Skip to main content
ENERGY STAR water heater model · PD 3417698

LG APHWC501L Water Heater Specifications (3.93 UEF)

With PD 3417698 certification, LG APHWC501L (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.93 UEF rating across its 53-gallon nominal tank, 76 gal First Hour Rating, standing #141 of 706 across 706 peers with Pass: +1.63 / +70.9% for May 6, 2029. Rated annual electricity draw of 1,262 kWh/yr equates to roughly $229/yr ($2,292 over 10 years) at 18.16 cents/kWh. Closest certified alternative is GREE GRS-3.0Pd/TD50GANhA-D (4.02 UEF).

Uniform Energy Factor
3.93 UEF
Cohort UEF Rank
#141 of 706 (top 20.3%)
First Hour Rating
76 gal
Storage Volume
53 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.63 / +70.9%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking LG APHWC501L at 3.93 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30LG APHWC501L: 3.93
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows LG APHWC501L relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places LG APHWC501L at 3.93 UEF (#141 of 706; +0.23 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: LG APHWC501L stands +1.63 UEF (+70.9%) relative to 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,262 kWh/yr for LG APHWC501L runs ~$229/yr vs. ~$979/yr for a 0.92 UEF electric tank.

State electric sensitivity for LG APHWC501L: 10-year operating spend spans $1,846 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,954 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, GREE GRS-3.0Pd/TD50GANhA-D (4.02 UEF, delta +0.09) and VAUGHN THERMAL MP55FHPT (3.3 UEF, delta -0.63) bracket LG APHWC501L.

Which Specs Set LG APHWC501L Apart From Cohort Averages?

Ranked #141 of 706 (top 20.3%) inside the 706-model Hybrid/Electric Heat Pump cohort, LG APHWC501L is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandLG12 certified listingsENERGY STAR PD 3417698
Model NumberAPHWC501LDraw pattern: High-UsageAPHWC501L
Uniform Energy Factor (UEF)3.93+0.23 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)76 gal+4 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,262 kWh/yr+190 kWh/yr vs. 1,072 kWh/yr medianEst. $229/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency410%-19.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)47.6" H x 19.7" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (19.7" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 24 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2024-05-10Certified 2024-05-10Markets: United States

How Do Regional kWh Prices Impact APHWC501L Over 10 Years?

Using EIA Table 5.6.A benchmarks, LG APHWC501L's 1,262 kWh/yr draw translates to roughly $229/yr on typical US residential bills.

Estimated Annual Electricity Cost by State Rate (1,262 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$229.00/yrHawaii$595.00/yrCalifornia$375.00/yrTexas$201.00/yrWashington$185.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $229/yr $2,292 $7,498
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $595/yr $5,954 $19,481
California 29.75 ¢/kWh ($0.2975) $375/yr $3,754 $12,284
Texas 15.91 ¢/kWh ($0.1591) $201/yr $2,008 $6,569
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $185/yr $1,846 $6,041
Estimated electricity spend (1,262 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should LG Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC recall sweep recorded zero brand matches for LG; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.

How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
GREE GRS-3.0Pd/TD50GANhA-D Hybrid/Electric Heat Pump 55 gal 80 gal 4.02 (+0.09) 1,234
VAUGHN THERMAL MP55FHPT Hybrid/Electric Heat Pump 55 gal 62 gal 3.3 (-0.63) 982
GE Profile PK50S10FNY01 Hybrid/Electric Heat Pump 50 gal 60 gal 4.2 (+0.27) 773
Hubbell ME65HPT Hybrid/Electric Heat Pump 57 gal 70 gal 3.34 (-0.59) 974
GE Profile PH50S10BPY01 Hybrid/Electric Heat Pump 50 gal 77 gal 4.3 (+0.37) 1,154

When Should Homeowners Skip LG APHWC501L (Hybrid/Electric Heat Pump)?

Check LG APHWC501L's mechanical constraints—including utility space, Electric capacity, and Pass: +1.63 / +70.9% status—against typical residential installations.

Key Limitations & Exclusions

  • LG APHWC501L needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting LG APHWC501L directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing LG APHWC501L Strong Fit — 3.93 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare GREE GRS-3.0Pd/TD50GANhA-D footprint.

Frequently Asked Technical Questions: LG APHWC501L

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will LG APHWC501L stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.93 UEF, LG APHWC501L shows Pass: +1.63 / +70.9% relative to May 6, 2029 federal DOE limits while placing #141 of 706 (top 20.3%) among 706 Hybrid/Electric Heat Pump peers like GREE GRS-3.0Pd/TD50GANhA-D.

Will LG APHWC501L fit through a standard utility door and 72-inch basement ceiling?

Measuring 47.6 in. tall by 19.7 in. diameter, LG APHWC501L notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (19.7" d). Reserve space above the jacket for T&P piping and anode removal.

Do existing utility hookups support LG APHWC501L during replacement?

Electrical specs for LG APHWC501L call for 240V at 24A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

What is the estimated 10-year operating spend for LG APHWC501L?

At 18.16 cents/kWh national residential pricing, LG APHWC501L's 1,262 kWh/yr draw equals roughly $229 annually or $2,290 across a 10-year horizon (ranging from $185/yr in Washington hydro tiers up to $595/yr in Hawaii).

When is LG APHWC501L a poor fit for a residential replacement?

Avoid placing LG APHWC501L directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

What First Hour Rating or flow capacity does LG APHWC501L deliver?

With 76 gal FHR (+4 gal vs. 72 gal median), LG APHWC501L fits larger 3–5 person homes cleanly.

How do you verify manufacturing age and recall status on LG APHWC501L?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for LG; verify exact manufacturing week for LG APHWC501L using the Serial Number Lookup tool.

Does LG APHWC501L qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for LG APHWC501L. Closest peer in Hybrid/Electric Heat Pump is GREE GRS-3.0Pd/TD50GANhA-D (4.02 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks