RELIANCE WATER HEATERS 10-66-DHPHTNE 1** Water Heater Specifications (3.45 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, RELIANCE WATER HEATERS 10-66-DHPHTNE 1** achieves a certified 3.45 UEF rating across its 67-gallon nominal tank, 79 gal First Hour Rating and ranks #563 of 706 in its 706-model cohort (PD 2408872), recording Pass: +0.95 / +38.0% under 2029 DOE rules. Rated annual electricity draw of 1,381 kWh/yr equates to roughly $251/yr ($2,508 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPTU-66CTA 1** (3.45 UEF).

Uniform Energy Factor
3.45 UEF
Cohort UEF Rank
#563 of 706
First Hour Rating
79 gal
Storage Volume
67 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +0.95 / +38.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking RELIANCE WATER HEATERS 10-66-DHPHTNE 1** at 3.45 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50RELIANCE WATER HEATERS 10-66-DHPHTNE 1**: 3.45
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows RELIANCE WATER HEATERS 10-66-DHPHTNE 1** relative to the cohort median.
Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, RELIANCE WATER HEATERS 10-66-DHPHTNE 1** logs 3.45 UEF and ranks #563 of 706.

Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), RELIANCE WATER HEATERS 10-66-DHPHTNE 1** holds a +0.95 UEF (+38.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,381 kWh/yr for RELIANCE WATER HEATERS 10-66-DHPHTNE 1** runs ~$251/yr vs. ~$941/yr for a 0.92 UEF electric tank.

State electric sensitivity for RELIANCE WATER HEATERS 10-66-DHPHTNE 1**: 10-year operating spend spans $2,020 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,516 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping RELIANCE WATER HEATERS 10-66-DHPHTNE 1** (3.45 UEF)? Check A. O. Smith HPTU-66CTA 1** (3.45 UEF, at parity) and American HPHE10266H045DVCTA-1** (3.45 UEF, at parity).

Which Specs Set RELIANCE WATER HEATERS 10-66-DHPHTNE 1** Apart From Cohort Averages?

Ranked #563 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, RELIANCE WATER HEATERS 10-66-DHPHTNE 1** is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRELIANCE WATER HEATERS71 certified listingsENERGY STAR PD 2408872
Model Number10-66-DHPHTNE 1**Draw pattern: High-Usage10-66-DHPHTNE 1**
Uniform Energy Factor (UEF)3.45-0.25 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)79 gal+7 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,381 kWh/yr+309 kWh/yr vs. 1,072 kWh/yr medianEst. $251/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency265%-164.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)61" H x 23" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 22 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2023-02-23Certified 2023-02-23Markets: United States, Canada

How Do Regional kWh Prices Impact 10-66-DHPHTNE 1** Over 10 Years?

Using EIA Table 5.6.A benchmarks, RELIANCE WATER HEATERS 10-66-DHPHTNE 1**'s 1,381 kWh/yr draw translates to roughly $251/yr on typical US residential bills.

Estimated Annual Electricity Cost by State Rate (1,381 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$251.00/yrHawaii$652.00/yrCalifornia$411.00/yrTexas$220.00/yrWashington$202.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $251/yr $2,508 $6,897
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $652/yr $6,516 $17,919
California 29.75 ¢/kWh ($0.2975) $411/yr $4,108 $11,299
Texas 15.91 ¢/kWh ($0.1591) $220/yr $2,197 $6,043
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $202/yr $2,020 $5,556
Estimated electricity spend (1,381 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should RELIANCE WATER HEATERS Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC SaferProducts snapshot includes 3 filings tied to RELIANCE WATER HEATERS; verify whether your 10-66-DHPHTNE 1** production run falls inside affected ranges. See Serial Number Lookup.

3 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #04128 (2004-04-28): CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls (CPSC Notice)

How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith HPTU-66CTA 1** Hybrid/Electric Heat Pump 67 gal 79 gal 3.45 (at parity) 1,381
American HPHE10266H045DVCTA-1** Hybrid/Electric Heat Pump 67 gal 79 gal 3.45 (at parity) 1,381
Lochinvar HPA068KD 1** Hybrid/Electric Heat Pump 67 gal 79 gal 3.45 (at parity) 1,381
State HPX-66-DHPTCTA 1** Hybrid/Electric Heat Pump 67 gal 79 gal 3.45 (at parity) 1,381
A. O. Smith HPTU-66DR 1** Hybrid/Electric Heat Pump 67 gal 79 gal 3.45 (at parity) 1,381

What Are the Limitations of RELIANCE WATER HEATERS 10-66-DHPHTNE 1** and Who Should Not Install It?

Before ordering RELIANCE WATER HEATERS 10-66-DHPHTNE 1** (Hybrid/Electric Heat Pump, 3.45 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

Key Limitations & Exclusions

  • RELIANCE WATER HEATERS 10-66-DHPHTNE 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting RELIANCE WATER HEATERS 10-66-DHPHTNE 1** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing RELIANCE WATER HEATERS 10-66-DHPHTNE 1** Strong Fit — 3.45 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith HPTU-66CTA 1** footprint.

Frequently Asked Technical Questions: RELIANCE WATER HEATERS 10-66-DHPHTNE 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does RELIANCE WATER HEATERS 10-66-DHPHTNE 1** pass the May 6, 2029 federal DOE efficiency rule?

RELIANCE WATER HEATERS 10-66-DHPHTNE 1** carries a verified 3.45 UEF rating (Pass: +0.95 / +38.0%), ranking #563 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

What doorway width and ceiling height does RELIANCE WATER HEATERS 10-66-DHPHTNE 1** need?

RELIANCE WATER HEATERS 10-66-DHPHTNE 1** stands 61 in. high with a 23 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

What gas pipe size or electrical breaker does RELIANCE WATER HEATERS 10-66-DHPHTNE 1** require?

RELIANCE WATER HEATERS 10-66-DHPHTNE 1** uses a 240V branch circuit at 22A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

How much electricity or energy does RELIANCE WATER HEATERS 10-66-DHPHTNE 1** cost per year to run?

Rated at 1,381 kWh/yr, RELIANCE WATER HEATERS 10-66-DHPHTNE 1** costs about $251/yr ($2,510 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $202/yr in Washington hydro tiers up to $652/yr in Hawaii).

Who should NOT install RELIANCE WATER HEATERS 10-66-DHPHTNE 1**, and what are its limits?

RELIANCE WATER HEATERS 10-66-DHPHTNE 1** (3.45 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.

How many bathrooms or people can RELIANCE WATER HEATERS 10-66-DHPHTNE 1** serve at peak demand?

RELIANCE WATER HEATERS 10-66-DHPHTNE 1** achieves a 79 gal First Hour Rating (+7 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

Are there CPSC safety recalls or serial checks for RELIANCE WATER HEATERS 10-66-DHPHTNE 1**?

CPSC SaferProducts records show 3 brand-level recall notices mentioning RELIANCE WATER HEATERS as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

What 2026 rebates apply to RELIANCE WATER HEATERS 10-66-DHPHTNE 1**, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPTU-66CTA 1** (3.45 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)