Skip to main content
ENERGY STAR water heater model · PD 3554220

Rheem PROPH65 T2 RH400-30 Water Heater Specifications (4.05 UEF)

The Rheem PROPH65 T2 RH400-30 (Hybrid/Electric Heat Pump, Electric) achieves a certified 4.05 UEF rating across its 59-gallon nominal tank, 75 gal First Hour Rating, ranking #61 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 3554220). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.55 / +62.0%. Rated annual electricity draw of 1,184 kWh/yr equates to roughly $215/yr ($2,150 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH65 T2 FD400-30 (4.05 UEF).

Uniform Energy Factor
4.05 UEF
Cohort UEF Rank
#61 of 706 (top 14.2%)
First Hour Rating
75 gal
Storage Volume
59 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.55 / +62.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Rheem PROPH65 T2 RH400-30 at 4.05 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Rheem PROPH65 T2 RH400-30: 4.05
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Rheem PROPH65 T2 RH400-30 relative to the cohort median.
Efficiency comparison & rule summary

Rheem PROPH65 T2 RH400-30 (4.05 UEF) ranks #61 of 706 Hybrid/Electric Heat Pump models — 40-way tie; top 14.2%, more efficient than 85.8% of Hybrid/Electric Heat Pump models, +0.35 UEF above the 3.70 UEF median.

Federal 2029 margin for Rheem PROPH65 T2 RH400-30: +1.55 UEF (+62.0%) vs. 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,184 kWh/yr for Rheem PROPH65 T2 RH400-30 runs ~$215/yr vs. ~$946/yr for a 0.92 UEF electric tank.

State electric sensitivity for Rheem PROPH65 T2 RH400-30: 10-year operating spend spans $1,732 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,586 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: Rheem PROPH65 T2 RH400-30 (4.05 UEF) compares closely with Friedrich PROH65 T2 FD400-30 (4.05 UEF, at parity) and Richmond 10CE65-HP5S30 (4.05 UEF, at parity).

How Do Rheem PROPH65 T2 RH400-30 Specs Compare to Hybrid/Electric Heat Pump Medians?

Rheem PROPH65 T2 RH400-30 places #61 of 706 (top 14.2%) across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRheem236 certified listingsENERGY STAR PD 3554220
Model NumberPROPH65 T2 RH400-30Draw pattern: High-UsagePROPH65 T2 RH400-30
Uniform Energy Factor (UEF)4.05+0.35 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)75 gal+3 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,184 kWh/yr+112 kWh/yr vs. 1,072 kWh/yr medianEst. $215/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency457%+28.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)64.2" H x 24.3" DVerify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 21 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-10-15Certified 2026-10-15Markets: United States

What Does PROPH65 T2 RH400-30 Cost to Operate Across State Electricity Rates?

At 1,184 kWh/yr, Rheem PROPH65 T2 RH400-30 runs roughly $215/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Estimated Annual Electricity Cost by State Rate (1,184 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$215.00/yrHawaii$559.00/yrCalifornia$352.00/yrTexas$188.00/yrWashington$173.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $215/yr $2,150 $7,315
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $559/yr $5,586 $19,004
California 29.75 ¢/kWh ($0.2975) $352/yr $3,522 $11,983
Texas 15.91 ¢/kWh ($0.1591) $188/yr $1,884 $6,409
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $173/yr $1,732 $5,893
Estimated electricity spend (1,184 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for Rheem Water Heaters?

Our 2026-11-23 CPSC SaferProducts query surfaced 4 brand-level recall notices associated with Rheem; match your serial plate before repair. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #16177 (2016-05-26): Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot (CPSC Notice)
  • Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
  • Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

Which Certified Water Heaters Match PROPH65 T2 RH400-30 Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to Rheem PROPH65 T2 RH400-30 by storage capacity and 4.05 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH65 T2 FD400-30 Hybrid/Electric Heat Pump 59 gal 75 gal 4.05 (at parity) 1,184
Richmond 10CE65-HP5S30 Hybrid/Electric Heat Pump 59 gal 75 gal 4.05 (at parity) 1,289
Ruud CPROPH65 T2 CD375-30 Hybrid/Electric Heat Pump 59 gal 75 gal 4.05 (at parity) 1,213
Bosch TR7000T-65CA Hybrid/Electric Heat Pump 60 gal 80 gal 3.9 (-0.15) 1,240
Friedrich PROH65 T2 FD400-SO Hybrid/Electric Heat Pump 59 gal 75 gal 4.05 (at parity) 1,184

Who Is Rheem PROPH65 T2 RH400-30 Best For — and When Should You Pick Friedrich PROH65 T2 FD400-30?

Evaluate whether Rheem PROPH65 T2 RH400-30's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

Key Limitations & Exclusions

  • Rheem PROPH65 T2 RH400-30 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Rheem PROPH65 T2 RH400-30 directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Rheem PROPH65 T2 RH400-30 Strong Fit — 4.05 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH65 T2 FD400-30 footprint.

What Are the Key Questions About Rheem PROPH65 T2 RH400-30?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Rheem PROPH65 T2 RH400-30 (4.05 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Rheem PROPH65 T2 RH400-30 records 4.05 UEF (Pass: +1.55 / +62.0%), placing #61 of 706 (top 14.2%) out of 706 certified Hybrid/Electric Heat Pump configurations.

Does Rheem PROPH65 T2 RH400-30 fit inside a tight hallway closet or low-headroom utility room?

Rheem PROPH65 T2 RH400-30 requires room for its 64.2 in. vertical shell and 24.3 in. diameter (verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" d)), plus service access for annual sediment draining.

What power supply or fuel line specs govern Rheem PROPH65 T2 RH400-30?

For Rheem PROPH65 T2 RH400-30, plan a 240V circuit at 21A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.

What annual utility bill should homeowners budget for Rheem PROPH65 T2 RH400-30?

Using 1,184 kWh/yr, Rheem PROPH65 T2 RH400-30 generates an estimated $215/yr electric bill at 18.16 cents/kWh (ranging from $173/yr in Washington hydro tiers up to $559/yr in Hawaii)—use the custom rate slider above for your utility tariff.

What are the main drawbacks of Rheem PROPH65 T2 RH400-30 (4.05 UEF)?

Rheem PROPH65 T2 RH400-30 requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or Friedrich PROH65 T2 FD400-30.

What hot-water delivery rating governs Rheem PROPH65 T2 RH400-30?

Rated for 75 gal FHR (+3 gal vs. 72 gal median), Rheem PROPH65 T2 RH400-30 prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

Where do homeowners screen Rheem PROPH65 T2 RH400-30 for recalls and tank age?

CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

What alternative models sit closest to Rheem PROPH65 T2 RH400-30 in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH65 T2 FD400-30 (4.05 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks