Ruud PRO H40 T2 RU310UM Water Heater Specifications (3.5 UEF)
With PD 2408558 certification, Ruud PRO H40 T2 RU310UM (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.5 UEF rating across its 36-gallon nominal tank, 60 gal First Hour Rating, standing #481 of 706 across 706 peers with Pass: +1.20 / +52.2% for May 6, 2029. Rated annual electricity draw of 879 kWh/yr equates to roughly $160/yr ($1,596 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH40 T2 FD310BM (3.5 UEF).
- Uniform Energy Factor
- 3.5 UEF
- Cohort UEF Rank
- #481 of 706
- First Hour Rating
- 60 gal
- Storage Volume
- 36 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.20 / +52.2%

ENERGY STAR certification places Ruud PRO H40 T2 RU310UM at 3.5 UEF (#481 of 706; -0.20 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.
May 6, 2029 readiness: Ruud PRO H40 T2 RU310UM stands +1.20 UEF (+52.2%) relative to 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 879 kWh/yr for Ruud PRO H40 T2 RU310UM runs ~$160/yr vs. ~$607/yr for a 0.92 UEF electric tank.
State electric sensitivity for Ruud PRO H40 T2 RU310UM: 10-year operating spend spans $1,286 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,147 in Hawaii (Highest EIA State) (47.18 cents/kWh).
In the Hybrid/Electric Heat Pump tier, Friedrich PROH40 T2 FD310BM (3.5 UEF, at parity) and Rheem CPROPH40 T2 RH350BM (3.5 UEF, at parity) bracket Ruud PRO H40 T2 RU310UM.
Which Specs Set Ruud PRO H40 T2 RU310UM Apart From Cohort Averages?
Ranked #481 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, Ruud PRO H40 T2 RU310UM is evaluated row by row below against category medians.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Ruud | 95 certified listings | ENERGY STAR PD 2408558 |
| Model Number | PRO H40 T2 RU310UM | Draw pattern: Medium-Usage | PRO H40 T2 RU310UM |
| Uniform Energy Factor (UEF) | 3.5 | -0.20 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 60 gal | -12 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 879 kWh/yr | -193 kWh/yr vs. 1,072 kWh/yr median | Est. $160/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 430% | +1.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 62.3" H x 20.3" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: United States |
How Do Regional kWh Prices Impact PRO H40 T2 RU310UM Over 10 Years?
Using EIA Table 5.6.A benchmarks, Ruud PRO H40 T2 RU310UM's 879 kWh/yr draw translates to roughly $160/yr on typical US residential bills.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $160/yr | $1,596 | $4,476 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $415/yr | $4,147 | $11,630 |
| California | 29.75 ¢/kWh ($0.2975) | $262/yr | $2,615 | $7,333 |
| Texas | 15.91 ¢/kWh ($0.1591) | $140/yr | $1,398 | $3,922 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $129/yr | $1,286 | $3,606 |
What Should Ruud Owners Check in CPSC Recall Logs?
The 2026-11-23 CPSC SaferProducts snapshot includes 2 filings tied to Ruud; verify whether your PRO H40 T2 RU310UM production run falls inside affected ranges. See Serial Number Lookup.
- Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
- Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?
Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Friedrich PROH40 T2 FD310BM | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.5 (at parity) | 879 |
| Rheem CPROPH40 T2 RH350BM | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.5 (at parity) | 879 |
| Richmond 10CE40-HP5U15 | Hybrid/Electric Heat Pump | 36 gal | 46 gal | 3.45 (-0.05) | 643 |
| A. O. Smith CAHP-40 2** | Hybrid/Electric Heat Pump | 36 gal | 55 gal | 3.6 (+0.10) | 902 |
| Friedrich PROH40 T2 FD310UM | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.5 (at parity) | 879 |
What Installation Caveats Apply Before Buying Ruud PRO H40 T2 RU310UM?
Even high-UEF units like Ruud PRO H40 T2 RU310UM (3.5 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.
Key Limitations & Exclusions
- Ruud PRO H40 T2 RU310UM needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Ruud PRO H40 T2 RU310UM directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Frequently Asked Technical Questions: Ruud PRO H40 T2 RU310UM
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Is Ruud PRO H40 T2 RU310UM eligible for continued manufacture past May 6, 2029?
At 3.5 UEF, Ruud PRO H40 T2 RU310UM achieves Pass: +1.20 / +52.2% for the 2029 DOE standard and stands #481 of 706 against Friedrich PROH40 T2 FD310BM and Rheem CPROPH40 T2 RH350BM.
How tall and wide is Ruud PRO H40 T2 RU310UM, and what service clearance is needed?
Physical dimensions for Ruud PRO H40 T2 RU310UM are 62.3 in. height and 20.3 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" d)); verify stair turns and drain pan width before delivery.
Will Ruud PRO H40 T2 RU310UM require upgrading household electrical panels or gas piping?
Ruud PRO H40 T2 RU310UM draws 240V at 21A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.
Is Ruud PRO H40 T2 RU310UM economical to operate at 18.16 cents/kWh US electric rates?
Expect roughly $160/yr ($1,600 over 10 years) to power Ruud PRO H40 T2 RU310UM at 879 kWh/yr under the 18.16 cents/kWh US average (ranging from $129/yr in Washington hydro tiers up to $415/yr in Hawaii).
Which installation bottlenecks limit Ruud PRO H40 T2 RU310UM?
If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, Ruud PRO H40 T2 RU310UM drops into resistance mode more often.
How does Ruud PRO H40 T2 RU310UM handle simultaneous showers and laundry?
Delivering 60 gal in the first hour (-12 gal vs. 72 gal median), Ruud PRO H40 T2 RU310UM combines 36 gal tank storage with rapid burner/element recovery.
How long is the warranty on Ruud PRO H40 T2 RU310UM and how do you decode its serial?
CPSC SaferProducts records show 2 brand-level recall notices mentioning Ruud as of 2026-11-23, including #07108 (2007-02-21). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
How do 2026 post-OBBBA rebates affect buying Ruud PRO H40 T2 RU310UM?
Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH40 T2 FD310BM (3.5 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)