Midea MAHW-50VN3B Water Heater Specifications (3.75 UEF)
Engineered as a Electric Hybrid/Electric Heat Pump unit, Midea MAHW-50VN3B achieves a certified 3.75 UEF rating across its 46-gallon nominal tank, 71 gal First Hour Rating and ranks #297 of 706 in its 706-model cohort (PD 4682187), recording Pass: +1.45 / +63.0% under 2029 DOE rules. Rated annual electricity draw of 861 kWh/yr equates to roughly $156/yr ($1,564 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Rinnai REHP50CW (3.75 UEF).
- Uniform Energy Factor
- 3.75 UEF
- Cohort UEF Rank
- #297 of 706
- First Hour Rating
- 71 gal
- Storage Volume
- 46 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.45 / +63.0%

Within the 706-unit Hybrid/Electric Heat Pump cohort, Midea MAHW-50VN3B logs 3.75 UEF and ranks #297 of 706.
Against 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF), Midea MAHW-50VN3B holds a +1.45 UEF (+63.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 861 kWh/yr for Midea MAHW-50VN3B runs ~$156/yr vs. ~$637/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).
State electric sensitivity for Midea MAHW-50VN3B: 10-year operating spend spans $1,260 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,062 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Cross-shopping Midea MAHW-50VN3B (3.75 UEF)? Check Rinnai REHP50CW (3.75 UEF, at parity) and A. O. Smith HPS10-50H45DV 2** (3.8 UEF, delta +0.05).
Which Specs Set Midea MAHW-50VN3B Apart From Cohort Averages?
Ranked #297 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, Midea MAHW-50VN3B is evaluated row by row below against category medians.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Midea | 49 certified listings | ENERGY STAR PD 4682187 |
| Model Number | MAHW-50VN3B | Draw pattern: Medium-Usage | MAHW-50VN3B |
| Uniform Energy Factor (UEF) | 3.75 | +0.05 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 71 gal | -1 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 861 kWh/yr | -211 kWh/yr vs. 1,072 kWh/yr median | Est. $156/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 420% | -9.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 46.6" H x 18.3" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 24 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Sound Pressure Level | 49 dBA | quieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA median | Indoor placement check |
| Certification Date | 2026-07-31 | Certified 2026-07-31 | Markets: United States, Canada |
How Do Regional kWh Prices Impact MAHW-50VN3B Over 10 Years?
Using EIA Table 5.6.A benchmarks, Midea MAHW-50VN3B's 861 kWh/yr draw translates to roughly $156/yr on typical US residential bills.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $156/yr | $1,564 | $4,811 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $406/yr | $4,062 | $12,498 |
| California | 29.75 ¢/kWh ($0.2975) | $256/yr | $2,561 | $7,881 |
| Texas | 15.91 ¢/kWh ($0.1591) | $137/yr | $1,370 | $4,215 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $126/yr | $1,260 | $3,875 |
What Should Midea Owners Check in CPSC Recall Logs?
The 2026-11-23 CPSC recall sweep recorded zero brand matches for Midea; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.
How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?
Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Rinnai REHP50CW | Hybrid/Electric Heat Pump | 46 gal | 71 gal | 3.75 (at parity) | 861 |
| A. O. Smith HPS10-50H45DV 2** | Hybrid/Electric Heat Pump | 46 gal | 65 gal | 3.8 (+0.05) | 831 |
| American HPS10250H045DV 2** | Hybrid/Electric Heat Pump | 46 gal | 65 gal | 3.8 (+0.05) | 831 |
| Lochinvar HPSA050KD 2** | Hybrid/Electric Heat Pump | 46 gal | 65 gal | 3.8 (+0.05) | 831 |
| Rinnai REHP50W | Hybrid/Electric Heat Pump | 46 gal | 71 gal | 3.75 (at parity) | 861 |
When Should Homeowners Skip Midea MAHW-50VN3B (Hybrid/Electric Heat Pump)?
Check Midea MAHW-50VN3B's mechanical constraints—including utility space, Electric capacity, and Pass: +1.45 / +63.0% status—against typical residential installations.
Key Limitations & Exclusions
- Midea MAHW-50VN3B needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Midea MAHW-50VN3B directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Frequently Asked Technical Questions: Midea MAHW-50VN3B
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Will Midea MAHW-50VN3B stay compliant after the May 6, 2029 DOE standard takes effect?
Tested at 3.75 UEF, Midea MAHW-50VN3B shows Pass: +1.45 / +63.0% relative to May 6, 2029 federal DOE limits while placing #297 of 706 among 706 Hybrid/Electric Heat Pump peers like Rinnai REHP50CW.
Will Midea MAHW-50VN3B fit through a standard utility door and 72-inch basement ceiling?
Measuring 46.6 in. tall by 18.3 in. diameter, Midea MAHW-50VN3B notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.3" d). Reserve space above the jacket for T&P piping and anode removal.
Do existing utility hookups support Midea MAHW-50VN3B during replacement?
Electrical specs for Midea MAHW-50VN3B call for 240V at 24A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.
What is the estimated 10-year operating spend for Midea MAHW-50VN3B?
At 18.16 cents/kWh national residential pricing, Midea MAHW-50VN3B's 861 kWh/yr draw equals roughly $156 annually or $1,560 across a 10-year horizon (ranging from $126/yr in Washington hydro tiers up to $406/yr in Hawaii).
When is Midea MAHW-50VN3B a poor fit for a residential replacement?
Avoid placing Midea MAHW-50VN3B directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.
What First Hour Rating or flow capacity does Midea MAHW-50VN3B deliver?
With 71 gal FHR (-1 gal vs. 72 gal median), Midea MAHW-50VN3B fits larger 3–5 person homes cleanly.
How do you verify manufacturing age and recall status on Midea MAHW-50VN3B?
Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Midea; verify exact manufacturing week for Midea MAHW-50VN3B using the Serial Number Lookup tool.
Does Midea MAHW-50VN3B qualify for DOE HEAR incentives after 25C expired?
After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Midea MAHW-50VN3B. Closest peer in Hybrid/Electric Heat Pump is Rinnai REHP50CW (3.75 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)