Skip to main content
ENERGY STAR water heater model · PD 4480877

GE Profile PH80S10BPY01 Water Heater Specifications (4.4 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, GE Profile PH80S10BPY01 achieves a certified 4.4 UEF rating across its 80-gallon nominal tank, 101 gal First Hour Rating and ranks #4 of 706 in its 706-model cohort (PD 4480877), recording Pass: +1.90 / +76.0% under 2029 DOE rules. Rated annual electricity draw of 1,127 kWh/yr equates to roughly $205/yr ($2,047 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Reclaim Energy MP80F-RC (3.8 UEF).

Uniform Energy Factor
4.4 UEF
Cohort UEF Rank
#4 of 706 (top 0.6%)
First Hour Rating
101 gal
Storage Volume
80 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.90 / +76.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking GE Profile PH80S10BPY01 at 4.4 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50GE Profile PH80S10BPY01: 4.40
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows GE Profile PH80S10BPY01 relative to the cohort median.
Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, GE Profile PH80S10BPY01 logs 4.4 UEF and ranks #4 of 706.

Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), GE Profile PH80S10BPY01 holds a +1.90 UEF (+76.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,127 kWh/yr for GE Profile PH80S10BPY01 runs ~$205/yr vs. ~$979/yr for a 0.92 UEF electric tank. Acoustic output is 41 dBA (quieter than 81.2% of Hybrid/Electric Heat Pump models).

State electric sensitivity for GE Profile PH80S10BPY01: 10-year operating spend spans $1,649 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,317 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping GE Profile PH80S10BPY01 (4.4 UEF)? Check Reclaim Energy MP80F-RC (3.8 UEF, delta -0.60) and VAUGHN THERMAL MP80F-RC (3.8 UEF, delta -0.60).

Which Specs Set GE Profile PH80S10BPY01 Apart From Cohort Averages?

Ranked #4 of 706 (top 0.6%) inside the 706-model Hybrid/Electric Heat Pump cohort, GE Profile PH80S10BPY01 is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandGE Profile18 certified listingsENERGY STAR PD 4480877
Model NumberPH80S10BPY01Draw pattern: High-UsagePH80S10BPY01
Uniform Energy Factor (UEF)4.4+0.70 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)101 gal+29 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,127 kWh/yr+55 kWh/yr vs. 1,072 kWh/yr medianEst. $205/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency487%+58.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)57.2" H x 21.5" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.5" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 23 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR1234YFLower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Sound Pressure Level41 dBAtop 18.8% · quieter than 81.2% of Hybrid/Electric Heat Pump models · -8 dBA vs. 49 dBA medianIndoor placement check
Certification Date2025-07-30Certified 2025-07-30Markets: United States

How Do Regional kWh Prices Impact PH80S10BPY01 Over 10 Years?

Using EIA Table 5.6.A benchmarks, GE Profile PH80S10BPY01's 1,127 kWh/yr draw translates to roughly $205/yr on typical US residential bills.

Estimated Annual Electricity Cost by State Rate (1,127 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$205.00/yrHawaii$532.00/yrCalifornia$335.00/yrTexas$179.00/yrWashington$165.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $205/yr $2,047 $7,742
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $532/yr $5,317 $20,113
California 29.75 ¢/kWh ($0.2975) $335/yr $3,353 $12,682
Texas 15.91 ¢/kWh ($0.1591) $179/yr $1,793 $6,782
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $165/yr $1,649 $6,237
Estimated electricity spend (1,127 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should GE Profile Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC recall sweep recorded zero brand matches for GE Profile; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.

How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Reclaim Energy MP80F-RC Hybrid/Electric Heat Pump 80 gal 98 gal 3.8 (-0.60) 1,273
VAUGHN THERMAL MP80F-RC Hybrid/Electric Heat Pump 80 gal 98 gal 3.8 (-0.60) 1,273
Smart Solar SSG2-ES 80 Hybrid/Electric Heat Pump 80 gal 55 gal 2.71 (-1.69) 1,192
A. O. Smith CAHP-80 2** Hybrid/Electric Heat Pump 81 gal 95 gal 3.88 (-0.52) 1,279
VAUGHN THERMAL MP80FHPT Hybrid/Electric Heat Pump 80 gal 86 gal 3.5 (-0.90) 1,375

What Installation Caveats Apply Before Buying GE Profile PH80S10BPY01?

Even high-UEF units like GE Profile PH80S10BPY01 (4.4 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • GE Profile PH80S10BPY01 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 41 dBA; avoid mounting GE Profile PH80S10BPY01 directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing GE Profile PH80S10BPY01 Strong Fit — 4.4 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Reclaim Energy MP80F-RC footprint.

Frequently Asked Technical Questions: GE Profile PH80S10BPY01

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is GE Profile PH80S10BPY01 eligible for continued manufacture past May 6, 2029?

At 4.4 UEF, GE Profile PH80S10BPY01 achieves Pass: +1.90 / +76.0% for the 2029 DOE standard and stands #4 of 706 (top 0.6%) against Reclaim Energy MP80F-RC and VAUGHN THERMAL MP80F-RC.

How tall and wide is GE Profile PH80S10BPY01, and what service clearance is needed?

Physical dimensions for GE Profile PH80S10BPY01 are 57.2 in. height and 21.5 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.5" d)); verify stair turns and drain pan width before delivery.

Will GE Profile PH80S10BPY01 require upgrading household electrical panels or gas piping?

GE Profile PH80S10BPY01 draws 240V at 23A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

Is GE Profile PH80S10BPY01 economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $205/yr ($2,050 over 10 years) to power GE Profile PH80S10BPY01 at 1,127 kWh/yr under the 18.16 cents/kWh US average (ranging from $165/yr in Washington hydro tiers up to $532/yr in Hawaii).

Which installation bottlenecks limit GE Profile PH80S10BPY01?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, GE Profile PH80S10BPY01 drops into resistance mode more often.

How does GE Profile PH80S10BPY01 handle simultaneous showers and laundry?

Delivering 101 gal in the first hour (+29 gal vs. 72 gal median), GE Profile PH80S10BPY01 combines 80 gal tank storage with rapid burner/element recovery.

How long is the warranty on GE Profile PH80S10BPY01 and how do you decode its serial?

CPSC records show 0 active plumbing recalls for GE Profile as of 2026-11-23. Confirm install proof and serial manufacture year on GE Profile PH80S10BPY01 before calling service.

How do 2026 post-OBBBA rebates affect buying GE Profile PH80S10BPY01?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is Reclaim Energy MP80F-RC (3.8 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks