — 29-way tie; top 41.9%, more efficient than 58.1% of Hybrid/Electric Heat Pump models, +0.10 UEF above the 3.70 UEF median.

Federal 2029 margin for Reclaim Energy MP80F-RC: +1.30 UEF (+52.0%) vs. 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,273 kWh/yr for Reclaim Energy MP80F-RC runs ~$231/yr vs. ~$955/yr for a 0.92 UEF electric tank. Acoustic output is 37 dBA (quieter than 93.3% of Hybrid/Electric Heat Pump models).

State electric sensitivity for Reclaim Energy MP80F-RC: 10-year operating spend spans $1,862 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,006 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: Reclaim Energy MP80F-RC (3.8 UEF) compares closely with VAUGHN THERMAL MP80F-RC (3.8 UEF, at parity) and GE Profile PF80S10FPY01 (3.5 UEF, delta -0.30).

How Do Reclaim Energy MP80F-RC Specs Compare to Hybrid/Electric Heat Pump Medians?

Reclaim Energy MP80F-RC places #268 of 706 (top 41.9%) across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandReclaim Energy2 certified listingsENERGY STAR PD 4623615
Model NumberMP80F-RCDraw pattern: High-UsageMP80F-RC
Uniform Energy Factor (UEF)3.8+0.10 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)98 gal+26 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,273 kWh/yr+201 kWh/yr vs. 1,072 kWh/yr medianEst. $231/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency435%+6.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)53" H x 30" DFits standard 72 in. basement/garage clearance; tight at 28 in. door (30" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 6 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-744 (CO₂) (GWP:1 | Lower GWP)Lower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Sound Pressure Level37 dBAtop 6.7% · quieter than 93.3% of Hybrid/Electric Heat Pump models · -12 dBA vs. 49 dBA medianIndoor placement check
Certification Date2026-06-08Certified 2026-06-08Markets: United States, Canada

What Does MP80F-RC Cost to Operate Across State Electricity Rates?

At 1,273 kWh/yr, Reclaim Energy MP80F-RC runs roughly $231/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Estimated Annual Electricity Cost by State Rate (1,273 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$231.00/yrHawaii$601.00/yrCalifornia$379.00/yrTexas$203.00/yrWashington$186.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $231/yr $2,312 $7,237
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $601/yr $6,006 $18,801
California 29.75 ¢/kWh ($0.2975) $379/yr $3,787 $11,855
Texas 15.91 ¢/kWh ($0.1591) $203/yr $2,025 $6,340
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $186/yr $1,862 $5,830
Estimated electricity spend (1,273 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for Reclaim Energy Water Heaters?

Zero active CPSC recalls matched Reclaim Energy in our 2026-11-23 SaferProducts sweep; verify your individual tank date code via our lookup tool. See Serial Number Lookup.

Which Certified Water Heaters Match MP80F-RC Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to Reclaim Energy MP80F-RC by storage capacity and 3.8 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
VAUGHN THERMAL MP80F-RC Hybrid/Electric Heat Pump 80 gal 98 gal 3.8 (at parity) 1,273
GE Profile PF80S10FPY01 Hybrid/Electric Heat Pump 80 gal 94 gal 3.5 (-0.30) 1,417
Smart Solar SSG2-ES 80 Hybrid/Electric Heat Pump 80 gal 55 gal 2.71 (-1.09) 1,192
A. O. Smith CAHP-80 2** Hybrid/Electric Heat Pump 81 gal 95 gal 3.88 (+0.08) 1,279
GE Profile PJ80S10FPY01 Hybrid/Electric Heat Pump 80 gal 94 gal 3.5 (-0.30) 1,417

Who Is Reclaim Energy MP80F-RC Best For — and When Should You Pick VAUGHN THERMAL MP80F-RC?

Evaluate whether Reclaim Energy MP80F-RC's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

Key Limitations & Exclusions

  • Reclaim Energy MP80F-RC needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 37 dBA; avoid mounting Reclaim Energy MP80F-RC directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Reclaim Energy MP80F-RC Strong Fit — 3.8 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare VAUGHN THERMAL MP80F-RC footprint.

What Are the Key Questions About Reclaim Energy MP80F-RC?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Reclaim Energy MP80F-RC (3.8 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Reclaim Energy MP80F-RC records 3.8 UEF (Pass: +1.30 / +52.0%), placing #268 of 706 (top 41.9%) out of 706 certified Hybrid/Electric Heat Pump configurations.

Does Reclaim Energy MP80F-RC fit inside a tight hallway closet or low-headroom utility room?

Reclaim Energy MP80F-RC requires room for its 53 in. vertical shell and 30 in. diameter (fits standard 72 in. basement/garage clearance; tight at 28 in. door (30" d)), plus service access for annual sediment draining.

What power supply or fuel line specs govern Reclaim Energy MP80F-RC?

For Reclaim Energy MP80F-RC, plan a 240V circuit at 6A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.

What annual utility bill should homeowners budget for Reclaim Energy MP80F-RC?

Using 1,273 kWh/yr, Reclaim Energy MP80F-RC generates an estimated $231/yr electric bill at 18.16 cents/kWh (ranging from $186/yr in Washington hydro tiers up to $601/yr in Hawaii)—use the custom rate slider above for your utility tariff.

What are the main drawbacks of Reclaim Energy MP80F-RC (3.8 UEF)?

Reclaim Energy MP80F-RC requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or VAUGHN THERMAL MP80F-RC.

What hot-water delivery rating governs Reclaim Energy MP80F-RC?

Rated for 98 gal FHR (+26 gal vs. 72 gal median), Reclaim Energy MP80F-RC prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

Where do homeowners screen Reclaim Energy MP80F-RC for recalls and tank age?

Verified clean against 2026-11-23 CPSC recall feeds for Reclaim Energy; use our browser-only serial decoder to inspect Reclaim Energy MP80F-RC's age and warranty window.

What alternative models sit closest to Reclaim Energy MP80F-RC in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is VAUGHN THERMAL MP80F-RC (3.8 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks