Skip to main content
ENERGY STAR water heater model · PD 3624319

SANCO2 GS5-45HPC HP + ECO-119GLBK Water Heater Specifications (3.72 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, SANCO2 GS5-45HPC HP + ECO-119GLBK (Electric) achieves a certified 3.72 UEF rating across its 119-gallon nominal tank, 134 gal First Hour Rating (rank #345 of 706, PD 3624319) and verifies as Pass: +1.22 / +48.8% for 2029 DOE floors. Rated annual electricity draw of 1,333 kWh/yr equates to roughly $242/yr ($2,421 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Reclaim Energy MP120F-RC (3.75 UEF).

Uniform Energy Factor
3.72 UEF
Cohort UEF Rank
#345 of 706
First Hour Rating
134 gal
Storage Volume
119 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.22 / +48.8%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking SANCO2 GS5-45HPC HP + ECO-119GLBK at 3.72 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50SANCO2 GS5-45HPC HP + ECO-119GLBK: 3.72
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows SANCO2 GS5-45HPC HP + ECO-119GLBK relative to the cohort median.
Efficiency comparison & rule summary

SANCO2 GS5-45HPC HP + ECO-119GLBK records 3.72 UEF efficiency, putting it #345 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: SANCO2 GS5-45HPC HP + ECO-119GLBK exceeds 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.22 UEF (+48.8%). At EIA August 2026 national rates (18.16 cents/kWh), 1,333 kWh/yr for SANCO2 GS5-45HPC HP + ECO-119GLBK runs ~$242/yr vs. ~$979/yr for a 0.92 UEF electric tank. Acoustic output is 37 dBA (quieter than 93.3% of Hybrid/Electric Heat Pump models).

State electric sensitivity for SANCO2 GS5-45HPC HP + ECO-119GLBK: 10-year operating spend spans $1,950 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,289 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside SANCO2 GS5-45HPC HP + ECO-119GLBK (3.72 UEF) are Reclaim Energy MP120F-RC (3.75 UEF, delta +0.03) and VAUGHN THERMAL MP120F-RC (3.75 UEF, delta +0.03).

How Complete Are the Certified Metrics for SANCO2 GS5-45HPC HP + ECO-119GLBK?

Standing at #345 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, SANCO2 GS5-45HPC HP + ECO-119GLBK brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandSANCO26 certified listingsENERGY STAR PD 3624319
Model NumberGS5-45HPC HP + ECO-119GLBKDraw pattern: High-UsageGS5-45HPC HP + ECO-119GLBK
Uniform Energy Factor (UEF)3.72+0.02 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)134 gal+62 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,333 kWh/yr+261 kWh/yr vs. 1,072 kWh/yr medianEst. $242/yr @ $0.1816/kWh (EIA US Avg)
Electrical Circuit Requirements230 V / 7 A maxVerify rating plate electrical drawNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-744 (CO₂) (GWP:1 | Lower GWP)Lower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Sound Pressure Level37 dBAtop 6.7% · quieter than 93.3% of Hybrid/Electric Heat Pump models · -12 dBA vs. 49 dBA medianIndoor placement check
Certification Date2024-08-21Certified 2024-08-21Markets: United States, Canada

What Is the Projected Utility Bill for GS5-45HPC HP + ECO-119GLBK by State?

At 1,333 kWh/yr, SANCO2 GS5-45HPC HP + ECO-119GLBK averages about $242/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Estimated Annual Electricity Cost by State Rate (1,333 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$242.00/yrHawaii$629.00/yrCalifornia$397.00/yrTexas$212.00/yrWashington$195.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $242/yr $2,421 $7,368
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $629/yr $6,289 $19,141
California 29.75 ¢/kWh ($0.2975) $397/yr $3,966 $12,070
Texas 15.91 ¢/kWh ($0.1591) $212/yr $2,121 $6,455
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $195/yr $1,950 $5,935
Estimated electricity spend (1,333 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are SANCO2 Models Affected by Current CPSC Notices?

Zero brand-level CPSC hazard notices matched SANCO2 in our 2026-11-23 feed; decode your water heater's serial number below to confirm warranty status. See Serial Number Lookup.

Which 5 Models Offer Similar Output to GS5-45HPC HP + ECO-119GLBK?

Ordered by minimal capacity and UEF spread relative to SANCO2 GS5-45HPC HP + ECO-119GLBK, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Reclaim Energy MP120F-RC Hybrid/Electric Heat Pump 119 gal 121 gal 3.75 (+0.03) 1,296
VAUGHN THERMAL MP120F-RC Hybrid/Electric Heat Pump 119 gal 121 gal 3.75 (+0.03) 1,296
Smart Solar SSG2-ES 120 Hybrid/Electric Heat Pump 120 gal 83 gal 2.85 (-0.87) 1,741
Hubbell ME120HPT Hybrid/Electric Heat Pump 109 gal 105 gal 3.38 (-0.34) 1,467
VAUGHN THERMAL MP120FHPT Hybrid/Electric Heat Pump 119 gal 115 gal 3.5 (-0.22) 1,418

What Are the Limitations of SANCO2 GS5-45HPC HP + ECO-119GLBK and Who Should Not Install It?

Before ordering SANCO2 GS5-45HPC HP + ECO-119GLBK (Hybrid/Electric Heat Pump, 3.72 UEF), weigh space clearances, fuel piping, noise (37 dBA), and 2029 rule readiness across three scenarios.

Key Limitations & Exclusions

  • SANCO2 GS5-45HPC HP + ECO-119GLBK needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 37 dBA; avoid mounting SANCO2 GS5-45HPC HP + ECO-119GLBK directly beside quiet bedrooms.
  • Requires condensate drain routing and 230V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing SANCO2 GS5-45HPC HP + ECO-119GLBK Strong Fit — 3.72 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Reclaim Energy MP120F-RC footprint.

Practical Specs & Code Questions for SANCO2 GS5-45HPC HP + ECO-119GLBK

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does SANCO2 GS5-45HPC HP + ECO-119GLBK pass the May 6, 2029 federal DOE efficiency rule?

SANCO2 GS5-45HPC HP + ECO-119GLBK carries a verified 3.72 UEF rating (Pass: +1.22 / +48.8%), ranking #345 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

What doorway width and ceiling height does SANCO2 GS5-45HPC HP + ECO-119GLBK need?

SANCO2 GS5-45HPC HP + ECO-119GLBK mounts as a hybrid/electric heat pump without a bulky floor tank (wall-hung / compact envelope). Verify vent termination distances and combustion air clearances per IPC or UPC.

What gas pipe size or electrical breaker does SANCO2 GS5-45HPC HP + ECO-119GLBK require?

SANCO2 GS5-45HPC HP + ECO-119GLBK uses a 230V branch circuit at 7A max (Verify rating plate electrical draw). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

How much electricity or energy does SANCO2 GS5-45HPC HP + ECO-119GLBK cost per year to run?

Rated at 1,333 kWh/yr, SANCO2 GS5-45HPC HP + ECO-119GLBK costs about $242/yr ($2,420 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $195/yr in Washington hydro tiers up to $629/yr in Hawaii).

Who should NOT install SANCO2 GS5-45HPC HP + ECO-119GLBK, and what are its limits?

SANCO2 GS5-45HPC HP + ECO-119GLBK (3.72 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 37 dBA.

How many bathrooms or people can SANCO2 GS5-45HPC HP + ECO-119GLBK serve at peak demand?

SANCO2 GS5-45HPC HP + ECO-119GLBK achieves a 134 gal First Hour Rating (+62 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

Are there CPSC safety recalls or serial checks for SANCO2 GS5-45HPC HP + ECO-119GLBK?

No active CPSC recalls matched SANCO2 as of 2026-11-23. Always decode the serial tag on SANCO2 GS5-45HPC HP + ECO-119GLBK because OEM tank/exchanger warranties span 6–12 years.

What 2026 rebates apply to SANCO2 GS5-45HPC HP + ECO-119GLBK, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is Reclaim Energy MP120F-RC (3.75 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks