VAUGHN THERMAL MP80FHPT Water Heater Specifications (3.5 UEF)
In the 706-unit Hybrid/Electric Heat Pump class, VAUGHN THERMAL MP80FHPT (Electric) achieves a certified 3.5 UEF rating across its 80-gallon nominal tank, 86 gal First Hour Rating (rank #481 of 706, PD 4518064) and verifies as Pass: +1.00 / +40.0% for 2029 DOE floors. Rated annual electricity draw of 1,375 kWh/yr equates to roughly $250/yr ($2,497 over 10 years) at 18.16 cents/kWh. Closest certified alternative is GE Profile PF80S10FPY01 (3.5 UEF).
- Uniform Energy Factor
- 3.5 UEF
- Cohort UEF Rank
- #481 of 706
- First Hour Rating
- 86 gal
- Storage Volume
- 80 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.00 / +40.0%

VAUGHN THERMAL MP80FHPT records 3.5 UEF efficiency, putting it #481 of 706 among 706 Hybrid/Electric Heat Pump peers.
10 CFR 430.32(d)(2) compliance: VAUGHN THERMAL MP80FHPT exceeds 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.00 UEF (+40.0%). At EIA August 2026 national rates (18.16 cents/kWh), 1,375 kWh/yr for VAUGHN THERMAL MP80FHPT runs ~$250/yr vs. ~$950/yr for a 0.92 UEF electric tank.
State electric sensitivity for VAUGHN THERMAL MP80FHPT: 10-year operating spend spans $2,012 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,487 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Competing options beside VAUGHN THERMAL MP80FHPT (3.5 UEF) are GE Profile PF80S10FPY01 (3.5 UEF, at parity) and Reclaim Energy MP80F-RC (3.8 UEF, delta +0.30).
What Physical and Thermal Ratings Define VAUGHN THERMAL MP80FHPT?
Positioning at #481 of 706 out of 706 Hybrid/Electric Heat Pump peers, VAUGHN THERMAL MP80FHPT pairs measured UEF performance with specific clearance and wiring rules.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | VAUGHN THERMAL | 13 certified listings | ENERGY STAR PD 4518064 |
| Model Number | MP80FHPT | Draw pattern: High-Usage | MP80FHPT |
| Uniform Energy Factor (UEF) | 3.5 | -0.20 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 86 gal | +14 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,375 kWh/yr | +303 kWh/yr vs. 1,072 kWh/yr median | Est. $250/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 376% | -53.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 66.5" H x 30" D | Verify 72 in. vertical headroom; tight at 28 in. door (30" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 23 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Sound Pressure Level | 54 dBA | +5 dBA vs. 49 dBA median | Indoor placement check |
| Certification Date | 2025-12-12 | Certified 2025-12-12 | Markets: United States, Canada |
Why Do State Utility Rates Shift MP80FHPT Running Costs?
Consuming 1,375 kWh annually puts VAUGHN THERMAL MP80FHPT near $250/yr at US baseline tariffs, with multi-state EIA comparisons charted below.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $250/yr | $2,497 | $7,002 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $649/yr | $6,487 | $18,193 |
| California | 29.75 ¢/kWh ($0.2975) | $409/yr | $4,091 | $11,472 |
| Texas | 15.91 ¢/kWh ($0.1591) | $219/yr | $2,188 | $6,135 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $201/yr | $2,012 | $5,641 |
Have Any VAUGHN THERMAL Series Triggered CPSC Recalls?
SaferProducts screening on 2026-11-23 returned zero recall matches for VAUGHN THERMAL; confirm tank age separately using the rating-plate serial pattern. See Serial Number Lookup.
What Are 5 Direct Alternatives to VAUGHN THERMAL MP80FHPT?
Homeowners cross-shopping VAUGHN THERMAL MP80FHPT frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| GE Profile PF80S10FPY01 | Hybrid/Electric Heat Pump | 80 gal | 94 gal | 3.5 (at parity) | 1,417 |
| Reclaim Energy MP80F-RC | Hybrid/Electric Heat Pump | 80 gal | 98 gal | 3.8 (+0.30) | 1,273 |
| Smart Solar SSG2-ES 80 | Hybrid/Electric Heat Pump | 80 gal | 55 gal | 2.71 (-0.79) | 1,192 |
| A. O. Smith CAHP-80 2** | Hybrid/Electric Heat Pump | 81 gal | 95 gal | 3.88 (+0.38) | 1,279 |
| GE Profile PJ80S10FPY01 | Hybrid/Electric Heat Pump | 80 gal | 94 gal | 3.5 (at parity) | 1,417 |
What Are the Limitations of VAUGHN THERMAL MP80FHPT and Who Should Not Install It?
Before ordering VAUGHN THERMAL MP80FHPT (Hybrid/Electric Heat Pump, 3.5 UEF), weigh space clearances, fuel piping, noise (54 dBA), and 2029 rule readiness across three scenarios.
Key Limitations & Exclusions
- VAUGHN THERMAL MP80FHPT needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 54 dBA; avoid mounting VAUGHN THERMAL MP80FHPT directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Sizing, Efficiency & Recall Answers for VAUGHN THERMAL MP80FHPT
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Does VAUGHN THERMAL MP80FHPT pass the May 6, 2029 federal DOE efficiency rule?
VAUGHN THERMAL MP80FHPT carries a verified 3.5 UEF rating (Pass: +1.00 / +40.0%), ranking #481 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.
What doorway width and ceiling height does VAUGHN THERMAL MP80FHPT need?
VAUGHN THERMAL MP80FHPT stands 66.5 in. high with a 30 in. diameter; verify 72 in. vertical headroom; tight at 28 in. door (30" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.
What gas pipe size or electrical breaker does VAUGHN THERMAL MP80FHPT require?
VAUGHN THERMAL MP80FHPT uses a 240V branch circuit at 23A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.
How much electricity or energy does VAUGHN THERMAL MP80FHPT cost per year to run?
Rated at 1,375 kWh/yr, VAUGHN THERMAL MP80FHPT costs about $250/yr ($2,500 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $201/yr in Washington hydro tiers up to $649/yr in Hawaii).
Who should NOT install VAUGHN THERMAL MP80FHPT, and what are its limits?
VAUGHN THERMAL MP80FHPT (3.5 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 54 dBA.
How many bathrooms or people can VAUGHN THERMAL MP80FHPT serve at peak demand?
VAUGHN THERMAL MP80FHPT achieves a 86 gal First Hour Rating (+14 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.
Are there CPSC safety recalls or serial checks for VAUGHN THERMAL MP80FHPT?
No active CPSC recalls matched VAUGHN THERMAL as of 2026-11-23. Always decode the serial tag on VAUGHN THERMAL MP80FHPT because OEM tank/exchanger warranties span 6–12 years.
What 2026 rebates apply to VAUGHN THERMAL MP80FHPT, and what peer compares closest?
Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is GE Profile PF80S10FPY01 (3.5 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)