Skip to main content
ENERGY STAR water heater model · PD 3554227

Rheem CXE65T10H45U1 Water Heater Specifications (4.05 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, Rheem CXE65T10H45U1 achieves a certified 4.05 UEF rating across its 59-gallon nominal tank, 75 gal First Hour Rating and ranks #61 of 706 in its 706-model cohort (PD 3554227), recording Pass: +1.55 / +62.0% under 2029 DOE rules. Rated annual electricity draw of 1,184 kWh/yr equates to roughly $215/yr ($2,150 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH65 T2 FD400-30 (4.05 UEF).

Uniform Energy Factor
4.05 UEF
Cohort UEF Rank
#61 of 706 (top 14.2%)
First Hour Rating
75 gal
Storage Volume
59 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.55 / +62.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Rheem CXE65T10H45U1 at 4.05 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Rheem CXE65T10H45U1: 4.05
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Rheem CXE65T10H45U1 relative to the cohort median.
Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, Rheem CXE65T10H45U1 logs 4.05 UEF and ranks #61 of 706.

Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), Rheem CXE65T10H45U1 holds a +1.55 UEF (+62.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,184 kWh/yr for Rheem CXE65T10H45U1 runs ~$215/yr vs. ~$946/yr for a 0.92 UEF electric tank.

State electric sensitivity for Rheem CXE65T10H45U1: 10-year operating spend spans $1,732 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,586 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping Rheem CXE65T10H45U1 (4.05 UEF)? Check Friedrich PROH65 T2 FD400-30 (4.05 UEF, at parity) and Richmond 10CE65-HP5S30 (4.05 UEF, at parity).

How Complete Are the Certified Metrics for Rheem CXE65T10H45U1?

Standing at #61 of 706 (top 14.2%) among 706 certified Hybrid/Electric Heat Pump heaters, Rheem CXE65T10H45U1 brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRheem236 certified listingsENERGY STAR PD 3554227
Model NumberCXE65T10H45U1Draw pattern: High-UsageCXE65T10H45U1
Uniform Energy Factor (UEF)4.05+0.35 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)75 gal+3 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,184 kWh/yr+112 kWh/yr vs. 1,072 kWh/yr medianEst. $215/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency457%+28.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)64.2" H x 24.3" DVerify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 21 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-10-15Certified 2026-10-15Markets: Canada

What Is the Projected Utility Bill for CXE65T10H45U1 by State?

At 1,184 kWh/yr, Rheem CXE65T10H45U1 averages about $215/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Estimated Annual Electricity Cost by State Rate (1,184 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$215.00/yrHawaii$559.00/yrCalifornia$352.00/yrTexas$188.00/yrWashington$173.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $215/yr $2,150 $7,315
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $559/yr $5,586 $19,004
California 29.75 ¢/kWh ($0.2975) $352/yr $3,522 $11,983
Texas 15.91 ¢/kWh ($0.1591) $188/yr $1,884 $6,409
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $173/yr $1,732 $5,893
Estimated electricity spend (1,184 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are Rheem Models Affected by Current CPSC Notices?

Review 4 brand-matched CPSC entries pulled 2026-11-23 for Rheem and confirm your serial tag before scheduling contractor service. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #16177 (2016-05-26): Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot (CPSC Notice)
  • Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
  • Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

Which 5 Models Offer Similar Output to CXE65T10H45U1?

Ordered by minimal capacity and UEF spread relative to Rheem CXE65T10H45U1, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH65 T2 FD400-30 Hybrid/Electric Heat Pump 59 gal 75 gal 4.05 (at parity) 1,184
Richmond 10CE65-HP5S30 Hybrid/Electric Heat Pump 59 gal 75 gal 4.05 (at parity) 1,289
Ruud CPROPH65 T2 CD375-30 Hybrid/Electric Heat Pump 59 gal 75 gal 4.05 (at parity) 1,213
Bosch TR7000T-65CA Hybrid/Electric Heat Pump 60 gal 80 gal 3.9 (-0.15) 1,240
Friedrich PROH65 T2 FD400-SO Hybrid/Electric Heat Pump 59 gal 75 gal 4.05 (at parity) 1,184

When Should Homeowners Skip Rheem CXE65T10H45U1 (Hybrid/Electric Heat Pump)?

Check Rheem CXE65T10H45U1's mechanical constraints—including utility space, Electric capacity, and Pass: +1.55 / +62.0% status—against typical residential installations.

Key Limitations & Exclusions

  • Rheem CXE65T10H45U1 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Rheem CXE65T10H45U1 directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Rheem CXE65T10H45U1 Strong Fit — 4.05 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH65 T2 FD400-30 footprint.

Practical Specs & Code Questions for Rheem CXE65T10H45U1

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will Rheem CXE65T10H45U1 stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 4.05 UEF, Rheem CXE65T10H45U1 shows Pass: +1.55 / +62.0% relative to May 6, 2029 federal DOE limits while placing #61 of 706 (top 14.2%) among 706 Hybrid/Electric Heat Pump peers like Friedrich PROH65 T2 FD400-30.

Will Rheem CXE65T10H45U1 fit through a standard utility door and 72-inch basement ceiling?

Measuring 64.2 in. tall by 24.3 in. diameter, Rheem CXE65T10H45U1 notes: verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" d). Reserve space above the jacket for T&P piping and anode removal.

Do existing utility hookups support Rheem CXE65T10H45U1 during replacement?

Electrical specs for Rheem CXE65T10H45U1 call for 240V at 21A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

What is the estimated 10-year operating spend for Rheem CXE65T10H45U1?

At 18.16 cents/kWh national residential pricing, Rheem CXE65T10H45U1's 1,184 kWh/yr draw equals roughly $215 annually or $2,150 across a 10-year horizon (ranging from $173/yr in Washington hydro tiers up to $559/yr in Hawaii).

When is Rheem CXE65T10H45U1 a poor fit for a residential replacement?

Avoid placing Rheem CXE65T10H45U1 directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

What First Hour Rating or flow capacity does Rheem CXE65T10H45U1 deliver?

With 75 gal FHR (+3 gal vs. 72 gal median), Rheem CXE65T10H45U1 fits larger 3–5 person homes cleanly.

How do you verify manufacturing age and recall status on Rheem CXE65T10H45U1?

CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Does Rheem CXE65T10H45U1 qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Rheem CXE65T10H45U1. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH65 T2 FD400-30 (4.05 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks