Rheem XE65T10HS45U0 Water Heater Specifications (4.05 UEF)
Certified at 4.05 UEF across its 59-gallon nominal tank, 75 gal First Hour Rating, Rheem XE65T10HS45U0 (Hybrid/Electric Heat Pump, Electric) places #61 of 706 out of 706 ENERGY STAR models (PD 2408576). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.55 / +62.0%. Rated annual electricity draw of 1,184 kWh/yr equates to roughly $215/yr ($2,150 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH65 T2 FD400-30 (4.05 UEF).
- Uniform Energy Factor
- 4.05 UEF
- Cohort UEF Rank
- #61 of 706 (top 14.2%)
- First Hour Rating
- 75 gal
- Storage Volume
- 59 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.55 / +62.0%

Tested at 4.05 UEF, Rheem XE65T10HS45U0 places #61 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (+0.35 UEF vs. 3.70 UEF median).
Rheem XE65T10HS45U0 clears 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.55 UEF (+62.0% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 1,184 kWh/yr for Rheem XE65T10HS45U0 runs ~$215/yr vs. ~$946/yr for a 0.92 UEF electric tank.
State electric sensitivity for Rheem XE65T10HS45U0: 10-year operating spend spans $1,732 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,586 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Closest alternatives to Rheem XE65T10HS45U0 include Friedrich PROH65 T2 FD400-30 (4.05 UEF, at parity) alongside Richmond 10CE65-HP5S30 (4.05 UEF, at parity).
Which Specs Set Rheem XE65T10HS45U0 Apart From Cohort Averages?
Ranked #61 of 706 (top 14.2%) inside the 706-model Hybrid/Electric Heat Pump cohort, Rheem XE65T10HS45U0 is evaluated row by row below against category medians.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Rheem | 236 certified listings | ENERGY STAR PD 2408576 |
| Model Number | XE65T10HS45U0 | Draw pattern: High-Usage | XE65T10HS45U0 |
| Uniform Energy Factor (UEF) | 4.05 | +0.35 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 75 gal | +3 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,184 kWh/yr | +112 kWh/yr vs. 1,072 kWh/yr median | Est. $215/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 457% | +28.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 64.2" H x 24.3" D | Verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: United States |
How Do Regional kWh Prices Impact XE65T10HS45U0 Over 10 Years?
Using EIA Table 5.6.A benchmarks, Rheem XE65T10HS45U0's 1,184 kWh/yr draw translates to roughly $215/yr on typical US residential bills.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $215/yr | $2,150 | $7,315 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $559/yr | $5,586 | $19,004 |
| California | 29.75 ¢/kWh ($0.2975) | $352/yr | $3,522 | $11,983 |
| Texas | 15.91 ¢/kWh ($0.1591) | $188/yr | $1,884 | $6,409 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $173/yr | $1,732 | $5,893 |
What Should Rheem Owners Check in CPSC Recall Logs?
The 2026-11-23 CPSC SaferProducts snapshot includes 4 filings tied to Rheem; verify whether your XE65T10HS45U0 production run falls inside affected ranges. See Serial Number Lookup.
- Recall #16177 (2016-05-26): Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot (CPSC Notice)
- Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
- Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?
Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Friedrich PROH65 T2 FD400-30 | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 4.05 (at parity) | 1,184 |
| Richmond 10CE65-HP5S30 | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 4.05 (at parity) | 1,289 |
| Ruud CPROPH65 T2 CD375-30 | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 4.05 (at parity) | 1,213 |
| Bosch TR7000T-65CA | Hybrid/Electric Heat Pump | 60 gal | 80 gal | 3.9 (-0.15) | 1,240 |
| Friedrich PROH65 T2 FD400-SO | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 4.05 (at parity) | 1,184 |
Which Home Setups Are NOT a Fit for Rheem XE65T10HS45U0?
Comparing Rheem XE65T10HS45U0 against Friedrich PROH65 T2 FD400-30 requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.
Key Limitations & Exclusions
- Rheem XE65T10HS45U0 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Rheem XE65T10HS45U0 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Frequently Asked Technical Questions: Rheem XE65T10HS45U0
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does Rheem XE65T10HS45U0 score under 10 CFR 430.32 May 2029 water heater minimums?
Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Rheem XE65T10HS45U0 logs 4.05 UEF (Pass: +1.55 / +62.0%) within the 706-unit Hybrid/Electric Heat Pump group.
What physical clearance dimensions apply when installing Rheem XE65T10HS45U0?
With a 64.2 in. height and 24.3 in. diameter, Rheem XE65T10HS45U0 fits spaces matching: verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" d), plus 6–12 in. above for plumbing shutoffs.
What 240V circuit or IFGC fuel line capacity fits Rheem XE65T10HS45U0?
Powered via 240V at 21A max, Rheem XE65T10HS45U0 requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.
How do state electricity prices change annual costs for Rheem XE65T10HS45U0?
Annual electric spend for Rheem XE65T10HS45U0 (1,184 kWh/yr) averages $215/yr nationwide (ranging from $173/yr in Washington hydro tiers up to $559/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.
What homeowner setups should avoid choosing Rheem XE65T10HS45U0?
Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Rheem XE65T10HS45U0.
Is Rheem XE65T10HS45U0 sized adequately for a 2-to-4-person household?
ENERGY STAR certifies Rheem XE65T10HS45U0 at 75 gal First Hour Rating (+3 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.
Does Rheem have active CPSC SaferProducts notices affecting XE65T10HS45U0?
CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
Which competing water heater matches Rheem XE65T10HS45U0 (4.05 UEF) most closely?
State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Rheem XE65T10HS45U0. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH65 T2 FD400-30 (4.05 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)