Skip to main content
ENERGY STAR water heater model · PD 4615174

VAUGHN THERMAL MP120F-RC Water Heater Specifications (3.75 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, VAUGHN THERMAL MP120F-RC (Electric) achieves a certified 3.75 UEF rating across its 119-gallon nominal tank, 121 gal First Hour Rating (rank #297 of 706, PD 4615174) and verifies as Pass: +1.25 / +50.0% for 2029 DOE floors. Rated annual electricity draw of 1,296 kWh/yr equates to roughly $235/yr ($2,354 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Reclaim Energy MP120F-RC (3.75 UEF).

Uniform Energy Factor
3.75 UEF
Cohort UEF Rank
#297 of 706
First Hour Rating
121 gal
Storage Volume
119 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.25 / +50.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking VAUGHN THERMAL MP120F-RC at 3.75 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50VAUGHN THERMAL MP120F-RC: 3.75
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows VAUGHN THERMAL MP120F-RC relative to the cohort median.
Efficiency comparison & rule summary

VAUGHN THERMAL MP120F-RC records 3.75 UEF efficiency, putting it #297 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: VAUGHN THERMAL MP120F-RC exceeds 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.25 UEF (+50.0%). At EIA August 2026 national rates (18.16 cents/kWh), 1,296 kWh/yr for VAUGHN THERMAL MP120F-RC runs ~$235/yr vs. ~$959/yr for a 0.92 UEF electric tank. Acoustic output is 37 dBA (quieter than 93.3% of Hybrid/Electric Heat Pump models).

State electric sensitivity for VAUGHN THERMAL MP120F-RC: 10-year operating spend spans $1,896 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,115 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside VAUGHN THERMAL MP120F-RC (3.75 UEF) are Reclaim Energy MP120F-RC (3.75 UEF, at parity) and SANCO2 GS5-45HPC-D HP + ECO-119GLBK (3.72 UEF, delta -0.03).

Which Specs Set VAUGHN THERMAL MP120F-RC Apart From Cohort Averages?

Ranked #297 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, VAUGHN THERMAL MP120F-RC is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandVAUGHN THERMAL13 certified listingsENERGY STAR PD 4615174
Model NumberMP120F-RCDraw pattern: High-UsageMP120F-RC
Uniform Energy Factor (UEF)3.75+0.05 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)121 gal+49 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,296 kWh/yr+224 kWh/yr vs. 1,072 kWh/yr medianEst. $235/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency412%-17.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)73" H x 30" DNeeds >72 in. overhead clearance; tight at 28 in. door (30" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 6 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-744 (CO₂) (GWP:1 | Lower GWP)Lower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Sound Pressure Level37 dBAtop 6.7% · quieter than 93.3% of Hybrid/Electric Heat Pump models · -12 dBA vs. 49 dBA medianIndoor placement check
Certification Date2026-05-21Certified 2026-05-21Markets: United States, Canada

How Do Regional kWh Prices Impact MP120F-RC Over 10 Years?

Using EIA Table 5.6.A benchmarks, VAUGHN THERMAL MP120F-RC's 1,296 kWh/yr draw translates to roughly $235/yr on typical US residential bills.

Estimated Annual Electricity Cost by State Rate (1,296 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$235.00/yrHawaii$611.00/yrCalifornia$386.00/yrTexas$206.00/yrWashington$190.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $235/yr $2,354 $7,240
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $611/yr $6,115 $18,811
California 29.75 ¢/kWh ($0.2975) $386/yr $3,856 $11,861
Texas 15.91 ¢/kWh ($0.1591) $206/yr $2,062 $6,343
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $190/yr $1,896 $5,833
Estimated electricity spend (1,296 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should VAUGHN THERMAL Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC recall sweep recorded zero brand matches for VAUGHN THERMAL; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.

How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Reclaim Energy MP120F-RC Hybrid/Electric Heat Pump 119 gal 121 gal 3.75 (at parity) 1,296
SANCO2 GS5-45HPC-D HP + ECO-119GLBK Hybrid/Electric Heat Pump 119 gal 134 gal 3.72 (-0.03) 1,333
Smart Solar SSG2-ES 120 Hybrid/Electric Heat Pump 120 gal 83 gal 2.85 (-0.90) 1,741
Hubbell ME120HPT Hybrid/Electric Heat Pump 109 gal 105 gal 3.38 (-0.37) 1,467
SANCO2 GS5-45HPC HP + ECO-119GLBK Hybrid/Electric Heat Pump 119 gal 134 gal 3.72 (-0.03) 1,333

What Installation Caveats Apply Before Buying VAUGHN THERMAL MP120F-RC?

Even high-UEF units like VAUGHN THERMAL MP120F-RC (3.75 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • VAUGHN THERMAL MP120F-RC needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 37 dBA; avoid mounting VAUGHN THERMAL MP120F-RC directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing VAUGHN THERMAL MP120F-RC Strong Fit — 3.75 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Reclaim Energy MP120F-RC footprint.

Frequently Asked Technical Questions: VAUGHN THERMAL MP120F-RC

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is VAUGHN THERMAL MP120F-RC eligible for continued manufacture past May 6, 2029?

At 3.75 UEF, VAUGHN THERMAL MP120F-RC achieves Pass: +1.25 / +50.0% for the 2029 DOE standard and stands #297 of 706 against Reclaim Energy MP120F-RC and SANCO2 GS5-45HPC-D HP + ECO-119GLBK.

How tall and wide is VAUGHN THERMAL MP120F-RC, and what service clearance is needed?

Physical dimensions for VAUGHN THERMAL MP120F-RC are 73 in. height and 30 in. diameter (needs >72 in. overhead clearance; tight at 28 in. door (30" d)); verify stair turns and drain pan width before delivery.

Will VAUGHN THERMAL MP120F-RC require upgrading household electrical panels or gas piping?

VAUGHN THERMAL MP120F-RC draws 240V at 6A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

Is VAUGHN THERMAL MP120F-RC economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $235/yr ($2,350 over 10 years) to power VAUGHN THERMAL MP120F-RC at 1,296 kWh/yr under the 18.16 cents/kWh US average (ranging from $190/yr in Washington hydro tiers up to $611/yr in Hawaii).

Which installation bottlenecks limit VAUGHN THERMAL MP120F-RC?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, VAUGHN THERMAL MP120F-RC drops into resistance mode more often.

How does VAUGHN THERMAL MP120F-RC handle simultaneous showers and laundry?

Delivering 121 gal in the first hour (+49 gal vs. 72 gal median), VAUGHN THERMAL MP120F-RC combines 119 gal tank storage with rapid burner/element recovery.

How long is the warranty on VAUGHN THERMAL MP120F-RC and how do you decode its serial?

CPSC records show 0 active plumbing recalls for VAUGHN THERMAL as of 2026-11-23. Confirm install proof and serial manufacture year on VAUGHN THERMAL MP120F-RC before calling service.

How do 2026 post-OBBBA rebates affect buying VAUGHN THERMAL MP120F-RC?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is Reclaim Energy MP120F-RC (3.75 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks