Skip to main content
ENERGY STAR water heater model · PD 4623614

Reclaim Energy MP120F-RC Water Heater Specifications (3.75 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, Reclaim Energy MP120F-RC (Electric) achieves a certified 3.75 UEF rating across its 119-gallon nominal tank, 121 gal First Hour Rating (rank #297 of 706, PD 4623614) and verifies as Pass: +1.25 / +50.0% for 2029 DOE floors. Rated annual electricity draw of 1,296 kWh/yr equates to roughly $235/yr ($2,354 over 10 years) at 18.16 cents/kWh. Closest certified alternative is VAUGHN THERMAL MP120F-RC (3.75 UEF).

Uniform Energy Factor
3.75 UEF
Cohort UEF Rank
#297 of 706
First Hour Rating
121 gal
Storage Volume
119 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.25 / +50.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Reclaim Energy MP120F-RC at 3.75 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Reclaim Energy MP120F-RC: 3.75
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Reclaim Energy MP120F-RC relative to the cohort median.
Efficiency comparison & rule summary

Reclaim Energy MP120F-RC records 3.75 UEF efficiency, putting it #297 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: Reclaim Energy MP120F-RC exceeds 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.25 UEF (+50.0%). At EIA August 2026 national rates (18.16 cents/kWh), 1,296 kWh/yr for Reclaim Energy MP120F-RC runs ~$235/yr vs. ~$959/yr for a 0.92 UEF electric tank. Acoustic output is 37 dBA (quieter than 93.3% of Hybrid/Electric Heat Pump models).

State electric sensitivity for Reclaim Energy MP120F-RC: 10-year operating spend spans $1,896 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,115 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside Reclaim Energy MP120F-RC (3.75 UEF) are VAUGHN THERMAL MP120F-RC (3.75 UEF, at parity) and SANCO2 GS5-45HPC-D HP + ECO-119GLBK (3.72 UEF, delta -0.03).

How Complete Are the Certified Metrics for Reclaim Energy MP120F-RC?

Standing at #297 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, Reclaim Energy MP120F-RC brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandReclaim Energy2 certified listingsENERGY STAR PD 4623614
Model NumberMP120F-RCDraw pattern: High-UsageMP120F-RC
Uniform Energy Factor (UEF)3.75+0.05 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)121 gal+49 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,296 kWh/yr+224 kWh/yr vs. 1,072 kWh/yr medianEst. $235/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency412%-17.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)73" H x 30" DNeeds >72 in. overhead clearance; tight at 28 in. door (30" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 6 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-744 (CO₂) (GWP:1 | Lower GWP)Lower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Sound Pressure Level37 dBAtop 6.7% · quieter than 93.3% of Hybrid/Electric Heat Pump models · -12 dBA vs. 49 dBA medianIndoor placement check
Certification Date2026-06-08Certified 2026-06-08Markets: United States, Canada

What Is the Projected Utility Bill for MP120F-RC by State?

At 1,296 kWh/yr, Reclaim Energy MP120F-RC averages about $235/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Estimated Annual Electricity Cost by State Rate (1,296 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$235.00/yrHawaii$611.00/yrCalifornia$386.00/yrTexas$206.00/yrWashington$190.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $235/yr $2,354 $7,240
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $611/yr $6,115 $18,811
California 29.75 ¢/kWh ($0.2975) $386/yr $3,856 $11,861
Texas 15.91 ¢/kWh ($0.1591) $206/yr $2,062 $6,343
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $190/yr $1,896 $5,833
Estimated electricity spend (1,296 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are Reclaim Energy Models Affected by Current CPSC Notices?

Zero brand-level CPSC hazard notices matched Reclaim Energy in our 2026-11-23 feed; decode your water heater's serial number below to confirm warranty status. See Serial Number Lookup.

Which 5 Models Offer Similar Output to MP120F-RC?

Ordered by minimal capacity and UEF spread relative to Reclaim Energy MP120F-RC, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
VAUGHN THERMAL MP120F-RC Hybrid/Electric Heat Pump 119 gal 121 gal 3.75 (at parity) 1,296
SANCO2 GS5-45HPC-D HP + ECO-119GLBK Hybrid/Electric Heat Pump 119 gal 134 gal 3.72 (-0.03) 1,333
Smart Solar SSG2-ES 120 Hybrid/Electric Heat Pump 120 gal 83 gal 2.85 (-0.90) 1,741
Hubbell ME120HPT Hybrid/Electric Heat Pump 109 gal 105 gal 3.38 (-0.37) 1,467
SANCO2 GS5-45HPC HP + ECO-119GLBK Hybrid/Electric Heat Pump 119 gal 134 gal 3.72 (-0.03) 1,333

What Installation Caveats Apply Before Buying Reclaim Energy MP120F-RC?

Even high-UEF units like Reclaim Energy MP120F-RC (3.75 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • Reclaim Energy MP120F-RC needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 37 dBA; avoid mounting Reclaim Energy MP120F-RC directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Reclaim Energy MP120F-RC Strong Fit — 3.75 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare VAUGHN THERMAL MP120F-RC footprint.

Practical Specs & Code Questions for Reclaim Energy MP120F-RC

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is Reclaim Energy MP120F-RC eligible for continued manufacture past May 6, 2029?

At 3.75 UEF, Reclaim Energy MP120F-RC achieves Pass: +1.25 / +50.0% for the 2029 DOE standard and stands #297 of 706 against VAUGHN THERMAL MP120F-RC and SANCO2 GS5-45HPC-D HP + ECO-119GLBK.

How tall and wide is Reclaim Energy MP120F-RC, and what service clearance is needed?

Physical dimensions for Reclaim Energy MP120F-RC are 73 in. height and 30 in. diameter (needs >72 in. overhead clearance; tight at 28 in. door (30" d)); verify stair turns and drain pan width before delivery.

Will Reclaim Energy MP120F-RC require upgrading household electrical panels or gas piping?

Reclaim Energy MP120F-RC draws 240V at 6A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

Is Reclaim Energy MP120F-RC economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $235/yr ($2,350 over 10 years) to power Reclaim Energy MP120F-RC at 1,296 kWh/yr under the 18.16 cents/kWh US average (ranging from $190/yr in Washington hydro tiers up to $611/yr in Hawaii).

Which installation bottlenecks limit Reclaim Energy MP120F-RC?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, Reclaim Energy MP120F-RC drops into resistance mode more often.

How does Reclaim Energy MP120F-RC handle simultaneous showers and laundry?

Delivering 121 gal in the first hour (+49 gal vs. 72 gal median), Reclaim Energy MP120F-RC combines 119 gal tank storage with rapid burner/element recovery.

How long is the warranty on Reclaim Energy MP120F-RC and how do you decode its serial?

CPSC records show 0 active plumbing recalls for Reclaim Energy as of 2026-11-23. Confirm install proof and serial manufacture year on Reclaim Energy MP120F-RC before calling service.

How do 2026 post-OBBBA rebates affect buying Reclaim Energy MP120F-RC?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is VAUGHN THERMAL MP120F-RC (3.75 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks