Skip to main content
ENERGY STAR water heater model · PD 4520749

LG APHWC502D Water Heater Specifications (4.2 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, LG APHWC502D (Electric) achieves a certified 4.2 UEF rating across its 53-gallon nominal tank, 81 gal First Hour Rating (rank #10 of 706, PD 4520749) and verifies as Pass: +1.90 / +82.6% for 2029 DOE floors. Rated annual electricity draw of 1,181 kWh/yr equates to roughly $214/yr ($2,145 over 10 years) at 18.16 cents/kWh. Closest certified alternative is GREE GRS-3.0Pd/TD50GANhA-D (4.02 UEF).

Uniform Energy Factor
4.2 UEF
Cohort UEF Rank
#10 of 706 (top 2.3%)
First Hour Rating
81 gal
Storage Volume
53 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.90 / +82.6%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking LG APHWC502D at 4.2 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30LG APHWC502D: 4.20
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows LG APHWC502D relative to the cohort median.
Efficiency comparison & rule summary

LG APHWC502D records 4.2 UEF efficiency, putting it #10 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: LG APHWC502D exceeds 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.90 UEF (+82.6%). At EIA August 2026 national rates (18.16 cents/kWh), 1,181 kWh/yr for LG APHWC502D runs ~$214/yr vs. ~$979/yr for a 0.92 UEF electric tank.

State electric sensitivity for LG APHWC502D: 10-year operating spend spans $1,728 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,572 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside LG APHWC502D (4.2 UEF) are GREE GRS-3.0Pd/TD50GANhA-D (4.02 UEF, delta -0.18) and VAUGHN THERMAL MP55FHPT (3.3 UEF, delta -0.90).

How Do LG APHWC502D Specs Compare to Hybrid/Electric Heat Pump Medians?

LG APHWC502D places #10 of 706 (top 2.3%) across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandLG12 certified listingsENERGY STAR PD 4520749
Model NumberAPHWC502DDraw pattern: High-UsageAPHWC502D
Uniform Energy Factor (UEF)4.2+0.50 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)81 gal+9 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,181 kWh/yr+109 kWh/yr vs. 1,072 kWh/yr medianEst. $214/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency440%+11.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)47.6" H x 19.7" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (19.7" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 24 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-02-25Certified 2026-02-25Markets: United States

What Does APHWC502D Cost to Operate Across State Electricity Rates?

At 1,181 kWh/yr, LG APHWC502D runs roughly $214/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Estimated Annual Electricity Cost by State Rate (1,181 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$214.00/yrHawaii$557.00/yrCalifornia$351.00/yrTexas$188.00/yrWashington$173.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $214/yr $2,145 $7,647
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $557/yr $5,572 $19,867
California 29.75 ¢/kWh ($0.2975) $351/yr $3,513 $12,528
Texas 15.91 ¢/kWh ($0.1591) $188/yr $1,879 $6,700
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $173/yr $1,728 $6,161
Estimated electricity spend (1,181 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for LG Water Heaters?

Zero active CPSC recalls matched LG in our 2026-11-23 SaferProducts sweep; verify your individual tank date code via our lookup tool. See Serial Number Lookup.

Which Certified Water Heaters Match APHWC502D Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to LG APHWC502D by storage capacity and 4.2 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
GREE GRS-3.0Pd/TD50GANhA-D Hybrid/Electric Heat Pump 55 gal 80 gal 4.02 (-0.18) 1,234
VAUGHN THERMAL MP55FHPT Hybrid/Electric Heat Pump 55 gal 62 gal 3.3 (-0.90) 982
GE Profile PK50S10FNY01 Hybrid/Electric Heat Pump 50 gal 60 gal 4.2 (at parity) 773
Hubbell ME65HPT Hybrid/Electric Heat Pump 57 gal 70 gal 3.34 (-0.86) 974
GE Profile PH50S10BPY01 Hybrid/Electric Heat Pump 50 gal 77 gal 4.3 (+0.10) 1,154

What Installation Caveats Apply Before Buying LG APHWC502D?

Even high-UEF units like LG APHWC502D (4.2 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • LG APHWC502D needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting LG APHWC502D directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing LG APHWC502D Strong Fit — 4.2 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare GREE GRS-3.0Pd/TD50GANhA-D footprint.

What Are the Key Questions About LG APHWC502D?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is LG APHWC502D eligible for continued manufacture past May 6, 2029?

At 4.2 UEF, LG APHWC502D achieves Pass: +1.90 / +82.6% for the 2029 DOE standard and stands #10 of 706 (top 2.3%) against GREE GRS-3.0Pd/TD50GANhA-D and VAUGHN THERMAL MP55FHPT.

How tall and wide is LG APHWC502D, and what service clearance is needed?

Physical dimensions for LG APHWC502D are 47.6 in. height and 19.7 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (19.7" d)); verify stair turns and drain pan width before delivery.

Will LG APHWC502D require upgrading household electrical panels or gas piping?

LG APHWC502D draws 240V at 24A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

Is LG APHWC502D economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $214/yr ($2,140 over 10 years) to power LG APHWC502D at 1,181 kWh/yr under the 18.16 cents/kWh US average (ranging from $173/yr in Washington hydro tiers up to $557/yr in Hawaii).

Which installation bottlenecks limit LG APHWC502D?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, LG APHWC502D drops into resistance mode more often.

How does LG APHWC502D handle simultaneous showers and laundry?

Delivering 81 gal in the first hour (+9 gal vs. 72 gal median), LG APHWC502D combines 53 gal tank storage with rapid burner/element recovery.

How long is the warranty on LG APHWC502D and how do you decode its serial?

CPSC records show 0 active plumbing recalls for LG as of 2026-11-23. Confirm install proof and serial manufacture year on LG APHWC502D before calling service.

How do 2026 post-OBBBA rebates affect buying LG APHWC502D?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is GREE GRS-3.0Pd/TD50GANhA-D (4.02 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks