Rheem XE65T10HS45U1 Water Heater Specifications (4.05 UEF)
In the 706-unit Hybrid/Electric Heat Pump class, Rheem XE65T10HS45U1 (Electric) achieves a certified 4.05 UEF rating across its 59-gallon nominal tank, 75 gal First Hour Rating (rank #61 of 706, PD 3554224) and verifies as Pass: +1.55 / +62.0% for 2029 DOE floors. Rated annual electricity draw of 1,184 kWh/yr equates to roughly $215/yr ($2,150 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH65 T2 FD400-30 (4.05 UEF).
- Uniform Energy Factor
- 4.05 UEF
- Cohort UEF Rank
- #61 of 706 (top 14.2%)
- First Hour Rating
- 75 gal
- Storage Volume
- 59 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.55 / +62.0%

Rheem XE65T10HS45U1 records 4.05 UEF efficiency, putting it #61 of 706 among 706 Hybrid/Electric Heat Pump peers.
10 CFR 430.32(d)(2) compliance: Rheem XE65T10HS45U1 exceeds 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.55 UEF (+62.0%). At EIA August 2026 national rates (18.16 cents/kWh), 1,184 kWh/yr for Rheem XE65T10HS45U1 runs ~$215/yr vs. ~$946/yr for a 0.92 UEF electric tank.
State electric sensitivity for Rheem XE65T10HS45U1: 10-year operating spend spans $1,732 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,586 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Competing options beside Rheem XE65T10HS45U1 (4.05 UEF) are Friedrich PROH65 T2 FD400-30 (4.05 UEF, at parity) and Richmond 10CE65-HP5S30 (4.05 UEF, at parity).
How Complete Are the Certified Metrics for Rheem XE65T10HS45U1?
Standing at #61 of 706 (top 14.2%) among 706 certified Hybrid/Electric Heat Pump heaters, Rheem XE65T10HS45U1 brings measurable deltas in recovery, footprint, and energy efficiency.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Rheem | 236 certified listings | ENERGY STAR PD 3554224 |
| Model Number | XE65T10HS45U1 | Draw pattern: High-Usage | XE65T10HS45U1 |
| Uniform Energy Factor (UEF) | 4.05 | +0.35 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 75 gal | +3 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,184 kWh/yr | +112 kWh/yr vs. 1,072 kWh/yr median | Est. $215/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 457% | +28.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 64.2" H x 24.3" D | Verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: United States |
What Is the Projected Utility Bill for XE65T10HS45U1 by State?
At 1,184 kWh/yr, Rheem XE65T10HS45U1 averages about $215/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $215/yr | $2,150 | $7,315 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $559/yr | $5,586 | $19,004 |
| California | 29.75 ¢/kWh ($0.2975) | $352/yr | $3,522 | $11,983 |
| Texas | 15.91 ¢/kWh ($0.1591) | $188/yr | $1,884 | $6,409 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $173/yr | $1,732 | $5,893 |
Are Rheem Models Affected by Current CPSC Notices?
Review 4 brand-matched CPSC entries pulled 2026-11-23 for Rheem and confirm your serial tag before scheduling contractor service. See Serial Number Lookup.
- Recall #16177 (2016-05-26): Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot (CPSC Notice)
- Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
- Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
Which 5 Models Offer Similar Output to XE65T10HS45U1?
Ordered by minimal capacity and UEF spread relative to Rheem XE65T10HS45U1, these five certified peers give direct replacement benchmarks.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Friedrich PROH65 T2 FD400-30 | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 4.05 (at parity) | 1,184 |
| Richmond 10CE65-HP5S30 | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 4.05 (at parity) | 1,289 |
| Ruud CPROPH65 T2 CD375-30 | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 4.05 (at parity) | 1,213 |
| Bosch TR7000T-65CA | Hybrid/Electric Heat Pump | 60 gal | 80 gal | 3.9 (-0.15) | 1,240 |
| Friedrich PROH65 T2 FD400-SO | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 4.05 (at parity) | 1,184 |
Who Is Rheem XE65T10HS45U1 Best For — and When Should You Pick Friedrich PROH65 T2 FD400-30?
Evaluate whether Rheem XE65T10HS45U1's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.
Key Limitations & Exclusions
- Rheem XE65T10HS45U1 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Rheem XE65T10HS45U1 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Practical Specs & Code Questions for Rheem XE65T10HS45U1
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does Rheem XE65T10HS45U1 (4.05 UEF) compare to 2029 federal DOE floors?
Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Rheem XE65T10HS45U1 records 4.05 UEF (Pass: +1.55 / +62.0%), placing #61 of 706 (top 14.2%) out of 706 certified Hybrid/Electric Heat Pump configurations.
Does Rheem XE65T10HS45U1 fit inside a tight hallway closet or low-headroom utility room?
Rheem XE65T10HS45U1 requires room for its 64.2 in. vertical shell and 24.3 in. diameter (verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" d)), plus service access for annual sediment draining.
What power supply or fuel line specs govern Rheem XE65T10HS45U1?
For Rheem XE65T10HS45U1, plan a 240V circuit at 21A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.
What annual utility bill should homeowners budget for Rheem XE65T10HS45U1?
Using 1,184 kWh/yr, Rheem XE65T10HS45U1 generates an estimated $215/yr electric bill at 18.16 cents/kWh (ranging from $173/yr in Washington hydro tiers up to $559/yr in Hawaii)—use the custom rate slider above for your utility tariff.
What are the main drawbacks of Rheem XE65T10HS45U1 (4.05 UEF)?
Rheem XE65T10HS45U1 requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or Friedrich PROH65 T2 FD400-30.
What hot-water delivery rating governs Rheem XE65T10HS45U1?
Rated for 75 gal FHR (+3 gal vs. 72 gal median), Rheem XE65T10HS45U1 prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.
Where do homeowners screen Rheem XE65T10HS45U1 for recalls and tank age?
CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
What alternative models sit closest to Rheem XE65T10HS45U1 in the Hybrid/Electric Heat Pump class?
Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH65 T2 FD400-30 (4.05 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)