Skip to main content
ENERGY STAR water heater model · PD 4682187

Midea MAHW-50VN3B Water Heater Specifications (3.75 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, Midea MAHW-50VN3B achieves a certified 3.75 UEF rating across its 46-gallon nominal tank, 71 gal First Hour Rating and ranks #297 of 706 in its 706-model cohort (PD 4682187), recording Pass: +1.45 / +63.0% under 2029 DOE rules. Rated annual electricity draw of 861 kWh/yr equates to roughly $156/yr ($1,564 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Rinnai REHP50CW (3.75 UEF).

Uniform Energy Factor
3.75 UEF
Cohort UEF Rank
#297 of 706
First Hour Rating
71 gal
Storage Volume
46 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.45 / +63.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Midea MAHW-50VN3B at 3.75 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Midea MAHW-50VN3B: 3.75
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Midea MAHW-50VN3B relative to the cohort median.
Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, Midea MAHW-50VN3B logs 3.75 UEF and ranks #297 of 706.

Against 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF), Midea MAHW-50VN3B holds a +1.45 UEF (+63.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 861 kWh/yr for Midea MAHW-50VN3B runs ~$156/yr vs. ~$637/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).

State electric sensitivity for Midea MAHW-50VN3B: 10-year operating spend spans $1,260 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,062 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping Midea MAHW-50VN3B (3.75 UEF)? Check Rinnai REHP50CW (3.75 UEF, at parity) and A. O. Smith HPS10-50H45DV 2** (3.8 UEF, delta +0.05).

Which Specs Set Midea MAHW-50VN3B Apart From Cohort Averages?

Ranked #297 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, Midea MAHW-50VN3B is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandMidea49 certified listingsENERGY STAR PD 4682187
Model NumberMAHW-50VN3BDraw pattern: Medium-UsageMAHW-50VN3B
Uniform Energy Factor (UEF)3.75+0.05 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)71 gal-1 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use861 kWh/yr-211 kWh/yr vs. 1,072 kWh/yr medianEst. $156/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency420%-9.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)46.6" H x 18.3" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 24 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Sound Pressure Level49 dBAquieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA medianIndoor placement check
Certification Date2026-07-31Certified 2026-07-31Markets: United States, Canada

How Do Regional kWh Prices Impact MAHW-50VN3B Over 10 Years?

Using EIA Table 5.6.A benchmarks, Midea MAHW-50VN3B's 861 kWh/yr draw translates to roughly $156/yr on typical US residential bills.

Estimated Annual Electricity Cost by State Rate (861 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$156.00/yrHawaii$406.00/yrCalifornia$256.00/yrTexas$137.00/yrWashington$126.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $156/yr $1,564 $4,811
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $406/yr $4,062 $12,498
California 29.75 ¢/kWh ($0.2975) $256/yr $2,561 $7,881
Texas 15.91 ¢/kWh ($0.1591) $137/yr $1,370 $4,215
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $126/yr $1,260 $3,875
Estimated electricity spend (861 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should Midea Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC recall sweep recorded zero brand matches for Midea; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.

How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Rinnai REHP50CW Hybrid/Electric Heat Pump 46 gal 71 gal 3.75 (at parity) 861
A. O. Smith HPS10-50H45DV 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.8 (+0.05) 831
American HPS10250H045DV 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.8 (+0.05) 831
Lochinvar HPSA050KD 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.8 (+0.05) 831
Rinnai REHP50W Hybrid/Electric Heat Pump 46 gal 71 gal 3.75 (at parity) 861

When Should Homeowners Skip Midea MAHW-50VN3B (Hybrid/Electric Heat Pump)?

Check Midea MAHW-50VN3B's mechanical constraints—including utility space, Electric capacity, and Pass: +1.45 / +63.0% status—against typical residential installations.

Key Limitations & Exclusions

  • Midea MAHW-50VN3B needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Midea MAHW-50VN3B directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Midea MAHW-50VN3B Strong Fit — 3.75 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Rinnai REHP50CW footprint.

Frequently Asked Technical Questions: Midea MAHW-50VN3B

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will Midea MAHW-50VN3B stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.75 UEF, Midea MAHW-50VN3B shows Pass: +1.45 / +63.0% relative to May 6, 2029 federal DOE limits while placing #297 of 706 among 706 Hybrid/Electric Heat Pump peers like Rinnai REHP50CW.

Will Midea MAHW-50VN3B fit through a standard utility door and 72-inch basement ceiling?

Measuring 46.6 in. tall by 18.3 in. diameter, Midea MAHW-50VN3B notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.3" d). Reserve space above the jacket for T&P piping and anode removal.

Do existing utility hookups support Midea MAHW-50VN3B during replacement?

Electrical specs for Midea MAHW-50VN3B call for 240V at 24A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

What is the estimated 10-year operating spend for Midea MAHW-50VN3B?

At 18.16 cents/kWh national residential pricing, Midea MAHW-50VN3B's 861 kWh/yr draw equals roughly $156 annually or $1,560 across a 10-year horizon (ranging from $126/yr in Washington hydro tiers up to $406/yr in Hawaii).

When is Midea MAHW-50VN3B a poor fit for a residential replacement?

Avoid placing Midea MAHW-50VN3B directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

What First Hour Rating or flow capacity does Midea MAHW-50VN3B deliver?

With 71 gal FHR (-1 gal vs. 72 gal median), Midea MAHW-50VN3B fits larger 3–5 person homes cleanly.

How do you verify manufacturing age and recall status on Midea MAHW-50VN3B?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Midea; verify exact manufacturing week for Midea MAHW-50VN3B using the Serial Number Lookup tool.

Does Midea MAHW-50VN3B qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Midea MAHW-50VN3B. Closest peer in Hybrid/Electric Heat Pump is Rinnai REHP50CW (3.75 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks