LG APHWC501D Water Heater Specifications (3.93 UEF)
Engineered as a Electric Hybrid/Electric Heat Pump unit, LG APHWC501D achieves a certified 3.93 UEF rating across its 53-gallon nominal tank, 76 gal First Hour Rating and ranks #141 of 706 in its 706-model cohort (PD 3417697), recording Pass: +1.63 / +70.9% under 2029 DOE rules. Rated annual electricity draw of 1,262 kWh/yr equates to roughly $229/yr ($2,292 over 10 years) at 18.16 cents/kWh. Closest certified alternative is GREE GRS-3.0Pd/TD50GANhA-D (4.02 UEF).
- Uniform Energy Factor
- 3.93 UEF
- Cohort UEF Rank
- #141 of 706 (top 20.3%)
- First Hour Rating
- 76 gal
- Storage Volume
- 53 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.63 / +70.9%

Within the 706-unit Hybrid/Electric Heat Pump cohort, LG APHWC501D logs 3.93 UEF and ranks #141 of 706.
Against 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF), LG APHWC501D holds a +1.63 UEF (+70.9%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,262 kWh/yr for LG APHWC501D runs ~$229/yr vs. ~$979/yr for a 0.92 UEF electric tank.
State electric sensitivity for LG APHWC501D: 10-year operating spend spans $1,846 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,954 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Cross-shopping LG APHWC501D (3.93 UEF)? Check GREE GRS-3.0Pd/TD50GANhA-D (4.02 UEF, delta +0.09) and VAUGHN THERMAL MP55FHPT (3.3 UEF, delta -0.63).
What Physical and Thermal Ratings Define LG APHWC501D?
Positioning at #141 of 706 (top 20.3%) out of 706 Hybrid/Electric Heat Pump peers, LG APHWC501D pairs measured UEF performance with specific clearance and wiring rules.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | LG | 12 certified listings | ENERGY STAR PD 3417697 |
| Model Number | APHWC501D | Draw pattern: High-Usage | APHWC501D |
| Uniform Energy Factor (UEF) | 3.93 | +0.23 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 76 gal | +4 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,262 kWh/yr | +190 kWh/yr vs. 1,072 kWh/yr median | Est. $229/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 410% | -19.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 47.6" H x 19.7" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (19.7" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 24 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2024-05-10 | Certified 2024-05-10 | Markets: United States |
Why Do State Utility Rates Shift APHWC501D Running Costs?
Consuming 1,262 kWh annually puts LG APHWC501D near $229/yr at US baseline tariffs, with multi-state EIA comparisons charted below.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $229/yr | $2,292 | $7,498 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $595/yr | $5,954 | $19,481 |
| California | 29.75 ¢/kWh ($0.2975) | $375/yr | $3,754 | $12,284 |
| Texas | 15.91 ¢/kWh ($0.1591) | $201/yr | $2,008 | $6,569 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $185/yr | $1,846 | $6,041 |
Have Any LG Series Triggered CPSC Recalls?
SaferProducts screening on 2026-11-23 returned zero recall matches for LG; confirm tank age separately using the rating-plate serial pattern. See Serial Number Lookup.
What Are 5 Direct Alternatives to LG APHWC501D?
Homeowners cross-shopping LG APHWC501D frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| GREE GRS-3.0Pd/TD50GANhA-D | Hybrid/Electric Heat Pump | 55 gal | 80 gal | 4.02 (+0.09) | 1,234 |
| VAUGHN THERMAL MP55FHPT | Hybrid/Electric Heat Pump | 55 gal | 62 gal | 3.3 (-0.63) | 982 |
| GE Profile PK50S10FNY01 | Hybrid/Electric Heat Pump | 50 gal | 60 gal | 4.2 (+0.27) | 773 |
| Hubbell ME65HPT | Hybrid/Electric Heat Pump | 57 gal | 70 gal | 3.34 (-0.59) | 974 |
| GE Profile PH50S10BPY01 | Hybrid/Electric Heat Pump | 50 gal | 77 gal | 4.3 (+0.37) | 1,154 |
Who Is LG APHWC501D Best For — and When Should You Pick GREE GRS-3.0Pd/TD50GANhA-D?
Evaluate whether LG APHWC501D's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.
Key Limitations & Exclusions
- LG APHWC501D needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting LG APHWC501D directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Sizing, Efficiency & Recall Answers for LG APHWC501D
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does LG APHWC501D (3.93 UEF) compare to 2029 federal DOE floors?
Evaluated against May 6, 2029 10 CFR 430.32 thresholds, LG APHWC501D records 3.93 UEF (Pass: +1.63 / +70.9%), placing #141 of 706 (top 20.3%) out of 706 certified Hybrid/Electric Heat Pump configurations.
Does LG APHWC501D fit inside a tight hallway closet or low-headroom utility room?
LG APHWC501D requires room for its 47.6 in. vertical shell and 19.7 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (19.7" d)), plus service access for annual sediment draining.
What power supply or fuel line specs govern LG APHWC501D?
For LG APHWC501D, plan a 240V circuit at 24A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.
What annual utility bill should homeowners budget for LG APHWC501D?
Using 1,262 kWh/yr, LG APHWC501D generates an estimated $229/yr electric bill at 18.16 cents/kWh (ranging from $185/yr in Washington hydro tiers up to $595/yr in Hawaii)—use the custom rate slider above for your utility tariff.
What are the main drawbacks of LG APHWC501D (3.93 UEF)?
LG APHWC501D requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or GREE GRS-3.0Pd/TD50GANhA-D.
What hot-water delivery rating governs LG APHWC501D?
Rated for 76 gal FHR (+4 gal vs. 72 gal median), LG APHWC501D prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.
Where do homeowners screen LG APHWC501D for recalls and tank age?
Verified clean against 2026-11-23 CPSC recall feeds for LG; use our browser-only serial decoder to inspect LG APHWC501D's age and warranty window.
What alternative models sit closest to LG APHWC501D in the Hybrid/Electric Heat Pump class?
Closest peer in Hybrid/Electric Heat Pump is GREE GRS-3.0Pd/TD50GANhA-D (4.02 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)