Skip to main content
ENERGY STAR water heater model · PD 3722797

Rinnai REHP65 Water Heater Specifications (3.9 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, Rinnai REHP65 achieves a certified 3.9 UEF rating across its 60-gallon nominal tank, 80 gal First Hour Rating and ranks #144 of 706 in its 706-model cohort (PD 3722797), recording Pass: +1.40 / +56.0% under 2029 DOE rules. Rated annual electricity draw of 1,240 kWh/yr equates to roughly $225/yr ($2,252 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Bosch TR7000T-65CA (3.9 UEF).

Uniform Energy Factor
3.9 UEF
Cohort UEF Rank
#144 of 706 (top 22.9%)
First Hour Rating
80 gal
Storage Volume
60 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.40 / +56.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Rinnai REHP65 at 3.9 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Rinnai REHP65: 3.90
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Rinnai REHP65 relative to the cohort median.
Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, Rinnai REHP65 logs 3.9 UEF and ranks #144 of 706.

Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), Rinnai REHP65 holds a +1.40 UEF (+56.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,240 kWh/yr for Rinnai REHP65 runs ~$225/yr vs. ~$955/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).

State electric sensitivity for Rinnai REHP65: 10-year operating spend spans $1,814 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,850 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping Rinnai REHP65 (3.9 UEF)? Check Bosch TR7000T-65CA (3.9 UEF, at parity) and Custom Comfort CCOHPWH65A (3.9 UEF, at parity).

What Physical and Thermal Ratings Define Rinnai REHP65?

Positioning at #144 of 706 (top 22.9%) out of 706 Hybrid/Electric Heat Pump peers, Rinnai REHP65 pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRinnai25 certified listingsENERGY STAR PD 3722797
Model NumberREHP65Draw pattern: High-UsageREHP65
Uniform Energy Factor (UEF)3.9+0.20 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)80 gal+8 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,240 kWh/yr+168 kWh/yr vs. 1,072 kWh/yr medianEst. $225/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency450%+21.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)45.5" H x 21.8" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 24 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Sound Pressure Level49 dBAquieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA medianIndoor placement check
Certification Date2026-03-17Certified 2026-03-17Markets: United States, Canada

Why Do State Utility Rates Shift REHP65 Running Costs?

Consuming 1,240 kWh annually puts Rinnai REHP65 near $225/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Estimated Annual Electricity Cost by State Rate (1,240 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$225.00/yrHawaii$585.00/yrCalifornia$369.00/yrTexas$197.00/yrWashington$181.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $225/yr $2,252 $7,295
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $585/yr $5,850 $18,952
California 29.75 ¢/kWh ($0.2975) $369/yr $3,689 $11,951
Texas 15.91 ¢/kWh ($0.1591) $197/yr $1,973 $6,391
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $181/yr $1,814 $5,877
Estimated electricity spend (1,240 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any Rinnai Series Triggered CPSC Recalls?

SaferProducts screening on 2026-11-23 returned zero recall matches for Rinnai; confirm tank age separately using the rating-plate serial pattern. See Serial Number Lookup.

What Are 5 Direct Alternatives to Rinnai REHP65?

Homeowners cross-shopping Rinnai REHP65 frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Bosch TR7000T-65CA Hybrid/Electric Heat Pump 60 gal 80 gal 3.9 (at parity) 1,240
Custom Comfort CCOHPWH65A Hybrid/Electric Heat Pump 60 gal 80 gal 3.9 (at parity) 1,240
Eco-Logical ECO-65HPM1A Hybrid/Electric Heat Pump 60 gal 80 gal 3.9 (at parity) 1,240
Kepler AZMCHW-65VN3A Hybrid/Electric Heat Pump 60 gal 80 gal 3.9 (at parity) 1,240
Bosch TR7000T-65US Hybrid/Electric Heat Pump 60 gal 80 gal 3.9 (at parity) 1,240

Who Is Rinnai REHP65 Best For — and When Should You Pick Bosch TR7000T-65CA?

Evaluate whether Rinnai REHP65's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

Key Limitations & Exclusions

  • Rinnai REHP65 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Rinnai REHP65 directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Rinnai REHP65 Strong Fit — 3.9 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Bosch TR7000T-65CA footprint.

Sizing, Efficiency & Recall Answers for Rinnai REHP65

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Rinnai REHP65 (3.9 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Rinnai REHP65 records 3.9 UEF (Pass: +1.40 / +56.0%), placing #144 of 706 (top 22.9%) out of 706 certified Hybrid/Electric Heat Pump configurations.

Does Rinnai REHP65 fit inside a tight hallway closet or low-headroom utility room?

Rinnai REHP65 requires room for its 45.5 in. vertical shell and 21.8 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d)), plus service access for annual sediment draining.

What power supply or fuel line specs govern Rinnai REHP65?

For Rinnai REHP65, plan a 240V circuit at 24A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.

What annual utility bill should homeowners budget for Rinnai REHP65?

Using 1,240 kWh/yr, Rinnai REHP65 generates an estimated $225/yr electric bill at 18.16 cents/kWh (ranging from $181/yr in Washington hydro tiers up to $585/yr in Hawaii)—use the custom rate slider above for your utility tariff.

What are the main drawbacks of Rinnai REHP65 (3.9 UEF)?

Rinnai REHP65 requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or Bosch TR7000T-65CA.

What hot-water delivery rating governs Rinnai REHP65?

Rated for 80 gal FHR (+8 gal vs. 72 gal median), Rinnai REHP65 prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

Where do homeowners screen Rinnai REHP65 for recalls and tank age?

Verified clean against 2026-11-23 CPSC recall feeds for Rinnai; use our browser-only serial decoder to inspect Rinnai REHP65's age and warranty window.

What alternative models sit closest to Rinnai REHP65 in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is Bosch TR7000T-65CA (3.9 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks