VAUGHN THERMAL MP55FHPT Water Heater Specifications (3.3 UEF)
Engineered as a Electric Hybrid/Electric Heat Pump unit, VAUGHN THERMAL MP55FHPT achieves a certified 3.3 UEF rating across its 55-gallon nominal tank, 62 gal First Hour Rating and ranks #644 of 706 in its 706-model cohort (PD 4518062), recording Pass: +1.00 / +43.5% under 2029 DOE rules. Rated annual electricity draw of 982 kWh/yr equates to roughly $178/yr ($1,783 over 10 years) at 18.16 cents/kWh. Closest certified alternative is GREE GRS-3.0Pd/TD50GANhA-D (4.02 UEF).
- Uniform Energy Factor
- 3.3 UEF
- Cohort UEF Rank
- #644 of 706
- First Hour Rating
- 62 gal
- Storage Volume
- 55 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.00 / +43.5%

Within the 706-unit Hybrid/Electric Heat Pump cohort, VAUGHN THERMAL MP55FHPT logs 3.3 UEF and ranks #644 of 706.
Against 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF), VAUGHN THERMAL MP55FHPT holds a +1.00 UEF (+43.5%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 982 kWh/yr for VAUGHN THERMAL MP55FHPT runs ~$178/yr vs. ~$640/yr for a 0.92 UEF electric tank.
State electric sensitivity for VAUGHN THERMAL MP55FHPT: 10-year operating spend spans $1,437 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,633 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Cross-shopping VAUGHN THERMAL MP55FHPT (3.3 UEF)? Check GREE GRS-3.0Pd/TD50GANhA-D (4.02 UEF, delta +0.72) and Hubbell ME65HPT (3.34 UEF, delta +0.04).
How Do VAUGHN THERMAL MP55FHPT Specs Compare to Hybrid/Electric Heat Pump Medians?
VAUGHN THERMAL MP55FHPT places #644 of 706 across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | VAUGHN THERMAL | 13 certified listings | ENERGY STAR PD 4518062 |
| Model Number | MP55FHPT | Draw pattern: Medium-Usage | MP55FHPT |
| Uniform Energy Factor (UEF) | 3.3 | -0.40 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 62 gal | -10 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 982 kWh/yr | -90 kWh/yr vs. 1,072 kWh/yr median | Est. $178/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 364% | -65.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 54.5" H x 30" D | Fits standard 72 in. basement/garage clearance; tight at 28 in. door (30" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 23 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Sound Pressure Level | 54 dBA | +5 dBA vs. 49 dBA median | Indoor placement check |
| Certification Date | 2025-12-12 | Certified 2025-12-12 | Markets: United States, Canada |
What Does MP55FHPT Cost to Operate Across State Electricity Rates?
At 982 kWh/yr, VAUGHN THERMAL MP55FHPT runs roughly $178/yr on the EIA national average tier under August 2026 Table 5.6.A rates.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $178/yr | $1,783 | $4,613 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $463/yr | $4,633 | $11,984 |
| California | 29.75 ¢/kWh ($0.2975) | $292/yr | $2,921 | $7,556 |
| Texas | 15.91 ¢/kWh ($0.1591) | $156/yr | $1,562 | $4,041 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $144/yr | $1,437 | $3,716 |
Are There Active CPSC Safety Recalls for VAUGHN THERMAL Water Heaters?
Zero active CPSC recalls matched VAUGHN THERMAL in our 2026-11-23 SaferProducts sweep; verify your individual tank date code via our lookup tool. See Serial Number Lookup.
Which Certified Water Heaters Match MP55FHPT Most Closely?
These 5 competing Hybrid/Electric Heat Pump units sit nearest to VAUGHN THERMAL MP55FHPT by storage capacity and 3.3 UEF rating.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| GREE GRS-3.0Pd/TD50GANhA-D | Hybrid/Electric Heat Pump | 55 gal | 80 gal | 4.02 (+0.72) | 1,234 |
| Hubbell ME65HPT | Hybrid/Electric Heat Pump | 57 gal | 70 gal | 3.34 (+0.04) | 974 |
| Noritz NHP65 | Hybrid/Electric Heat Pump | 57 gal | 70 gal | 3.34 (+0.04) | 974 |
| LG APHWC501D | Hybrid/Electric Heat Pump | 53 gal | 76 gal | 3.93 (+0.63) | 1,262 |
| LG APHWC501L | Hybrid/Electric Heat Pump | 53 gal | 76 gal | 3.93 (+0.63) | 1,262 |
What Installation Caveats Apply Before Buying VAUGHN THERMAL MP55FHPT?
Even high-UEF units like VAUGHN THERMAL MP55FHPT (3.3 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.
Key Limitations & Exclusions
- VAUGHN THERMAL MP55FHPT needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 54 dBA; avoid mounting VAUGHN THERMAL MP55FHPT directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
What Are the Key Questions About VAUGHN THERMAL MP55FHPT?
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Is VAUGHN THERMAL MP55FHPT eligible for continued manufacture past May 6, 2029?
At 3.3 UEF, VAUGHN THERMAL MP55FHPT achieves Pass: +1.00 / +43.5% for the 2029 DOE standard and stands #644 of 706 against GREE GRS-3.0Pd/TD50GANhA-D and Hubbell ME65HPT.
How tall and wide is VAUGHN THERMAL MP55FHPT, and what service clearance is needed?
Physical dimensions for VAUGHN THERMAL MP55FHPT are 54.5 in. height and 30 in. diameter (fits standard 72 in. basement/garage clearance; tight at 28 in. door (30" d)); verify stair turns and drain pan width before delivery.
Will VAUGHN THERMAL MP55FHPT require upgrading household electrical panels or gas piping?
VAUGHN THERMAL MP55FHPT draws 240V at 23A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.
Is VAUGHN THERMAL MP55FHPT economical to operate at 18.16 cents/kWh US electric rates?
Expect roughly $178/yr ($1,780 over 10 years) to power VAUGHN THERMAL MP55FHPT at 982 kWh/yr under the 18.16 cents/kWh US average (ranging from $144/yr in Washington hydro tiers up to $463/yr in Hawaii).
Which installation bottlenecks limit VAUGHN THERMAL MP55FHPT?
If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, VAUGHN THERMAL MP55FHPT drops into resistance mode more often.
How does VAUGHN THERMAL MP55FHPT handle simultaneous showers and laundry?
Delivering 62 gal in the first hour (-10 gal vs. 72 gal median), VAUGHN THERMAL MP55FHPT combines 55 gal tank storage with rapid burner/element recovery.
How long is the warranty on VAUGHN THERMAL MP55FHPT and how do you decode its serial?
CPSC records show 0 active plumbing recalls for VAUGHN THERMAL as of 2026-11-23. Confirm install proof and serial manufacture year on VAUGHN THERMAL MP55FHPT before calling service.
How do 2026 post-OBBBA rebates affect buying VAUGHN THERMAL MP55FHPT?
Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is GREE GRS-3.0Pd/TD50GANhA-D (4.02 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)