Skip to main content
ENERGY STAR water heater model · PD 4518064

VAUGHN THERMAL MP80FHPT Water Heater Specifications (3.5 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, VAUGHN THERMAL MP80FHPT (Electric) achieves a certified 3.5 UEF rating across its 80-gallon nominal tank, 86 gal First Hour Rating (rank #481 of 706, PD 4518064) and verifies as Pass: +1.00 / +40.0% for 2029 DOE floors. Rated annual electricity draw of 1,375 kWh/yr equates to roughly $250/yr ($2,497 over 10 years) at 18.16 cents/kWh. Closest certified alternative is GE Profile PF80S10FPY01 (3.5 UEF).

Uniform Energy Factor
3.5 UEF
Cohort UEF Rank
#481 of 706
First Hour Rating
86 gal
Storage Volume
80 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.00 / +40.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking VAUGHN THERMAL MP80FHPT at 3.5 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50VAUGHN THERMAL MP80FHPT: 3.50
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows VAUGHN THERMAL MP80FHPT relative to the cohort median.
Efficiency comparison & rule summary

VAUGHN THERMAL MP80FHPT records 3.5 UEF efficiency, putting it #481 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: VAUGHN THERMAL MP80FHPT exceeds 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.00 UEF (+40.0%). At EIA August 2026 national rates (18.16 cents/kWh), 1,375 kWh/yr for VAUGHN THERMAL MP80FHPT runs ~$250/yr vs. ~$950/yr for a 0.92 UEF electric tank.

State electric sensitivity for VAUGHN THERMAL MP80FHPT: 10-year operating spend spans $2,012 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,487 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside VAUGHN THERMAL MP80FHPT (3.5 UEF) are GE Profile PF80S10FPY01 (3.5 UEF, at parity) and Reclaim Energy MP80F-RC (3.8 UEF, delta +0.30).

What Physical and Thermal Ratings Define VAUGHN THERMAL MP80FHPT?

Positioning at #481 of 706 out of 706 Hybrid/Electric Heat Pump peers, VAUGHN THERMAL MP80FHPT pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandVAUGHN THERMAL13 certified listingsENERGY STAR PD 4518064
Model NumberMP80FHPTDraw pattern: High-UsageMP80FHPT
Uniform Energy Factor (UEF)3.5-0.20 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)86 gal+14 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,375 kWh/yr+303 kWh/yr vs. 1,072 kWh/yr medianEst. $250/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency376%-53.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)66.5" H x 30" DVerify 72 in. vertical headroom; tight at 28 in. door (30" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 23 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Sound Pressure Level54 dBA+5 dBA vs. 49 dBA medianIndoor placement check
Certification Date2025-12-12Certified 2025-12-12Markets: United States, Canada

Why Do State Utility Rates Shift MP80FHPT Running Costs?

Consuming 1,375 kWh annually puts VAUGHN THERMAL MP80FHPT near $250/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Estimated Annual Electricity Cost by State Rate (1,375 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$250.00/yrHawaii$649.00/yrCalifornia$409.00/yrTexas$219.00/yrWashington$201.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $250/yr $2,497 $7,002
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $649/yr $6,487 $18,193
California 29.75 ¢/kWh ($0.2975) $409/yr $4,091 $11,472
Texas 15.91 ¢/kWh ($0.1591) $219/yr $2,188 $6,135
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $201/yr $2,012 $5,641
Estimated electricity spend (1,375 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any VAUGHN THERMAL Series Triggered CPSC Recalls?

SaferProducts screening on 2026-11-23 returned zero recall matches for VAUGHN THERMAL; confirm tank age separately using the rating-plate serial pattern. See Serial Number Lookup.

What Are 5 Direct Alternatives to VAUGHN THERMAL MP80FHPT?

Homeowners cross-shopping VAUGHN THERMAL MP80FHPT frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
GE Profile PF80S10FPY01 Hybrid/Electric Heat Pump 80 gal 94 gal 3.5 (at parity) 1,417
Reclaim Energy MP80F-RC Hybrid/Electric Heat Pump 80 gal 98 gal 3.8 (+0.30) 1,273
Smart Solar SSG2-ES 80 Hybrid/Electric Heat Pump 80 gal 55 gal 2.71 (-0.79) 1,192
A. O. Smith CAHP-80 2** Hybrid/Electric Heat Pump 81 gal 95 gal 3.88 (+0.38) 1,279
GE Profile PJ80S10FPY01 Hybrid/Electric Heat Pump 80 gal 94 gal 3.5 (at parity) 1,417

What Are the Limitations of VAUGHN THERMAL MP80FHPT and Who Should Not Install It?

Before ordering VAUGHN THERMAL MP80FHPT (Hybrid/Electric Heat Pump, 3.5 UEF), weigh space clearances, fuel piping, noise (54 dBA), and 2029 rule readiness across three scenarios.

Key Limitations & Exclusions

  • VAUGHN THERMAL MP80FHPT needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 54 dBA; avoid mounting VAUGHN THERMAL MP80FHPT directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing VAUGHN THERMAL MP80FHPT Strong Fit — 3.5 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare GE Profile PF80S10FPY01 footprint.

Sizing, Efficiency & Recall Answers for VAUGHN THERMAL MP80FHPT

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does VAUGHN THERMAL MP80FHPT pass the May 6, 2029 federal DOE efficiency rule?

VAUGHN THERMAL MP80FHPT carries a verified 3.5 UEF rating (Pass: +1.00 / +40.0%), ranking #481 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

What doorway width and ceiling height does VAUGHN THERMAL MP80FHPT need?

VAUGHN THERMAL MP80FHPT stands 66.5 in. high with a 30 in. diameter; verify 72 in. vertical headroom; tight at 28 in. door (30" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

What gas pipe size or electrical breaker does VAUGHN THERMAL MP80FHPT require?

VAUGHN THERMAL MP80FHPT uses a 240V branch circuit at 23A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

How much electricity or energy does VAUGHN THERMAL MP80FHPT cost per year to run?

Rated at 1,375 kWh/yr, VAUGHN THERMAL MP80FHPT costs about $250/yr ($2,500 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $201/yr in Washington hydro tiers up to $649/yr in Hawaii).

Who should NOT install VAUGHN THERMAL MP80FHPT, and what are its limits?

VAUGHN THERMAL MP80FHPT (3.5 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 54 dBA.

How many bathrooms or people can VAUGHN THERMAL MP80FHPT serve at peak demand?

VAUGHN THERMAL MP80FHPT achieves a 86 gal First Hour Rating (+14 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

Are there CPSC safety recalls or serial checks for VAUGHN THERMAL MP80FHPT?

No active CPSC recalls matched VAUGHN THERMAL as of 2026-11-23. Always decode the serial tag on VAUGHN THERMAL MP80FHPT because OEM tank/exchanger warranties span 6–12 years.

What 2026 rebates apply to VAUGHN THERMAL MP80FHPT, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is GE Profile PF80S10FPY01 (3.5 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)