Skip to main content
ENERGY STAR water heater model · PD 3417588

LG APHWC502M Water Heater Specifications (4.2 UEF)

With PD 3417588 certification, LG APHWC502M (Hybrid/Electric Heat Pump, Electric) achieves a certified 4.2 UEF rating across its 53-gallon nominal tank, 81 gal First Hour Rating, standing #10 of 706 across 706 peers with Pass: +1.90 / +82.6% for May 6, 2029. Rated annual electricity draw of 1,181 kWh/yr equates to roughly $214/yr ($2,145 over 10 years) at 18.16 cents/kWh. Closest certified alternative is GREE GRS-3.0Pd/TD50GANhA-D (4.02 UEF).

Uniform Energy Factor
4.2 UEF
Cohort UEF Rank
#10 of 706 (top 2.3%)
First Hour Rating
81 gal
Storage Volume
53 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.90 / +82.6%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking LG APHWC502M at 4.2 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30LG APHWC502M: 4.20
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows LG APHWC502M relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places LG APHWC502M at 4.2 UEF (#10 of 706; +0.50 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: LG APHWC502M stands +1.90 UEF (+82.6%) relative to 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,181 kWh/yr for LG APHWC502M runs ~$214/yr vs. ~$979/yr for a 0.92 UEF electric tank.

State electric sensitivity for LG APHWC502M: 10-year operating spend spans $1,728 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,572 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, GREE GRS-3.0Pd/TD50GANhA-D (4.02 UEF, delta -0.18) and VAUGHN THERMAL MP55FHPT (3.3 UEF, delta -0.90) bracket LG APHWC502M.

What Physical and Thermal Ratings Define LG APHWC502M?

Positioning at #10 of 706 (top 2.3%) out of 706 Hybrid/Electric Heat Pump peers, LG APHWC502M pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandLG12 certified listingsENERGY STAR PD 3417588
Model NumberAPHWC502MDraw pattern: High-UsageAPHWC502M
Uniform Energy Factor (UEF)4.2+0.50 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)81 gal+9 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,181 kWh/yr+109 kWh/yr vs. 1,072 kWh/yr medianEst. $214/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency440%+11.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)47.6" H x 19.7" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (19.7" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 24 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-02-10Certified 2026-02-10Markets: United States

Why Do State Utility Rates Shift APHWC502M Running Costs?

Consuming 1,181 kWh annually puts LG APHWC502M near $214/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Estimated Annual Electricity Cost by State Rate (1,181 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$214.00/yrHawaii$557.00/yrCalifornia$351.00/yrTexas$188.00/yrWashington$173.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $214/yr $2,145 $7,647
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $557/yr $5,572 $19,867
California 29.75 ¢/kWh ($0.2975) $351/yr $3,513 $12,528
Texas 15.91 ¢/kWh ($0.1591) $188/yr $1,879 $6,700
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $173/yr $1,728 $6,161
Estimated electricity spend (1,181 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any LG Series Triggered CPSC Recalls?

SaferProducts screening on 2026-11-23 returned zero recall matches for LG; confirm tank age separately using the rating-plate serial pattern. See Serial Number Lookup.

What Are 5 Direct Alternatives to LG APHWC502M?

Homeowners cross-shopping LG APHWC502M frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
GREE GRS-3.0Pd/TD50GANhA-D Hybrid/Electric Heat Pump 55 gal 80 gal 4.02 (-0.18) 1,234
VAUGHN THERMAL MP55FHPT Hybrid/Electric Heat Pump 55 gal 62 gal 3.3 (-0.90) 982
GE Profile PK50S10FNY01 Hybrid/Electric Heat Pump 50 gal 60 gal 4.2 (at parity) 773
Hubbell ME65HPT Hybrid/Electric Heat Pump 57 gal 70 gal 3.34 (-0.86) 974
GE Profile PH50S10BPY01 Hybrid/Electric Heat Pump 50 gal 77 gal 4.3 (+0.10) 1,154

Which Home Setups Are NOT a Fit for LG APHWC502M?

Comparing LG APHWC502M against GREE GRS-3.0Pd/TD50GANhA-D requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • LG APHWC502M needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting LG APHWC502M directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing LG APHWC502M Strong Fit — 4.2 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare GREE GRS-3.0Pd/TD50GANhA-D footprint.

Sizing, Efficiency & Recall Answers for LG APHWC502M

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does LG APHWC502M score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; LG APHWC502M logs 4.2 UEF (Pass: +1.90 / +82.6%) within the 706-unit Hybrid/Electric Heat Pump group.

What physical clearance dimensions apply when installing LG APHWC502M?

With a 47.6 in. height and 19.7 in. diameter, LG APHWC502M fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (19.7" d), plus 6–12 in. above for plumbing shutoffs.

What 240V circuit or IFGC fuel line capacity fits LG APHWC502M?

Powered via 240V at 24A max, LG APHWC502M requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

How do state electricity prices change annual costs for LG APHWC502M?

Annual electric spend for LG APHWC502M (1,181 kWh/yr) averages $214/yr nationwide (ranging from $173/yr in Washington hydro tiers up to $557/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

What homeowner setups should avoid choosing LG APHWC502M?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on LG APHWC502M.

Is LG APHWC502M sized adequately for a 2-to-4-person household?

ENERGY STAR certifies LG APHWC502M at 81 gal First Hour Rating (+9 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

Does LG have active CPSC SaferProducts notices affecting APHWC502M?

Zero CPSC recall alerts matched LG (2026-11-23 check). Keep your LG APHWC502M serial code handy to track standard 6-to-12-year OEM warranty coverage.

Which competing water heater matches LG APHWC502M (4.2 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for LG APHWC502M. Closest peer in Hybrid/Electric Heat Pump is GREE GRS-3.0Pd/TD50GANhA-D (4.02 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks