Skip to main content
ENERGY STAR water heater model · PD 3417703

Lochinvar HPPA065KD 2** Water Heater Specifications (3.84 UEF)

With PD 3417703 certification, Lochinvar HPPA065KD 2** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.84 UEF rating across its 68-gallon nominal tank, 83 gal First Hour Rating, standing #221 of 706 across 706 peers with Pass: +1.34 / +53.6% for May 6, 2029. Rated annual electricity draw of 1,292 kWh/yr equates to roughly $235/yr ($2,346 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith CAHP-66 2** (3.84 UEF).

Uniform Energy Factor
3.84 UEF
Cohort UEF Rank
#221 of 706 (top 32.4%)
First Hour Rating
83 gal
Storage Volume
68 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.34 / +53.6%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Lochinvar HPPA065KD 2** at 3.84 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Lochinvar HPPA065KD 2**: 3.84
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Lochinvar HPPA065KD 2** relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places Lochinvar HPPA065KD 2** at 3.84 UEF (#221 of 706; +0.14 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: Lochinvar HPPA065KD 2** stands +1.34 UEF (+53.6%) relative to 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,292 kWh/yr for Lochinvar HPPA065KD 2** runs ~$235/yr vs. ~$979/yr for a 0.92 UEF electric tank.

State electric sensitivity for Lochinvar HPPA065KD 2**: 10-year operating spend spans $1,890 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,096 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, A. O. Smith CAHP-66 2** (3.84 UEF, at parity) and American HPA10266H045DV 2** (3.84 UEF, at parity) bracket Lochinvar HPPA065KD 2**.

Which Specs Set Lochinvar HPPA065KD 2** Apart From Cohort Averages?

Ranked #221 of 706 (top 32.4%) inside the 706-model Hybrid/Electric Heat Pump cohort, Lochinvar HPPA065KD 2** is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandLochinvar65 certified listingsENERGY STAR PD 3417703
Model NumberHPPA065KD 2**Draw pattern: High-UsageHPPA065KD 2**
Uniform Energy Factor (UEF)3.84+0.14 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)83 gal+11 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,292 kWh/yr+220 kWh/yr vs. 1,072 kWh/yr medianEst. $235/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency435%+6.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)61" H x 23" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 22 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2025-12-12Certified 2025-12-12Markets: United States

How Do Regional kWh Prices Impact HPPA065KD 2** Over 10 Years?

Using EIA Table 5.6.A benchmarks, Lochinvar HPPA065KD 2**'s 1,292 kWh/yr draw translates to roughly $235/yr on typical US residential bills.

Estimated Annual Electricity Cost by State Rate (1,292 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$235.00/yrHawaii$610.00/yrCalifornia$384.00/yrTexas$206.00/yrWashington$189.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $235/yr $2,346 $7,447
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $610/yr $6,096 $19,349
California 29.75 ¢/kWh ($0.2975) $384/yr $3,844 $12,200
Texas 15.91 ¢/kWh ($0.1591) $206/yr $2,056 $6,525
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $189/yr $1,890 $6,000
Estimated electricity spend (1,292 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should Lochinvar Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC SaferProducts snapshot includes 1 filing tied to Lochinvar; verify whether your HPPA065KD 2** production run falls inside affected ranges. See Serial Number Lookup.

1 Brand Recall Notice Found in CPSC Feed — Verify Serial & Model Range
  • Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)

How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith CAHP-66 2** Hybrid/Electric Heat Pump 68 gal 83 gal 3.84 (at parity) 1,292
American HPA10266H045DV 2** Hybrid/Electric Heat Pump 68 gal 83 gal 3.84 (at parity) 1,292
RELIANCE WATER HEATERS 10-66-DHPTA 2** Hybrid/Electric Heat Pump 68 gal 83 gal 3.84 (at parity) 1,292
State CSHP-66 2** Hybrid/Electric Heat Pump 68 gal 83 gal 3.84 (at parity) 1,292
A. O. Smith HPA10-66H45DV 2** Hybrid/Electric Heat Pump 68 gal 83 gal 3.84 (at parity) 1,292

What Are the Limitations of Lochinvar HPPA065KD 2** and Who Should Not Install It?

Before ordering Lochinvar HPPA065KD 2** (Hybrid/Electric Heat Pump, 3.84 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

Key Limitations & Exclusions

  • Lochinvar HPPA065KD 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Lochinvar HPPA065KD 2** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Lochinvar HPPA065KD 2** Strong Fit — 3.84 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith CAHP-66 2** footprint.

Frequently Asked Technical Questions: Lochinvar HPPA065KD 2**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does Lochinvar HPPA065KD 2** pass the May 6, 2029 federal DOE efficiency rule?

Lochinvar HPPA065KD 2** carries a verified 3.84 UEF rating (Pass: +1.34 / +53.6%), ranking #221 of 706 (top 32.4%) across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

What doorway width and ceiling height does Lochinvar HPPA065KD 2** need?

Lochinvar HPPA065KD 2** stands 61 in. high with a 23 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

What gas pipe size or electrical breaker does Lochinvar HPPA065KD 2** require?

Lochinvar HPPA065KD 2** uses a 240V branch circuit at 22A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

How much electricity or energy does Lochinvar HPPA065KD 2** cost per year to run?

Rated at 1,292 kWh/yr, Lochinvar HPPA065KD 2** costs about $235/yr ($2,350 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $189/yr in Washington hydro tiers up to $610/yr in Hawaii).

Who should NOT install Lochinvar HPPA065KD 2**, and what are its limits?

Lochinvar HPPA065KD 2** (3.84 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.

How many bathrooms or people can Lochinvar HPPA065KD 2** serve at peak demand?

Lochinvar HPPA065KD 2** achieves a 83 gal First Hour Rating (+11 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

Are there CPSC safety recalls or serial checks for Lochinvar HPPA065KD 2**?

CPSC SaferProducts records show 1 brand-level recall notice mentioning Lochinvar as of 2026-11-23, including #05274 (2005-09-16). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

What 2026 rebates apply to Lochinvar HPPA065KD 2**, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is A. O. Smith CAHP-66 2** (3.84 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)