Skip to main content
ENERGY STAR water heater model · PD 3417697

LG APHWC501D Water Heater Specifications (3.93 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, LG APHWC501D achieves a certified 3.93 UEF rating across its 53-gallon nominal tank, 76 gal First Hour Rating and ranks #141 of 706 in its 706-model cohort (PD 3417697), recording Pass: +1.63 / +70.9% under 2029 DOE rules. Rated annual electricity draw of 1,262 kWh/yr equates to roughly $229/yr ($2,292 over 10 years) at 18.16 cents/kWh. Closest certified alternative is GREE GRS-3.0Pd/TD50GANhA-D (4.02 UEF).

Uniform Energy Factor
3.93 UEF
Cohort UEF Rank
#141 of 706 (top 20.3%)
First Hour Rating
76 gal
Storage Volume
53 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.63 / +70.9%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking LG APHWC501D at 3.93 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30LG APHWC501D: 3.93
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows LG APHWC501D relative to the cohort median.
Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, LG APHWC501D logs 3.93 UEF and ranks #141 of 706.

Against 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF), LG APHWC501D holds a +1.63 UEF (+70.9%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,262 kWh/yr for LG APHWC501D runs ~$229/yr vs. ~$979/yr for a 0.92 UEF electric tank.

State electric sensitivity for LG APHWC501D: 10-year operating spend spans $1,846 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,954 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping LG APHWC501D (3.93 UEF)? Check GREE GRS-3.0Pd/TD50GANhA-D (4.02 UEF, delta +0.09) and VAUGHN THERMAL MP55FHPT (3.3 UEF, delta -0.63).

What Physical and Thermal Ratings Define LG APHWC501D?

Positioning at #141 of 706 (top 20.3%) out of 706 Hybrid/Electric Heat Pump peers, LG APHWC501D pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandLG12 certified listingsENERGY STAR PD 3417697
Model NumberAPHWC501DDraw pattern: High-UsageAPHWC501D
Uniform Energy Factor (UEF)3.93+0.23 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)76 gal+4 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,262 kWh/yr+190 kWh/yr vs. 1,072 kWh/yr medianEst. $229/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency410%-19.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)47.6" H x 19.7" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (19.7" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 24 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2024-05-10Certified 2024-05-10Markets: United States

Why Do State Utility Rates Shift APHWC501D Running Costs?

Consuming 1,262 kWh annually puts LG APHWC501D near $229/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Estimated Annual Electricity Cost by State Rate (1,262 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$229.00/yrHawaii$595.00/yrCalifornia$375.00/yrTexas$201.00/yrWashington$185.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $229/yr $2,292 $7,498
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $595/yr $5,954 $19,481
California 29.75 ¢/kWh ($0.2975) $375/yr $3,754 $12,284
Texas 15.91 ¢/kWh ($0.1591) $201/yr $2,008 $6,569
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $185/yr $1,846 $6,041
Estimated electricity spend (1,262 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any LG Series Triggered CPSC Recalls?

SaferProducts screening on 2026-11-23 returned zero recall matches for LG; confirm tank age separately using the rating-plate serial pattern. See Serial Number Lookup.

What Are 5 Direct Alternatives to LG APHWC501D?

Homeowners cross-shopping LG APHWC501D frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
GREE GRS-3.0Pd/TD50GANhA-D Hybrid/Electric Heat Pump 55 gal 80 gal 4.02 (+0.09) 1,234
VAUGHN THERMAL MP55FHPT Hybrid/Electric Heat Pump 55 gal 62 gal 3.3 (-0.63) 982
GE Profile PK50S10FNY01 Hybrid/Electric Heat Pump 50 gal 60 gal 4.2 (+0.27) 773
Hubbell ME65HPT Hybrid/Electric Heat Pump 57 gal 70 gal 3.34 (-0.59) 974
GE Profile PH50S10BPY01 Hybrid/Electric Heat Pump 50 gal 77 gal 4.3 (+0.37) 1,154

Who Is LG APHWC501D Best For — and When Should You Pick GREE GRS-3.0Pd/TD50GANhA-D?

Evaluate whether LG APHWC501D's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

Key Limitations & Exclusions

  • LG APHWC501D needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting LG APHWC501D directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing LG APHWC501D Strong Fit — 3.93 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare GREE GRS-3.0Pd/TD50GANhA-D footprint.

Sizing, Efficiency & Recall Answers for LG APHWC501D

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does LG APHWC501D (3.93 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, LG APHWC501D records 3.93 UEF (Pass: +1.63 / +70.9%), placing #141 of 706 (top 20.3%) out of 706 certified Hybrid/Electric Heat Pump configurations.

Does LG APHWC501D fit inside a tight hallway closet or low-headroom utility room?

LG APHWC501D requires room for its 47.6 in. vertical shell and 19.7 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (19.7" d)), plus service access for annual sediment draining.

What power supply or fuel line specs govern LG APHWC501D?

For LG APHWC501D, plan a 240V circuit at 24A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.

What annual utility bill should homeowners budget for LG APHWC501D?

Using 1,262 kWh/yr, LG APHWC501D generates an estimated $229/yr electric bill at 18.16 cents/kWh (ranging from $185/yr in Washington hydro tiers up to $595/yr in Hawaii)—use the custom rate slider above for your utility tariff.

What are the main drawbacks of LG APHWC501D (3.93 UEF)?

LG APHWC501D requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or GREE GRS-3.0Pd/TD50GANhA-D.

What hot-water delivery rating governs LG APHWC501D?

Rated for 76 gal FHR (+4 gal vs. 72 gal median), LG APHWC501D prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

Where do homeowners screen LG APHWC501D for recalls and tank age?

Verified clean against 2026-11-23 CPSC recall feeds for LG; use our browser-only serial decoder to inspect LG APHWC501D's age and warranty window.

What alternative models sit closest to LG APHWC501D in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is GREE GRS-3.0Pd/TD50GANhA-D (4.02 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks