NOVAIR TCL-65GL-R134A Water Heater Specifications (3.9 UEF)

With PD 4518068 certification, NOVAIR TCL-65GL-R134A (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.9 UEF rating across its 60-gallon nominal tank, 80 gal First Hour Rating, standing #144 of 706 across 706 peers with Pass: +1.40 / +56.0% for May 6, 2029. Rated annual electricity draw of 1,240 kWh/yr equates to roughly $225/yr ($2,252 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Bosch TR7000T-65CA (3.9 UEF).

Uniform Energy Factor
3.9 UEF
Cohort UEF Rank
#144 of 706 (top 22.9%)
First Hour Rating
80 gal
Storage Volume
60 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.40 / +56.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking NOVAIR TCL-65GL-R134A at 3.9 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50NOVAIR TCL-65GL-R134A: 3.90
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows NOVAIR TCL-65GL-R134A relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places NOVAIR TCL-65GL-R134A at 3.9 UEF (#144 of 706; +0.20 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: NOVAIR TCL-65GL-R134A stands +1.40 UEF (+56.0%) relative to 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,240 kWh/yr for NOVAIR TCL-65GL-R134A runs ~$225/yr vs. ~$955/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).

State electric sensitivity for NOVAIR TCL-65GL-R134A: 10-year operating spend spans $1,814 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,850 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, Bosch TR7000T-65CA (3.9 UEF, at parity) and Custom Comfort CCOHPWH65A (3.9 UEF, at parity) bracket NOVAIR TCL-65GL-R134A.

How Do NOVAIR TCL-65GL-R134A Specs Compare to Hybrid/Electric Heat Pump Medians?

NOVAIR TCL-65GL-R134A places #144 of 706 (top 22.9%) across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandNOVAIR3 certified listingsENERGY STAR PD 4518068
Model NumberTCL-65GL-R134ADraw pattern: High-UsageTCL-65GL-R134A
Uniform Energy Factor (UEF)3.9+0.20 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)80 gal+8 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,240 kWh/yr+168 kWh/yr vs. 1,072 kWh/yr medianEst. $225/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency450%+21.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)45.5" H x 21.8" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 24 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Sound Pressure Level49 dBAquieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA medianIndoor placement check
Certification Date2025-12-12Certified 2025-12-12Markets: United States, Canada

What Does TCL-65GL-R134A Cost to Operate Across State Electricity Rates?

At 1,240 kWh/yr, NOVAIR TCL-65GL-R134A runs roughly $225/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Estimated Annual Electricity Cost by State Rate (1,240 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$225.00/yrHawaii$585.00/yrCalifornia$369.00/yrTexas$197.00/yrWashington$181.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $225/yr $2,252 $7,295
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $585/yr $5,850 $18,952
California 29.75 ¢/kWh ($0.2975) $369/yr $3,689 $11,951
Texas 15.91 ¢/kWh ($0.1591) $197/yr $1,973 $6,391
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $181/yr $1,814 $5,877
Estimated electricity spend (1,240 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for NOVAIR Water Heaters?

Zero active CPSC recalls matched NOVAIR in our 2026-11-23 SaferProducts sweep; verify your individual tank date code via our lookup tool. See Serial Number Lookup.

Which Certified Water Heaters Match TCL-65GL-R134A Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to NOVAIR TCL-65GL-R134A by storage capacity and 3.9 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Bosch TR7000T-65CA Hybrid/Electric Heat Pump 60 gal 80 gal 3.9 (at parity) 1,240
Custom Comfort CCOHPWH65A Hybrid/Electric Heat Pump 60 gal 80 gal 3.9 (at parity) 1,240
Eco-Logical ECO-65HPM1A Hybrid/Electric Heat Pump 60 gal 80 gal 3.9 (at parity) 1,240
Kepler AZMCHW-65VN3A Hybrid/Electric Heat Pump 60 gal 80 gal 3.9 (at parity) 1,240
Bosch TR7000T-65US Hybrid/Electric Heat Pump 60 gal 80 gal 3.9 (at parity) 1,240

Who Is NOVAIR TCL-65GL-R134A Best For — and When Should You Pick Bosch TR7000T-65CA?

Evaluate whether NOVAIR TCL-65GL-R134A's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

Key Limitations & Exclusions

  • NOVAIR TCL-65GL-R134A needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting NOVAIR TCL-65GL-R134A directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing NOVAIR TCL-65GL-R134A Strong Fit — 3.9 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Bosch TR7000T-65CA footprint.

What Are the Key Questions About NOVAIR TCL-65GL-R134A?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does NOVAIR TCL-65GL-R134A (3.9 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, NOVAIR TCL-65GL-R134A records 3.9 UEF (Pass: +1.40 / +56.0%), placing #144 of 706 (top 22.9%) out of 706 certified Hybrid/Electric Heat Pump configurations.

Does NOVAIR TCL-65GL-R134A fit inside a tight hallway closet or low-headroom utility room?

NOVAIR TCL-65GL-R134A requires room for its 45.5 in. vertical shell and 21.8 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d)), plus service access for annual sediment draining.

What power supply or fuel line specs govern NOVAIR TCL-65GL-R134A?

For NOVAIR TCL-65GL-R134A, plan a 240V circuit at 24A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.

What annual utility bill should homeowners budget for NOVAIR TCL-65GL-R134A?

Using 1,240 kWh/yr, NOVAIR TCL-65GL-R134A generates an estimated $225/yr electric bill at 18.16 cents/kWh (ranging from $181/yr in Washington hydro tiers up to $585/yr in Hawaii)—use the custom rate slider above for your utility tariff.

What are the main drawbacks of NOVAIR TCL-65GL-R134A (3.9 UEF)?

NOVAIR TCL-65GL-R134A requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or Bosch TR7000T-65CA.

What hot-water delivery rating governs NOVAIR TCL-65GL-R134A?

Rated for 80 gal FHR (+8 gal vs. 72 gal median), NOVAIR TCL-65GL-R134A prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

Where do homeowners screen NOVAIR TCL-65GL-R134A for recalls and tank age?

Verified clean against 2026-11-23 CPSC recall feeds for NOVAIR; use our browser-only serial decoder to inspect NOVAIR TCL-65GL-R134A's age and warranty window.

What alternative models sit closest to NOVAIR TCL-65GL-R134A in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is Bosch TR7000T-65CA (3.9 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks