Skip to main content
ENERGY STAR water heater model · PD 4480872

GE Profile PJ80S10FPY01 Water Heater Specifications (3.5 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, GE Profile PJ80S10FPY01 achieves a certified 3.5 UEF rating across its 80-gallon nominal tank, 94 gal First Hour Rating and ranks #481 of 706 in its 706-model cohort (PD 4480872), recording Pass: +1.00 / +40.0% under 2029 DOE rules. Rated annual electricity draw of 1,417 kWh/yr equates to roughly $257/yr ($2,573 over 10 years) at 18.16 cents/kWh. Closest certified alternative is VAUGHN THERMAL MP80FHPT (3.5 UEF).

Uniform Energy Factor
3.5 UEF
Cohort UEF Rank
#481 of 706
First Hour Rating
94 gal
Storage Volume
80 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.00 / +40.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking GE Profile PJ80S10FPY01 at 3.5 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50GE Profile PJ80S10FPY01: 3.50
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows GE Profile PJ80S10FPY01 relative to the cohort median.
Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, GE Profile PJ80S10FPY01 logs 3.5 UEF and ranks #481 of 706.

Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), GE Profile PJ80S10FPY01 holds a +1.00 UEF (+40.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,417 kWh/yr for GE Profile PJ80S10FPY01 runs ~$257/yr vs. ~$979/yr for a 0.92 UEF electric tank. Acoustic output is 41 dBA (quieter than 81.2% of Hybrid/Electric Heat Pump models).

State electric sensitivity for GE Profile PJ80S10FPY01: 10-year operating spend spans $2,073 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,685 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping GE Profile PJ80S10FPY01 (3.5 UEF)? Check VAUGHN THERMAL MP80FHPT (3.5 UEF, at parity) and Reclaim Energy MP80F-RC (3.8 UEF, delta +0.30).

What Physical and Thermal Ratings Define GE Profile PJ80S10FPY01?

Positioning at #481 of 706 out of 706 Hybrid/Electric Heat Pump peers, GE Profile PJ80S10FPY01 pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandGE Profile18 certified listingsENERGY STAR PD 4480872
Model NumberPJ80S10FPY01Draw pattern: High-UsagePJ80S10FPY01
Uniform Energy Factor (UEF)3.5-0.20 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)94 gal+22 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,417 kWh/yr+345 kWh/yr vs. 1,072 kWh/yr medianEst. $257/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency402%-27.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)57.2" H x 21.5" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.5" D)Doorway & ceiling check
Electrical Circuit Requirements120 V / 7.5 A max120V plug-in retrofit circuit; slower heat-pump-only recoveryNEC / Branch circuit check
Heat Pump Refrigerant & GWPR1234YFLower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Sound Pressure Level41 dBAtop 18.8% · quieter than 81.2% of Hybrid/Electric Heat Pump models · -8 dBA vs. 49 dBA medianIndoor placement check
Certification Date2025-07-30Certified 2025-07-30Markets: Canada

Why Do State Utility Rates Shift PJ80S10FPY01 Running Costs?

Consuming 1,417 kWh annually puts GE Profile PJ80S10FPY01 near $257/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Estimated Annual Electricity Cost by State Rate (1,417 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$257.00/yrHawaii$669.00/yrCalifornia$422.00/yrTexas$225.00/yrWashington$207.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $257/yr $2,573 $7,217
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $669/yr $6,685 $18,749
California 29.75 ¢/kWh ($0.2975) $422/yr $4,216 $11,823
Texas 15.91 ¢/kWh ($0.1591) $225/yr $2,254 $6,323
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $207/yr $2,073 $5,814
Estimated electricity spend (1,417 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any GE Profile Series Triggered CPSC Recalls?

SaferProducts screening on 2026-11-23 returned zero recall matches for GE Profile; confirm tank age separately using the rating-plate serial pattern. See Serial Number Lookup.

What Are 5 Direct Alternatives to GE Profile PJ80S10FPY01?

Homeowners cross-shopping GE Profile PJ80S10FPY01 frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
VAUGHN THERMAL MP80FHPT Hybrid/Electric Heat Pump 80 gal 86 gal 3.5 (at parity) 1,375
Reclaim Energy MP80F-RC Hybrid/Electric Heat Pump 80 gal 98 gal 3.8 (+0.30) 1,273
Smart Solar SSG2-ES 80 Hybrid/Electric Heat Pump 80 gal 55 gal 2.71 (-0.79) 1,192
A. O. Smith CAHP-80 2** Hybrid/Electric Heat Pump 81 gal 95 gal 3.88 (+0.38) 1,279
VAUGHN THERMAL MP80F-RC Hybrid/Electric Heat Pump 80 gal 98 gal 3.8 (+0.30) 1,273

What Installation Caveats Apply Before Buying GE Profile PJ80S10FPY01?

Even high-UEF units like GE Profile PJ80S10FPY01 (3.5 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • GE Profile PJ80S10FPY01 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 41 dBA; avoid mounting GE Profile PJ80S10FPY01 directly beside quiet bedrooms.
  • Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing GE Profile PJ80S10FPY01 Strong Fit — 3.5 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare VAUGHN THERMAL MP80FHPT footprint.

Sizing, Efficiency & Recall Answers for GE Profile PJ80S10FPY01

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is GE Profile PJ80S10FPY01 eligible for continued manufacture past May 6, 2029?

At 3.5 UEF, GE Profile PJ80S10FPY01 achieves Pass: +1.00 / +40.0% for the 2029 DOE standard and stands #481 of 706 against VAUGHN THERMAL MP80FHPT and Reclaim Energy MP80F-RC.

How tall and wide is GE Profile PJ80S10FPY01, and what service clearance is needed?

Physical dimensions for GE Profile PJ80S10FPY01 are 57.2 in. height and 21.5 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.5" d)); verify stair turns and drain pan width before delivery.

Will GE Profile PJ80S10FPY01 require upgrading household electrical panels or gas piping?

GE Profile PJ80S10FPY01 draws 120V at 7.5A max (120V plug-in retrofit circuit; slower heat-pump-only recovery); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

Is GE Profile PJ80S10FPY01 economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $257/yr ($2,570 over 10 years) to power GE Profile PJ80S10FPY01 at 1,417 kWh/yr under the 18.16 cents/kWh US average (ranging from $207/yr in Washington hydro tiers up to $669/yr in Hawaii).

Which installation bottlenecks limit GE Profile PJ80S10FPY01?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, GE Profile PJ80S10FPY01 drops into resistance mode more often.

How does GE Profile PJ80S10FPY01 handle simultaneous showers and laundry?

Delivering 94 gal in the first hour (+22 gal vs. 72 gal median), GE Profile PJ80S10FPY01 combines 80 gal tank storage with rapid burner/element recovery.

How long is the warranty on GE Profile PJ80S10FPY01 and how do you decode its serial?

CPSC records show 0 active plumbing recalls for GE Profile as of 2026-11-23. Confirm install proof and serial manufacture year on GE Profile PJ80S10FPY01 before calling service.

How do 2026 post-OBBBA rebates affect buying GE Profile PJ80S10FPY01?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is VAUGHN THERMAL MP80FHPT (3.5 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks