GE Profile PH80S10BNY01 Water Heater Specifications (4.5 UEF)
With PD 4480878 certification, GE Profile PH80S10BNY01 (Hybrid/Electric Heat Pump, Electric) achieves a certified 4.5 UEF rating across its 80-gallon nominal tank, 101 gal First Hour Rating, standing #1 of 706 across 706 peers with Pass: +2.00 / +80.0% for May 6, 2029. Rated annual electricity draw of 1,102 kWh/yr equates to roughly $200/yr ($2,001 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Reclaim Energy MP80F-RC (3.8 UEF).
- Uniform Energy Factor
- 4.5 UEF
- Cohort UEF Rank
- #1 of 706 (top 0.4%)
- First Hour Rating
- 101 gal
- Storage Volume
- 80 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +2.00 / +80.0%

ENERGY STAR certification places GE Profile PH80S10BNY01 at 4.5 UEF (#1 of 706; +0.80 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.
May 6, 2029 readiness: GE Profile PH80S10BNY01 stands +2.00 UEF (+80.0%) relative to 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,102 kWh/yr for GE Profile PH80S10BNY01 runs ~$200/yr vs. ~$979/yr for a 0.92 UEF electric tank. Acoustic output is 41 dBA (quieter than 81.2% of Hybrid/Electric Heat Pump models).
State electric sensitivity for GE Profile PH80S10BNY01: 10-year operating spend spans $1,612 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,199 in Hawaii (Highest EIA State) (47.18 cents/kWh).
In the Hybrid/Electric Heat Pump tier, Reclaim Energy MP80F-RC (3.8 UEF, delta -0.70) and VAUGHN THERMAL MP80F-RC (3.8 UEF, delta -0.70) bracket GE Profile PH80S10BNY01.
What Physical and Thermal Ratings Define GE Profile PH80S10BNY01?
Positioning at #1 of 706 (top 0.4%) out of 706 Hybrid/Electric Heat Pump peers, GE Profile PH80S10BNY01 pairs measured UEF performance with specific clearance and wiring rules.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | GE Profile | 18 certified listings | ENERGY STAR PD 4480878 |
| Model Number | PH80S10BNY01 | Draw pattern: High-Usage | PH80S10BNY01 |
| Uniform Energy Factor (UEF) | 4.5 | +0.80 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 101 gal | +29 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,102 kWh/yr | +30 kWh/yr vs. 1,072 kWh/yr median | Est. $200/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 494% | +65.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 57.2" H x 21.5" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.5" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 23 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R1234YF | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Sound Pressure Level | 41 dBA | top 18.8% · quieter than 81.2% of Hybrid/Electric Heat Pump models · -8 dBA vs. 49 dBA median | Indoor placement check |
| Certification Date | 2025-07-30 | Certified 2025-07-30 | Markets: United States |
Why Do State Utility Rates Shift PH80S10BNY01 Running Costs?
Consuming 1,102 kWh annually puts GE Profile PH80S10BNY01 near $200/yr at US baseline tariffs, with multi-state EIA comparisons charted below.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $200/yr | $2,001 | $7,787 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $520/yr | $5,199 | $20,231 |
| California | 29.75 ¢/kWh ($0.2975) | $328/yr | $3,278 | $12,757 |
| Texas | 15.91 ¢/kWh ($0.1591) | $175/yr | $1,753 | $6,822 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $161/yr | $1,612 | $6,273 |
Have Any GE Profile Series Triggered CPSC Recalls?
SaferProducts screening on 2026-11-23 returned zero recall matches for GE Profile; confirm tank age separately using the rating-plate serial pattern. See Serial Number Lookup.
What Are 5 Direct Alternatives to GE Profile PH80S10BNY01?
Homeowners cross-shopping GE Profile PH80S10BNY01 frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Reclaim Energy MP80F-RC | Hybrid/Electric Heat Pump | 80 gal | 98 gal | 3.8 (-0.70) | 1,273 |
| VAUGHN THERMAL MP80F-RC | Hybrid/Electric Heat Pump | 80 gal | 98 gal | 3.8 (-0.70) | 1,273 |
| Smart Solar SSG2-ES 80 | Hybrid/Electric Heat Pump | 80 gal | 55 gal | 2.71 (-1.79) | 1,192 |
| A. O. Smith CAHP-80 2** | Hybrid/Electric Heat Pump | 81 gal | 95 gal | 3.88 (-0.62) | 1,279 |
| VAUGHN THERMAL MP80FHPT | Hybrid/Electric Heat Pump | 80 gal | 86 gal | 3.5 (-1.00) | 1,375 |
Who Is GE Profile PH80S10BNY01 Best For — and When Should You Pick Reclaim Energy MP80F-RC?
Evaluate whether GE Profile PH80S10BNY01's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.
Key Limitations & Exclusions
- GE Profile PH80S10BNY01 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 41 dBA; avoid mounting GE Profile PH80S10BNY01 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Sizing, Efficiency & Recall Answers for GE Profile PH80S10BNY01
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does GE Profile PH80S10BNY01 (4.5 UEF) compare to 2029 federal DOE floors?
Evaluated against May 6, 2029 10 CFR 430.32 thresholds, GE Profile PH80S10BNY01 records 4.5 UEF (Pass: +2.00 / +80.0%), placing #1 of 706 (top 0.4%) out of 706 certified Hybrid/Electric Heat Pump configurations.
Does GE Profile PH80S10BNY01 fit inside a tight hallway closet or low-headroom utility room?
GE Profile PH80S10BNY01 requires room for its 57.2 in. vertical shell and 21.5 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.5" d)), plus service access for annual sediment draining.
What power supply or fuel line specs govern GE Profile PH80S10BNY01?
For GE Profile PH80S10BNY01, plan a 240V circuit at 23A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.
What annual utility bill should homeowners budget for GE Profile PH80S10BNY01?
Using 1,102 kWh/yr, GE Profile PH80S10BNY01 generates an estimated $200/yr electric bill at 18.16 cents/kWh (ranging from $161/yr in Washington hydro tiers up to $520/yr in Hawaii)—use the custom rate slider above for your utility tariff.
What are the main drawbacks of GE Profile PH80S10BNY01 (4.5 UEF)?
GE Profile PH80S10BNY01 requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or Reclaim Energy MP80F-RC.
What hot-water delivery rating governs GE Profile PH80S10BNY01?
Rated for 101 gal FHR (+29 gal vs. 72 gal median), GE Profile PH80S10BNY01 prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.
Where do homeowners screen GE Profile PH80S10BNY01 for recalls and tank age?
Verified clean against 2026-11-23 CPSC recall feeds for GE Profile; use our browser-only serial decoder to inspect GE Profile PH80S10BNY01's age and warranty window.
What alternative models sit closest to GE Profile PH80S10BNY01 in the Hybrid/Electric Heat Pump class?
Closest peer in Hybrid/Electric Heat Pump is Reclaim Energy MP80F-RC (3.8 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)