ENERGY STAR water heater model · PD 3624320

SANCO2 GS5-45HPC-D HP + ECO-119GLBK Water Heater Specifications (3.72 UEF)

The SANCO2 GS5-45HPC-D HP + ECO-119GLBK (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.72 UEF rating across its 119-gallon nominal tank, 134 gal First Hour Rating, ranking #345 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 3624320). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.22 / +48.8%. Rated annual electricity draw of 1,333 kWh/yr equates to roughly $242/yr ($2,421 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Reclaim Energy MP120F-RC (3.75 UEF).

Uniform Energy Factor
3.72 UEF
Cohort UEF Rank
#345 of 706
First Hour Rating
134 gal
Storage Volume
119 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.22 / +48.8%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking SANCO2 GS5-45HPC-D HP + ECO-119GLBK at 3.72 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50SANCO2 GS5-45HPC-D HP + ECO-119GLBK: 3.72
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows SANCO2 GS5-45HPC-D HP + ECO-119GLBK relative to the cohort median.
Efficiency comparison & rule summary

SANCO2 GS5-45HPC-D HP + ECO-119GLBK (3.72 UEF) ranks #345 of 706 Hybrid/Electric Heat Pump models — 2-way tie; more efficient than 51% of Hybrid/Electric Heat Pump models, +0.02 UEF above the 3.70 UEF median.

Federal 2029 margin for SANCO2 GS5-45HPC-D HP + ECO-119GLBK: +1.22 UEF (+48.8%) vs. 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,333 kWh/yr for SANCO2 GS5-45HPC-D HP + ECO-119GLBK runs ~$242/yr vs. ~$979/yr for a 0.92 UEF electric tank. Acoustic output is 37 dBA (quieter than 93.3% of Hybrid/Electric Heat Pump models).

State electric sensitivity for SANCO2 GS5-45HPC-D HP + ECO-119GLBK: 10-year operating spend spans $1,950 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,289 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: SANCO2 GS5-45HPC-D HP + ECO-119GLBK (3.72 UEF) compares closely with Reclaim Energy MP120F-RC (3.75 UEF, delta +0.03) and VAUGHN THERMAL MP120F-RC (3.75 UEF, delta +0.03).

Where Does SANCO2 GS5-45HPC-D HP + ECO-119GLBK Rank Against Peer Hybrid/Electric Heat Pump Units?

Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, SANCO2 GS5-45HPC-D HP + ECO-119GLBK holds #345 of 706; inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandSANCO26 certified listingsENERGY STAR PD 3624320
Model NumberGS5-45HPC-D HP + ECO-119GLBKDraw pattern: High-UsageGS5-45HPC-D HP + ECO-119GLBK
Uniform Energy Factor (UEF)3.72+0.02 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)134 gal+62 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,333 kWh/yr+261 kWh/yr vs. 1,072 kWh/yr medianEst. $242/yr @ $0.1816/kWh (EIA US Avg)
Electrical Circuit Requirements230 V / 7 A maxVerify rating plate electrical drawNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-744 (CO₂) (GWP:1 | Lower GWP)Lower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Sound Pressure Level37 dBAtop 6.7% · quieter than 93.3% of Hybrid/Electric Heat Pump models · -12 dBA vs. 49 dBA medianIndoor placement check
Certification Date2014-08-21Certified 2014-08-21Markets: United States, Canada

How Much Electricity Does GS5-45HPC-D HP + ECO-119GLBK Use in Different States?

Estimated at $242/yr nationally (1,333 kWh/yr), 10-year utility spending for SANCO2 GS5-45HPC-D HP + ECO-119GLBK shifts sharply between low-rate hydro and coastal grids.

Estimated Annual Electricity Cost by State Rate (1,333 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$242.00/yrHawaii$629.00/yrCalifornia$397.00/yrTexas$212.00/yrWashington$195.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $242/yr $2,421 $7,368
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $629/yr $6,289 $19,141
California 29.75 ¢/kWh ($0.2975) $397/yr $3,966 $12,070
Texas 15.91 ¢/kWh ($0.1591) $212/yr $2,121 $6,455
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $195/yr $1,950 $5,935
Estimated electricity spend (1,333 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Does CPSC Flag Any Safety Notices on SANCO2 Units?

No open CPSC recall alerts appeared for SANCO2 as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See Serial Number Lookup.

Which Competing Hybrid/Electric Heat Pump Models Compare Closest to GS5-45HPC-D HP + ECO-119GLBK?

Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to SANCO2 GS5-45HPC-D HP + ECO-119GLBK's gallon capacity and 3.72 UEF efficiency.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Reclaim Energy MP120F-RC Hybrid/Electric Heat Pump 119 gal 121 gal 3.75 (+0.03) 1,296
VAUGHN THERMAL MP120F-RC Hybrid/Electric Heat Pump 119 gal 121 gal 3.75 (+0.03) 1,296
Smart Solar SSG2-ES 120 Hybrid/Electric Heat Pump 120 gal 83 gal 2.85 (-0.87) 1,741
Hubbell ME120HPT Hybrid/Electric Heat Pump 109 gal 105 gal 3.38 (-0.34) 1,467
VAUGHN THERMAL MP120FHPT Hybrid/Electric Heat Pump 119 gal 115 gal 3.5 (-0.22) 1,418

What Installation Caveats Apply Before Buying SANCO2 GS5-45HPC-D HP + ECO-119GLBK?

Even high-UEF units like SANCO2 GS5-45HPC-D HP + ECO-119GLBK (3.72 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • SANCO2 GS5-45HPC-D HP + ECO-119GLBK needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 37 dBA; avoid mounting SANCO2 GS5-45HPC-D HP + ECO-119GLBK directly beside quiet bedrooms.
  • Requires condensate drain routing and 230V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing SANCO2 GS5-45HPC-D HP + ECO-119GLBK Strong Fit — 3.72 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Reclaim Energy MP120F-RC footprint.

Common Homeowner Questions for SANCO2 GS5-45HPC-D HP + ECO-119GLBK

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is SANCO2 GS5-45HPC-D HP + ECO-119GLBK eligible for continued manufacture past May 6, 2029?

At 3.72 UEF, SANCO2 GS5-45HPC-D HP + ECO-119GLBK achieves Pass: +1.22 / +48.8% for the 2029 DOE standard and stands #345 of 706 against Reclaim Energy MP120F-RC and VAUGHN THERMAL MP120F-RC.

How tall and wide is SANCO2 GS5-45HPC-D HP + ECO-119GLBK, and what service clearance is needed?

SANCO2 GS5-45HPC-D HP + ECO-119GLBK saves floor space via its hybrid/electric heat pump layout (wall-hung / compact envelope); inspect service-valve swing clearance below the bottom manifold.

Will SANCO2 GS5-45HPC-D HP + ECO-119GLBK require upgrading household electrical panels or gas piping?

SANCO2 GS5-45HPC-D HP + ECO-119GLBK draws 230V at 7A max (Verify rating plate electrical draw); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

Is SANCO2 GS5-45HPC-D HP + ECO-119GLBK economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $242/yr ($2,420 over 10 years) to power SANCO2 GS5-45HPC-D HP + ECO-119GLBK at 1,333 kWh/yr under the 18.16 cents/kWh US average (ranging from $195/yr in Washington hydro tiers up to $629/yr in Hawaii).

Which installation bottlenecks limit SANCO2 GS5-45HPC-D HP + ECO-119GLBK?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, SANCO2 GS5-45HPC-D HP + ECO-119GLBK drops into resistance mode more often.

How does SANCO2 GS5-45HPC-D HP + ECO-119GLBK handle simultaneous showers and laundry?

Delivering 134 gal in the first hour (+62 gal vs. 72 gal median), SANCO2 GS5-45HPC-D HP + ECO-119GLBK combines 119 gal tank storage with rapid burner/element recovery.

How long is the warranty on SANCO2 GS5-45HPC-D HP + ECO-119GLBK and how do you decode its serial?

CPSC records show 0 active plumbing recalls for SANCO2 as of 2026-11-23. Confirm install proof and serial manufacture year on SANCO2 GS5-45HPC-D HP + ECO-119GLBK before calling service.

How do 2026 post-OBBBA rebates affect buying SANCO2 GS5-45HPC-D HP + ECO-119GLBK?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is Reclaim Energy MP120F-RC (3.75 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks