Rheem CPROPH65 T2 RH400-SO Water Heater Specifications (4.05 UEF)
Certified at 4.05 UEF across its 59-gallon nominal tank, 75 gal First Hour Rating, Rheem CPROPH65 T2 RH400-SO (Hybrid/Electric Heat Pump, Electric) places #61 of 706 out of 706 ENERGY STAR models (PD 3554226). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.55 / +62.0%. Rated annual electricity draw of 1,184 kWh/yr equates to roughly $215/yr ($2,150 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH65 T2 FD400-30 (4.05 UEF).
- Uniform Energy Factor
- 4.05 UEF
- Cohort UEF Rank
- #61 of 706 (top 14.2%)
- First Hour Rating
- 75 gal
- Storage Volume
- 59 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.55 / +62.0%

Tested at 4.05 UEF, Rheem CPROPH65 T2 RH400-SO places #61 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (+0.35 UEF vs. 3.70 UEF median).
Rheem CPROPH65 T2 RH400-SO clears 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.55 UEF (+62.0% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 1,184 kWh/yr for Rheem CPROPH65 T2 RH400-SO runs ~$215/yr vs. ~$946/yr for a 0.92 UEF electric tank.
State electric sensitivity for Rheem CPROPH65 T2 RH400-SO: 10-year operating spend spans $1,732 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,586 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Closest alternatives to Rheem CPROPH65 T2 RH400-SO include Friedrich PROH65 T2 FD400-30 (4.05 UEF, at parity) alongside Richmond 10CE65-HP5S30 (4.05 UEF, at parity).
How Complete Are the Certified Metrics for Rheem CPROPH65 T2 RH400-SO?
Standing at #61 of 706 (top 14.2%) among 706 certified Hybrid/Electric Heat Pump heaters, Rheem CPROPH65 T2 RH400-SO brings measurable deltas in recovery, footprint, and energy efficiency.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Rheem | 236 certified listings | ENERGY STAR PD 3554226 |
| Model Number | CPROPH65 T2 RH400-SO | Draw pattern: High-Usage | CPROPH65 T2 RH400-SO |
| Uniform Energy Factor (UEF) | 4.05 | +0.35 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 75 gal | +3 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,184 kWh/yr | +112 kWh/yr vs. 1,072 kWh/yr median | Est. $215/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 457% | +28.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 64.2" H x 24.3" D | Verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: Canada |
What Is the Projected Utility Bill for CPROPH65 T2 RH400-SO by State?
At 1,184 kWh/yr, Rheem CPROPH65 T2 RH400-SO averages about $215/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $215/yr | $2,150 | $7,315 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $559/yr | $5,586 | $19,004 |
| California | 29.75 ¢/kWh ($0.2975) | $352/yr | $3,522 | $11,983 |
| Texas | 15.91 ¢/kWh ($0.1591) | $188/yr | $1,884 | $6,409 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $173/yr | $1,732 | $5,893 |
Are Rheem Models Affected by Current CPSC Notices?
Review 4 brand-matched CPSC entries pulled 2026-11-23 for Rheem and confirm your serial tag before scheduling contractor service. See Serial Number Lookup.
- Recall #16177 (2016-05-26): Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot (CPSC Notice)
- Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
- Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
Which 5 Models Offer Similar Output to CPROPH65 T2 RH400-SO?
Ordered by minimal capacity and UEF spread relative to Rheem CPROPH65 T2 RH400-SO, these five certified peers give direct replacement benchmarks.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Friedrich PROH65 T2 FD400-30 | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 4.05 (at parity) | 1,184 |
| Richmond 10CE65-HP5S30 | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 4.05 (at parity) | 1,289 |
| Ruud CPROPH65 T2 CD375-30 | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 4.05 (at parity) | 1,213 |
| Bosch TR7000T-65CA | Hybrid/Electric Heat Pump | 60 gal | 80 gal | 3.9 (-0.15) | 1,240 |
| Friedrich PROH65 T2 FD400-SO | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 4.05 (at parity) | 1,184 |
What Are the Limitations of Rheem CPROPH65 T2 RH400-SO and Who Should Not Install It?
Before ordering Rheem CPROPH65 T2 RH400-SO (Hybrid/Electric Heat Pump, 4.05 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.
Key Limitations & Exclusions
- Rheem CPROPH65 T2 RH400-SO needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Rheem CPROPH65 T2 RH400-SO directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Practical Specs & Code Questions for Rheem CPROPH65 T2 RH400-SO
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Does Rheem CPROPH65 T2 RH400-SO pass the May 6, 2029 federal DOE efficiency rule?
Rheem CPROPH65 T2 RH400-SO carries a verified 4.05 UEF rating (Pass: +1.55 / +62.0%), ranking #61 of 706 (top 14.2%) across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.
What doorway width and ceiling height does Rheem CPROPH65 T2 RH400-SO need?
Rheem CPROPH65 T2 RH400-SO stands 64.2 in. high with a 24.3 in. diameter; verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.
What gas pipe size or electrical breaker does Rheem CPROPH65 T2 RH400-SO require?
Rheem CPROPH65 T2 RH400-SO uses a 240V branch circuit at 21A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.
How much electricity or energy does Rheem CPROPH65 T2 RH400-SO cost per year to run?
Rated at 1,184 kWh/yr, Rheem CPROPH65 T2 RH400-SO costs about $215/yr ($2,150 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $173/yr in Washington hydro tiers up to $559/yr in Hawaii).
Who should NOT install Rheem CPROPH65 T2 RH400-SO, and what are its limits?
Rheem CPROPH65 T2 RH400-SO (4.05 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.
How many bathrooms or people can Rheem CPROPH65 T2 RH400-SO serve at peak demand?
Rheem CPROPH65 T2 RH400-SO achieves a 75 gal First Hour Rating (+3 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.
Are there CPSC safety recalls or serial checks for Rheem CPROPH65 T2 RH400-SO?
CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
What 2026 rebates apply to Rheem CPROPH65 T2 RH400-SO, and what peer compares closest?
Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH65 T2 FD400-30 (4.05 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)