Richmond 10E80-HP5U15 Water Heater Specifications (3.7 UEF)
With PD 3554233 certification, Richmond 10E80-HP5U15 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.7 UEF rating across its 72-gallon nominal tank, 67 gal First Hour Rating, standing #347 of 706 across 706 peers with Pass: +1.20 / +48.0% for May 6, 2029. Rated annual electricity draw of 871 kWh/yr equates to roughly $158/yr ($1,582 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH80 T2 FD400-15 (3.7 UEF).
- Uniform Energy Factor
- 3.7 UEF
- Cohort UEF Rank
- #347 of 706
- First Hour Rating
- 67 gal
- Storage Volume
- 72 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.20 / +48.0%

ENERGY STAR certification places Richmond 10E80-HP5U15 at 3.7 UEF (#347 of 706; At 3.70 UEF median) in Hybrid/Electric Heat Pump.
May 6, 2029 readiness: Richmond 10E80-HP5U15 stands +1.20 UEF (+48.0%) relative to 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 871 kWh/yr for Richmond 10E80-HP5U15 runs ~$158/yr vs. ~$636/yr for a 0.92 UEF electric tank.
State electric sensitivity for Richmond 10E80-HP5U15: 10-year operating spend spans $1,274 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,109 in Hawaii (Highest EIA State) (47.18 cents/kWh).
In the Hybrid/Electric Heat Pump tier, Friedrich PROH80 T2 FD400-15 (3.7 UEF, at parity) and Rheem CPROPH80 T2 RH375-15 (3.7 UEF, at parity) bracket Richmond 10E80-HP5U15.
Which Specs Set Richmond 10E80-HP5U15 Apart From Cohort Averages?
Ranked #347 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, Richmond 10E80-HP5U15 is evaluated row by row below against category medians.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Richmond | 80 certified listings | ENERGY STAR PD 3554233 |
| Model Number | 10E80-HP5U15 | Draw pattern: Medium-Usage | 10E80-HP5U15 |
| Uniform Energy Factor (UEF) | 3.7 | At 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 67 gal | -5 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 871 kWh/yr | -201 kWh/yr vs. 1,072 kWh/yr median | Est. $158/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 445% | +16.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 74.2" H x 24.3" D | Needs >72 in. overhead clearance; clears 28 in. utility doorway (24.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 12 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: United States |
How Do Regional kWh Prices Impact 10E80-HP5U15 Over 10 Years?
Using EIA Table 5.6.A benchmarks, Richmond 10E80-HP5U15's 871 kWh/yr draw translates to roughly $158/yr on typical US residential bills.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $158/yr | $1,582 | $4,780 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $411/yr | $4,109 | $12,418 |
| California | 29.75 ¢/kWh ($0.2975) | $259/yr | $2,591 | $7,830 |
| Texas | 15.91 ¢/kWh ($0.1591) | $139/yr | $1,386 | $4,188 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $127/yr | $1,274 | $3,851 |
What Should Richmond Owners Check in CPSC Recall Logs?
The 2026-11-23 CPSC recall sweep recorded zero brand matches for Richmond; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.
How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?
Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Friedrich PROH80 T2 FD400-15 | Hybrid/Electric Heat Pump | 72 gal | 67 gal | 3.7 (at parity) | 871 |
| Rheem CPROPH80 T2 RH375-15 | Hybrid/Electric Heat Pump | 72 gal | 67 gal | 3.7 (at parity) | 871 |
| Ruud PROUH80 T2 CD400-15 | Hybrid/Electric Heat Pump | 72 gal | 67 gal | 3.7 (at parity) | 871 |
| LG APHWC801D | Hybrid/Electric Heat Pump | 72 gal | 94 gal | 3.9 (+0.20) | 1,272 |
| Rheem CPROPH80 T2 RH400-15 | Hybrid/Electric Heat Pump | 72 gal | 67 gal | 3.7 (at parity) | 871 |
When Should Homeowners Skip Richmond 10E80-HP5U15 (Hybrid/Electric Heat Pump)?
Check Richmond 10E80-HP5U15's mechanical constraints—including utility space, Electric capacity, and Pass: +1.20 / +48.0% status—against typical residential installations.
Key Limitations & Exclusions
- Richmond 10E80-HP5U15 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Richmond 10E80-HP5U15 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Frequently Asked Technical Questions: Richmond 10E80-HP5U15
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Will Richmond 10E80-HP5U15 stay compliant after the May 6, 2029 DOE standard takes effect?
Tested at 3.7 UEF, Richmond 10E80-HP5U15 shows Pass: +1.20 / +48.0% relative to May 6, 2029 federal DOE limits while placing #347 of 706 among 706 Hybrid/Electric Heat Pump peers like Friedrich PROH80 T2 FD400-15.
Will Richmond 10E80-HP5U15 fit through a standard utility door and 72-inch basement ceiling?
Measuring 74.2 in. tall by 24.3 in. diameter, Richmond 10E80-HP5U15 notes: needs >72 in. overhead clearance; clears 28 in. utility doorway (24.3" d). Reserve space above the jacket for T&P piping and anode removal.
Do existing utility hookups support Richmond 10E80-HP5U15 during replacement?
Electrical specs for Richmond 10E80-HP5U15 call for 240V at 12A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.
What is the estimated 10-year operating spend for Richmond 10E80-HP5U15?
At 18.16 cents/kWh national residential pricing, Richmond 10E80-HP5U15's 871 kWh/yr draw equals roughly $158 annually or $1,580 across a 10-year horizon (ranging from $127/yr in Washington hydro tiers up to $411/yr in Hawaii).
When is Richmond 10E80-HP5U15 a poor fit for a residential replacement?
Avoid placing Richmond 10E80-HP5U15 directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.
What First Hour Rating or flow capacity does Richmond 10E80-HP5U15 deliver?
With 67 gal FHR (-5 gal vs. 72 gal median), Richmond 10E80-HP5U15 fits larger 3–5 person homes cleanly.
How do you verify manufacturing age and recall status on Richmond 10E80-HP5U15?
Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Richmond; verify exact manufacturing week for Richmond 10E80-HP5U15 using the Serial Number Lookup tool.
Does Richmond 10E80-HP5U15 qualify for DOE HEAR incentives after 25C expired?
After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Richmond 10E80-HP5U15. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH80 T2 FD400-15 (3.7 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)