Rheem ECEPH50 T2 RH350BM Water Heater Specifications (3.5 UEF)
Engineered as a Electric Hybrid/Electric Heat Pump unit, Rheem ECEPH50 T2 RH350BM achieves a certified 3.5 UEF rating across its 45-gallon nominal tank, 67 gal First Hour Rating and ranks #481 of 706 in its 706-model cohort (PD 3994207), recording Pass: +1.20 / +52.2% under 2029 DOE rules. Rated annual electricity draw of 915 kWh/yr equates to roughly $166/yr ($1,662 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH50 T2 FD310BM (3.5 UEF).
- Uniform Energy Factor
- 3.5 UEF
- Cohort UEF Rank
- #481 of 706
- First Hour Rating
- 67 gal
- Storage Volume
- 45 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.20 / +52.2%

Within the 706-unit Hybrid/Electric Heat Pump cohort, Rheem ECEPH50 T2 RH350BM logs 3.5 UEF and ranks #481 of 706.
Against 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF), Rheem ECEPH50 T2 RH350BM holds a +1.20 UEF (+52.2%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 915 kWh/yr for Rheem ECEPH50 T2 RH350BM runs ~$166/yr vs. ~$632/yr for a 0.92 UEF electric tank.
State electric sensitivity for Rheem ECEPH50 T2 RH350BM: 10-year operating spend spans $1,339 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,317 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Cross-shopping Rheem ECEPH50 T2 RH350BM (3.5 UEF)? Check Friedrich PROH50 T2 FD310BM (3.5 UEF, at parity) and Ruud PRO H50 T2 RU310BM (3.5 UEF, at parity).
What Physical and Thermal Ratings Define Rheem ECEPH50 T2 RH350BM?
Positioning at #481 of 706 out of 706 Hybrid/Electric Heat Pump peers, Rheem ECEPH50 T2 RH350BM pairs measured UEF performance with specific clearance and wiring rules.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Rheem | 236 certified listings | ENERGY STAR PD 3994207 |
| Model Number | ECEPH50 T2 RH350BM | Draw pattern: Medium-Usage | ECEPH50 T2 RH350BM |
| Uniform Energy Factor (UEF) | 3.5 | -0.20 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 67 gal | -5 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 915 kWh/yr | -157 kWh/yr vs. 1,072 kWh/yr median | Est. $166/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 400% | -29.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 61.8" H x 22.3" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: Canada |
Why Do State Utility Rates Shift ECEPH50 T2 RH350BM Running Costs?
Consuming 915 kWh annually puts Rheem ECEPH50 T2 RH350BM near $166/yr at US baseline tariffs, with multi-state EIA comparisons charted below.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $166/yr | $1,662 | $4,660 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $432/yr | $4,317 | $12,106 |
| California | 29.75 ¢/kWh ($0.2975) | $272/yr | $2,722 | $7,634 |
| Texas | 15.91 ¢/kWh ($0.1591) | $146/yr | $1,456 | $4,083 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $134/yr | $1,339 | $3,754 |
Have Any Rheem Series Triggered CPSC Recalls?
SaferProducts records retrieved 2026-11-23 list 4 brand notices under Rheem; inspect model coverage dates prior to valve or anode service. See Serial Number Lookup.
- Recall #16177 (2016-05-26): Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot (CPSC Notice)
- Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
- Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
What Are 5 Direct Alternatives to Rheem ECEPH50 T2 RH350BM?
Homeowners cross-shopping Rheem ECEPH50 T2 RH350BM frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Friedrich PROH50 T2 FD310BM | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.5 (at parity) | 915 |
| Ruud PRO H50 T2 RU310BM | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.5 (at parity) | 915 |
| A. O. Smith HPACO-45 1**+AXST-50T 1** | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.52 (+0.02) | 923 |
| American MHPCO-45 1**+MXST-50T 1** | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.52 (+0.02) | 923 |
| Friedrich PROH50 T2 FD310UM | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.5 (at parity) | 915 |
What Are the Limitations of Rheem ECEPH50 T2 RH350BM and Who Should Not Install It?
Before ordering Rheem ECEPH50 T2 RH350BM (Hybrid/Electric Heat Pump, 3.5 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.
Key Limitations & Exclusions
- Rheem ECEPH50 T2 RH350BM needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Rheem ECEPH50 T2 RH350BM directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Sizing, Efficiency & Recall Answers for Rheem ECEPH50 T2 RH350BM
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Does Rheem ECEPH50 T2 RH350BM pass the May 6, 2029 federal DOE efficiency rule?
Rheem ECEPH50 T2 RH350BM carries a verified 3.5 UEF rating (Pass: +1.20 / +52.2%), ranking #481 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.
What doorway width and ceiling height does Rheem ECEPH50 T2 RH350BM need?
Rheem ECEPH50 T2 RH350BM stands 61.8 in. high with a 22.3 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.
What gas pipe size or electrical breaker does Rheem ECEPH50 T2 RH350BM require?
Rheem ECEPH50 T2 RH350BM uses a 240V branch circuit at 21A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.
How much electricity or energy does Rheem ECEPH50 T2 RH350BM cost per year to run?
Rated at 915 kWh/yr, Rheem ECEPH50 T2 RH350BM costs about $166/yr ($1,660 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $134/yr in Washington hydro tiers up to $432/yr in Hawaii).
Who should NOT install Rheem ECEPH50 T2 RH350BM, and what are its limits?
Rheem ECEPH50 T2 RH350BM (3.5 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.
How many bathrooms or people can Rheem ECEPH50 T2 RH350BM serve at peak demand?
Rheem ECEPH50 T2 RH350BM achieves a 67 gal First Hour Rating (-5 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.
Are there CPSC safety recalls or serial checks for Rheem ECEPH50 T2 RH350BM?
CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
What 2026 rebates apply to Rheem ECEPH50 T2 RH350BM, and what peer compares closest?
Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH50 T2 FD310BM (3.5 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)