Rheem XE40T10HM00U0 Water Heater Specifications (2.8 UEF)
The Rheem XE40T10HM00U0 (Hybrid/Electric Heat Pump, Electric) achieves a certified 2.8 UEF rating across its 36-gallon nominal tank, 45 gal First Hour Rating, ranking #695 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 3555260). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +0.50 / +21.7%. Rated annual electricity draw of 780 kWh/yr equates to roughly $142/yr ($1,416 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH40 T0 FD120-M (2.8 UEF).
- Uniform Energy Factor
- 2.8 UEF
- Cohort UEF Rank
- #695 of 706
- First Hour Rating
- 45 gal
- Storage Volume
- 36 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +0.50 / +21.7%

Rheem XE40T10HM00U0 (2.8 UEF) ranks #695 of 706 Hybrid/Electric Heat Pump models — 10-way tie; more efficient than 0.3% of Hybrid/Electric Heat Pump models, -0.90 UEF below the 3.70 UEF median.
Federal 2029 margin for Rheem XE40T10HM00U0: +0.50 UEF (+21.7%) vs. 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 780 kWh/yr for Rheem XE40T10HM00U0 runs ~$142/yr vs. ~$431/yr for a 0.92 UEF electric tank.
State electric sensitivity for Rheem XE40T10HM00U0: 10-year operating spend spans $1,141 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,680 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Peer comparison: Rheem XE40T10HM00U0 (2.8 UEF) compares closely with Friedrich PROH40 T0 FD120-M (2.8 UEF, at parity) and Richmond 10E40-HP120M (2.8 UEF, at parity).
Which Specs Set Rheem XE40T10HM00U0 Apart From Cohort Averages?
Ranked #695 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, Rheem XE40T10HM00U0 is evaluated row by row below against category medians.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Rheem | 236 certified listings | ENERGY STAR PD 3555260 |
| Model Number | XE40T10HM00U0 | Draw pattern: Low-Usage | XE40T10HM00U0 |
| Uniform Energy Factor (UEF) | 2.8 | -0.90 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 45 gal | -27 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 780 kWh/yr | -292 kWh/yr vs. 1,072 kWh/yr median | Est. $142/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 387% | -42.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 62.3" H x 20.3" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 120 V / 4.5 A max | 120V plug-in retrofit circuit; slower heat-pump-only recovery | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-16 | Certified 2026-10-16 | Markets: United States |
How Do Regional kWh Prices Impact XE40T10HM00U0 Over 10 Years?
Using EIA Table 5.6.A benchmarks, Rheem XE40T10HM00U0's 780 kWh/yr draw translates to roughly $142/yr on typical US residential bills.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $142/yr | $1,416 | $2,895 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $368/yr | $3,680 | $7,520 |
| California | 29.75 ¢/kWh ($0.2975) | $232/yr | $2,320 | $4,742 |
| Texas | 15.91 ¢/kWh ($0.1591) | $124/yr | $1,241 | $2,536 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $114/yr | $1,141 | $2,332 |
What Should Rheem Owners Check in CPSC Recall Logs?
The 2026-11-23 CPSC SaferProducts snapshot includes 4 filings tied to Rheem; verify whether your XE40T10HM00U0 production run falls inside affected ranges. See Serial Number Lookup.
- Recall #16177 (2016-05-26): Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot (CPSC Notice)
- Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
- Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?
Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Friedrich PROH40 T0 FD120-M | Hybrid/Electric Heat Pump | 36 gal | 45 gal | 2.8 (at parity) | 780 |
| Richmond 10E40-HP120M | Hybrid/Electric Heat Pump | 36 gal | 45 gal | 2.8 (at parity) | 780 |
| Ruud PROUH40 T0 RU120-M | Hybrid/Electric Heat Pump | 36 gal | 45 gal | 2.8 (at parity) | 780 |
| A. O. Smith CAHP-40 2** | Hybrid/Electric Heat Pump | 36 gal | 55 gal | 3.6 (+0.80) | 902 |
| Friedrich PROH40 T0 FD120-MSO | Hybrid/Electric Heat Pump | 36 gal | 45 gal | 2.8 (at parity) | 780 |
Who Is Rheem XE40T10HM00U0 Best For — and When Should You Pick Friedrich PROH40 T0 FD120-M?
Evaluate whether Rheem XE40T10HM00U0's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.
Key Limitations & Exclusions
- Rheem XE40T10HM00U0 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Rheem XE40T10HM00U0 directly beside quiet bedrooms.
- Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Frequently Asked Technical Questions: Rheem XE40T10HM00U0
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does Rheem XE40T10HM00U0 (2.8 UEF) compare to 2029 federal DOE floors?
Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Rheem XE40T10HM00U0 records 2.8 UEF (Pass: +0.50 / +21.7%), placing #695 of 706 out of 706 certified Hybrid/Electric Heat Pump configurations.
Does Rheem XE40T10HM00U0 fit inside a tight hallway closet or low-headroom utility room?
Rheem XE40T10HM00U0 requires room for its 62.3 in. vertical shell and 20.3 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" d)), plus service access for annual sediment draining.
What power supply or fuel line specs govern Rheem XE40T10HM00U0?
For Rheem XE40T10HM00U0, plan a 120V circuit at 4.5A max (120V plug-in retrofit circuit; slower heat-pump-only recovery) and keep a dedicated shutoff disconnect within sight of the unit.
What annual utility bill should homeowners budget for Rheem XE40T10HM00U0?
Using 780 kWh/yr, Rheem XE40T10HM00U0 generates an estimated $142/yr electric bill at 18.16 cents/kWh (ranging from $114/yr in Washington hydro tiers up to $368/yr in Hawaii)—use the custom rate slider above for your utility tariff.
What are the main drawbacks of Rheem XE40T10HM00U0 (2.8 UEF)?
Rheem XE40T10HM00U0 requires >=450 cu ft air space, 120V electrical supply, and drain access; tight interior alcoves favor ducted adapters or Friedrich PROH40 T0 FD120-M.
What hot-water delivery rating governs Rheem XE40T10HM00U0?
Rated for 45 gal FHR (-27 gal vs. 72 gal median), Rheem XE40T10HM00U0 prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.
Where do homeowners screen Rheem XE40T10HM00U0 for recalls and tank age?
CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
What alternative models sit closest to Rheem XE40T10HM00U0 in the Hybrid/Electric Heat Pump class?
Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH40 T0 FD120-M (2.8 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)