Skip to main content
ENERGY STAR water heater model · PD 4654274

Midea US3-RSJ-15/190RDVN3-L4 Water Heater Specifications (3.75 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, Midea US3-RSJ-15/190RDVN3-L4 (Electric) achieves a certified 3.75 UEF rating across its 46-gallon nominal tank, 71 gal First Hour Rating (rank #297 of 706, PD 4654274) and verifies as Pass: +1.45 / +63.0% for 2029 DOE floors. Rated annual electricity draw of 861 kWh/yr equates to roughly $156/yr ($1,564 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Rinnai REHP50CW (3.75 UEF).

Uniform Energy Factor
3.75 UEF
Cohort UEF Rank
#297 of 706
First Hour Rating
71 gal
Storage Volume
46 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.45 / +63.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Midea US3-RSJ-15/190RDVN3-L4 at 3.75 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Midea US3-RSJ-15/190RDVN3-L4: 3.75
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Midea US3-RSJ-15/190RDVN3-L4 relative to the cohort median.
Efficiency comparison & rule summary

Midea US3-RSJ-15/190RDVN3-L4 records 3.75 UEF efficiency, putting it #297 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: Midea US3-RSJ-15/190RDVN3-L4 exceeds 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.45 UEF (+63.0%). At EIA August 2026 national rates (18.16 cents/kWh), 861 kWh/yr for Midea US3-RSJ-15/190RDVN3-L4 runs ~$156/yr vs. ~$637/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).

State electric sensitivity for Midea US3-RSJ-15/190RDVN3-L4: 10-year operating spend spans $1,260 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,062 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside Midea US3-RSJ-15/190RDVN3-L4 (3.75 UEF) are Rinnai REHP50CW (3.75 UEF, at parity) and A. O. Smith HPS10-50H45DV 2** (3.8 UEF, delta +0.05).

How Do Midea US3-RSJ-15/190RDVN3-L4 Specs Compare to Hybrid/Electric Heat Pump Medians?

Midea US3-RSJ-15/190RDVN3-L4 places #297 of 706 across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandMidea49 certified listingsENERGY STAR PD 4654274
Model NumberUS3-RSJ-15/190RDVN3-L4Draw pattern: Medium-UsageUS3-RSJ-15/190RDVN3-L4
Uniform Energy Factor (UEF)3.75+0.05 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)71 gal-1 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use861 kWh/yr-211 kWh/yr vs. 1,072 kWh/yr medianEst. $156/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency420%-9.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)46.6" H x 18.3" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 24 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Sound Pressure Level49 dBAquieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA medianIndoor placement check
Certification Date2026-06-17Certified 2026-06-17Markets: United States, Canada

What Does US3-RSJ-15/190RDVN3-L4 Cost to Operate Across State Electricity Rates?

At 861 kWh/yr, Midea US3-RSJ-15/190RDVN3-L4 runs roughly $156/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Estimated Annual Electricity Cost by State Rate (861 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$156.00/yrHawaii$406.00/yrCalifornia$256.00/yrTexas$137.00/yrWashington$126.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $156/yr $1,564 $4,811
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $406/yr $4,062 $12,498
California 29.75 ¢/kWh ($0.2975) $256/yr $2,561 $7,881
Texas 15.91 ¢/kWh ($0.1591) $137/yr $1,370 $4,215
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $126/yr $1,260 $3,875
Estimated electricity spend (861 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for Midea Water Heaters?

Zero active CPSC recalls matched Midea in our 2026-11-23 SaferProducts sweep; verify your individual tank date code via our lookup tool. See Serial Number Lookup.

Which Certified Water Heaters Match US3-RSJ-15/190RDVN3-L4 Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to Midea US3-RSJ-15/190RDVN3-L4 by storage capacity and 3.75 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Rinnai REHP50CW Hybrid/Electric Heat Pump 46 gal 71 gal 3.75 (at parity) 861
A. O. Smith HPS10-50H45DV 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.8 (+0.05) 831
American HPS10250H045DV 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.8 (+0.05) 831
Lochinvar HPSA050KD 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.8 (+0.05) 831
Rinnai REHP50W Hybrid/Electric Heat Pump 46 gal 71 gal 3.75 (at parity) 861

Which Home Setups Are NOT a Fit for Midea US3-RSJ-15/190RDVN3-L4?

Comparing Midea US3-RSJ-15/190RDVN3-L4 against Rinnai REHP50CW requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • Midea US3-RSJ-15/190RDVN3-L4 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Midea US3-RSJ-15/190RDVN3-L4 directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Midea US3-RSJ-15/190RDVN3-L4 Strong Fit — 3.75 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Rinnai REHP50CW footprint.

What Are the Key Questions About Midea US3-RSJ-15/190RDVN3-L4?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Midea US3-RSJ-15/190RDVN3-L4 score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Midea US3-RSJ-15/190RDVN3-L4 logs 3.75 UEF (Pass: +1.45 / +63.0%) within the 706-unit Hybrid/Electric Heat Pump group.

What physical clearance dimensions apply when installing Midea US3-RSJ-15/190RDVN3-L4?

With a 46.6 in. height and 18.3 in. diameter, Midea US3-RSJ-15/190RDVN3-L4 fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.3" d), plus 6–12 in. above for plumbing shutoffs.

What 240V circuit or IFGC fuel line capacity fits Midea US3-RSJ-15/190RDVN3-L4?

Powered via 240V at 24A max, Midea US3-RSJ-15/190RDVN3-L4 requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

How do state electricity prices change annual costs for Midea US3-RSJ-15/190RDVN3-L4?

Annual electric spend for Midea US3-RSJ-15/190RDVN3-L4 (861 kWh/yr) averages $156/yr nationwide (ranging from $126/yr in Washington hydro tiers up to $406/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

What homeowner setups should avoid choosing Midea US3-RSJ-15/190RDVN3-L4?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Midea US3-RSJ-15/190RDVN3-L4.

Is Midea US3-RSJ-15/190RDVN3-L4 sized adequately for a 2-to-4-person household?

ENERGY STAR certifies Midea US3-RSJ-15/190RDVN3-L4 at 71 gal First Hour Rating (-1 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

Does Midea have active CPSC SaferProducts notices affecting US3-RSJ-15/190RDVN3-L4?

Zero CPSC recall alerts matched Midea (2026-11-23 check). Keep your Midea US3-RSJ-15/190RDVN3-L4 serial code handy to track standard 6-to-12-year OEM warranty coverage.

Which competing water heater matches Midea US3-RSJ-15/190RDVN3-L4 (3.75 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Midea US3-RSJ-15/190RDVN3-L4. Closest peer in Hybrid/Electric Heat Pump is Rinnai REHP50CW (3.75 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks