NOVAIR TCL-65GL-R134A Water Heater Specifications (3.9 UEF)
With PD 4518068 certification, NOVAIR TCL-65GL-R134A (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.9 UEF rating across its 60-gallon nominal tank, 80 gal First Hour Rating, standing #144 of 706 across 706 peers with Pass: +1.40 / +56.0% for May 6, 2029. Rated annual electricity draw of 1,240 kWh/yr equates to roughly $225/yr ($2,252 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Bosch TR7000T-65CA (3.9 UEF).
- Uniform Energy Factor
- 3.9 UEF
- Cohort UEF Rank
- #144 of 706 (top 22.9%)
- First Hour Rating
- 80 gal
- Storage Volume
- 60 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.40 / +56.0%

ENERGY STAR certification places NOVAIR TCL-65GL-R134A at 3.9 UEF (#144 of 706; +0.20 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.
May 6, 2029 readiness: NOVAIR TCL-65GL-R134A stands +1.40 UEF (+56.0%) relative to 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,240 kWh/yr for NOVAIR TCL-65GL-R134A runs ~$225/yr vs. ~$955/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).
State electric sensitivity for NOVAIR TCL-65GL-R134A: 10-year operating spend spans $1,814 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,850 in Hawaii (Highest EIA State) (47.18 cents/kWh).
In the Hybrid/Electric Heat Pump tier, Bosch TR7000T-65CA (3.9 UEF, at parity) and Custom Comfort CCOHPWH65A (3.9 UEF, at parity) bracket NOVAIR TCL-65GL-R134A.
How Do NOVAIR TCL-65GL-R134A Specs Compare to Hybrid/Electric Heat Pump Medians?
NOVAIR TCL-65GL-R134A places #144 of 706 (top 22.9%) across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | NOVAIR | 3 certified listings | ENERGY STAR PD 4518068 |
| Model Number | TCL-65GL-R134A | Draw pattern: High-Usage | TCL-65GL-R134A |
| Uniform Energy Factor (UEF) | 3.9 | +0.20 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 80 gal | +8 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,240 kWh/yr | +168 kWh/yr vs. 1,072 kWh/yr median | Est. $225/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 450% | +21.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 45.5" H x 21.8" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 24 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Sound Pressure Level | 49 dBA | quieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA median | Indoor placement check |
| Certification Date | 2025-12-12 | Certified 2025-12-12 | Markets: United States, Canada |
What Does TCL-65GL-R134A Cost to Operate Across State Electricity Rates?
At 1,240 kWh/yr, NOVAIR TCL-65GL-R134A runs roughly $225/yr on the EIA national average tier under August 2026 Table 5.6.A rates.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $225/yr | $2,252 | $7,295 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $585/yr | $5,850 | $18,952 |
| California | 29.75 ¢/kWh ($0.2975) | $369/yr | $3,689 | $11,951 |
| Texas | 15.91 ¢/kWh ($0.1591) | $197/yr | $1,973 | $6,391 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $181/yr | $1,814 | $5,877 |
Are There Active CPSC Safety Recalls for NOVAIR Water Heaters?
Zero active CPSC recalls matched NOVAIR in our 2026-11-23 SaferProducts sweep; verify your individual tank date code via our lookup tool. See Serial Number Lookup.
Which Certified Water Heaters Match TCL-65GL-R134A Most Closely?
These 5 competing Hybrid/Electric Heat Pump units sit nearest to NOVAIR TCL-65GL-R134A by storage capacity and 3.9 UEF rating.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Bosch TR7000T-65CA | Hybrid/Electric Heat Pump | 60 gal | 80 gal | 3.9 (at parity) | 1,240 |
| Custom Comfort CCOHPWH65A | Hybrid/Electric Heat Pump | 60 gal | 80 gal | 3.9 (at parity) | 1,240 |
| Eco-Logical ECO-65HPM1A | Hybrid/Electric Heat Pump | 60 gal | 80 gal | 3.9 (at parity) | 1,240 |
| Kepler AZMCHW-65VN3A | Hybrid/Electric Heat Pump | 60 gal | 80 gal | 3.9 (at parity) | 1,240 |
| Bosch TR7000T-65US | Hybrid/Electric Heat Pump | 60 gal | 80 gal | 3.9 (at parity) | 1,240 |
Who Is NOVAIR TCL-65GL-R134A Best For — and When Should You Pick Bosch TR7000T-65CA?
Evaluate whether NOVAIR TCL-65GL-R134A's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.
Key Limitations & Exclusions
- NOVAIR TCL-65GL-R134A needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting NOVAIR TCL-65GL-R134A directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
What Are the Key Questions About NOVAIR TCL-65GL-R134A?
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does NOVAIR TCL-65GL-R134A (3.9 UEF) compare to 2029 federal DOE floors?
Evaluated against May 6, 2029 10 CFR 430.32 thresholds, NOVAIR TCL-65GL-R134A records 3.9 UEF (Pass: +1.40 / +56.0%), placing #144 of 706 (top 22.9%) out of 706 certified Hybrid/Electric Heat Pump configurations.
Does NOVAIR TCL-65GL-R134A fit inside a tight hallway closet or low-headroom utility room?
NOVAIR TCL-65GL-R134A requires room for its 45.5 in. vertical shell and 21.8 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d)), plus service access for annual sediment draining.
What power supply or fuel line specs govern NOVAIR TCL-65GL-R134A?
For NOVAIR TCL-65GL-R134A, plan a 240V circuit at 24A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.
What annual utility bill should homeowners budget for NOVAIR TCL-65GL-R134A?
Using 1,240 kWh/yr, NOVAIR TCL-65GL-R134A generates an estimated $225/yr electric bill at 18.16 cents/kWh (ranging from $181/yr in Washington hydro tiers up to $585/yr in Hawaii)—use the custom rate slider above for your utility tariff.
What are the main drawbacks of NOVAIR TCL-65GL-R134A (3.9 UEF)?
NOVAIR TCL-65GL-R134A requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or Bosch TR7000T-65CA.
What hot-water delivery rating governs NOVAIR TCL-65GL-R134A?
Rated for 80 gal FHR (+8 gal vs. 72 gal median), NOVAIR TCL-65GL-R134A prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.
Where do homeowners screen NOVAIR TCL-65GL-R134A for recalls and tank age?
Verified clean against 2026-11-23 CPSC recall feeds for NOVAIR; use our browser-only serial decoder to inspect NOVAIR TCL-65GL-R134A's age and warranty window.
What alternative models sit closest to NOVAIR TCL-65GL-R134A in the Hybrid/Electric Heat Pump class?
Closest peer in Hybrid/Electric Heat Pump is Bosch TR7000T-65CA (3.9 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)