Rheem XE50T10HS45U0 Water Heater Specifications (3.88 UEF)
Certified at 3.88 UEF across its 45-gallon nominal tank, 67 gal First Hour Rating, Rheem XE50T10HS45U0 (Hybrid/Electric Heat Pump, Electric) places #165 of 706 out of 706 ENERGY STAR models (PD 2408591). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.58 / +68.7%. Rated annual electricity draw of 846 kWh/yr equates to roughly $154/yr ($1,536 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH50 T2 FD400-30 (3.88 UEF).
- Uniform Energy Factor
- 3.88 UEF
- Cohort UEF Rank
- #165 of 706 (top 30.6%)
- First Hour Rating
- 67 gal
- Storage Volume
- 45 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.58 / +68.7%

Tested at 3.88 UEF, Rheem XE50T10HS45U0 places #165 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (+0.18 UEF vs. 3.70 UEF median).
Rheem XE50T10HS45U0 clears 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.58 UEF (+68.7% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 846 kWh/yr for Rheem XE50T10HS45U0 runs ~$154/yr vs. ~$648/yr for a 0.92 UEF electric tank.
State electric sensitivity for Rheem XE50T10HS45U0: 10-year operating spend spans $1,238 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,991 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Closest alternatives to Rheem XE50T10HS45U0 include Friedrich PROH50 T2 FD400-30 (3.88 UEF, at parity) alongside Richmond 10CE50-HP5S30 (3.88 UEF, at parity).
How Do Rheem XE50T10HS45U0 Specs Compare to Hybrid/Electric Heat Pump Medians?
Rheem XE50T10HS45U0 places #165 of 706 (top 30.6%) across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Rheem | 236 certified listings | ENERGY STAR PD 2408591 |
| Model Number | XE50T10HS45U0 | Draw pattern: Medium-Usage | XE50T10HS45U0 |
| Uniform Energy Factor (UEF) | 3.88 | +0.18 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 67 gal | -5 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 846 kWh/yr | -226 kWh/yr vs. 1,072 kWh/yr median | Est. $154/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 430% | +1.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 61.8" H x 22.3" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: United States |
What Does XE50T10HS45U0 Cost to Operate Across State Electricity Rates?
At 846 kWh/yr, Rheem XE50T10HS45U0 runs roughly $154/yr on the EIA national average tier under August 2026 Table 5.6.A rates.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $154/yr | $1,536 | $4,943 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $399/yr | $3,991 | $12,842 |
| California | 29.75 ¢/kWh ($0.2975) | $252/yr | $2,517 | $8,098 |
| Texas | 15.91 ¢/kWh ($0.1591) | $135/yr | $1,346 | $4,331 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $124/yr | $1,238 | $3,982 |
Are There Active CPSC Safety Recalls for Rheem Water Heaters?
Our 2026-11-23 CPSC SaferProducts query surfaced 4 brand-level recall notices associated with Rheem; match your serial plate before repair. See Serial Number Lookup.
- Recall #16177 (2016-05-26): Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot (CPSC Notice)
- Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
- Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
Which Certified Water Heaters Match XE50T10HS45U0 Most Closely?
These 5 competing Hybrid/Electric Heat Pump units sit nearest to Rheem XE50T10HS45U0 by storage capacity and 3.88 UEF rating.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Friedrich PROH50 T2 FD400-30 | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (at parity) | 846 |
| Richmond 10CE50-HP5S30 | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (at parity) | 846 |
| Ruud CPROPH50 T2 CD375-30 | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (at parity) | 846 |
| Bradford White RE2HP50**-1NCTT | Hybrid/Electric Heat Pump | 45 gal | 65 gal | 3.89 (+0.01) | 835 |
| Friedrich PROH50 T2 FD400-SO | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (at parity) | 846 |
When Should Homeowners Skip Rheem XE50T10HS45U0 (Hybrid/Electric Heat Pump)?
Check Rheem XE50T10HS45U0's mechanical constraints—including utility space, Electric capacity, and Pass: +1.58 / +68.7% status—against typical residential installations.
Key Limitations & Exclusions
- Rheem XE50T10HS45U0 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Rheem XE50T10HS45U0 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
What Are the Key Questions About Rheem XE50T10HS45U0?
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Will Rheem XE50T10HS45U0 stay compliant after the May 6, 2029 DOE standard takes effect?
Tested at 3.88 UEF, Rheem XE50T10HS45U0 shows Pass: +1.58 / +68.7% relative to May 6, 2029 federal DOE limits while placing #165 of 706 (top 30.6%) among 706 Hybrid/Electric Heat Pump peers like Friedrich PROH50 T2 FD400-30.
Will Rheem XE50T10HS45U0 fit through a standard utility door and 72-inch basement ceiling?
Measuring 61.8 in. tall by 22.3 in. diameter, Rheem XE50T10HS45U0 notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" d). Reserve space above the jacket for T&P piping and anode removal.
Do existing utility hookups support Rheem XE50T10HS45U0 during replacement?
Electrical specs for Rheem XE50T10HS45U0 call for 240V at 21A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.
What is the estimated 10-year operating spend for Rheem XE50T10HS45U0?
At 18.16 cents/kWh national residential pricing, Rheem XE50T10HS45U0's 846 kWh/yr draw equals roughly $154 annually or $1,540 across a 10-year horizon (ranging from $124/yr in Washington hydro tiers up to $399/yr in Hawaii).
When is Rheem XE50T10HS45U0 a poor fit for a residential replacement?
Avoid placing Rheem XE50T10HS45U0 directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.
What First Hour Rating or flow capacity does Rheem XE50T10HS45U0 deliver?
With 67 gal FHR (-5 gal vs. 72 gal median), Rheem XE50T10HS45U0 fits larger 3–5 person homes cleanly.
How do you verify manufacturing age and recall status on Rheem XE50T10HS45U0?
CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
Does Rheem XE50T10HS45U0 qualify for DOE HEAR incentives after 25C expired?
After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Rheem XE50T10HS45U0. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH50 T2 FD400-30 (3.88 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)