Skip to main content
ENERGY STAR water heater model · PD 2408556

Ruud PRO H50 T2 RU310UM Water Heater Specifications (3.5 UEF)

Certified at 3.5 UEF across its 45-gallon nominal tank, 67 gal First Hour Rating, Ruud PRO H50 T2 RU310UM (Hybrid/Electric Heat Pump, Electric) places #481 of 706 out of 706 ENERGY STAR models (PD 2408556). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.20 / +52.2%. Rated annual electricity draw of 915 kWh/yr equates to roughly $166/yr ($1,662 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH50 T2 FD310BM (3.5 UEF).

Uniform Energy Factor
3.5 UEF
Cohort UEF Rank
#481 of 706
First Hour Rating
67 gal
Storage Volume
45 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.20 / +52.2%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Ruud PRO H50 T2 RU310UM at 3.5 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Ruud PRO H50 T2 RU310UM: 3.50
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Ruud PRO H50 T2 RU310UM relative to the cohort median.
Efficiency comparison & rule summary

Tested at 3.5 UEF, Ruud PRO H50 T2 RU310UM places #481 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (-0.20 UEF vs. 3.70 UEF median).

Ruud PRO H50 T2 RU310UM clears 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.20 UEF (+52.2% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 915 kWh/yr for Ruud PRO H50 T2 RU310UM runs ~$166/yr vs. ~$632/yr for a 0.92 UEF electric tank.

State electric sensitivity for Ruud PRO H50 T2 RU310UM: 10-year operating spend spans $1,339 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,317 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to Ruud PRO H50 T2 RU310UM include Friedrich PROH50 T2 FD310BM (3.5 UEF, at parity) alongside Rheem CPROPH50 T2 RH350BM (3.5 UEF, at parity).

How Do Ruud PRO H50 T2 RU310UM Specs Compare to Hybrid/Electric Heat Pump Medians?

Ruud PRO H50 T2 RU310UM places #481 of 706 across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRuud95 certified listingsENERGY STAR PD 2408556
Model NumberPRO H50 T2 RU310UMDraw pattern: Medium-UsagePRO H50 T2 RU310UM
Uniform Energy Factor (UEF)3.5-0.20 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)67 gal-5 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use915 kWh/yr-157 kWh/yr vs. 1,072 kWh/yr medianEst. $166/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency400%-29.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)61.8" H x 22.3" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 21 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-10-15Certified 2026-10-15Markets: United States

What Does PRO H50 T2 RU310UM Cost to Operate Across State Electricity Rates?

At 915 kWh/yr, Ruud PRO H50 T2 RU310UM runs roughly $166/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Estimated Annual Electricity Cost by State Rate (915 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$166.00/yrHawaii$432.00/yrCalifornia$272.00/yrTexas$146.00/yrWashington$134.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $166/yr $1,662 $4,660
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $432/yr $4,317 $12,106
California 29.75 ¢/kWh ($0.2975) $272/yr $2,722 $7,634
Texas 15.91 ¢/kWh ($0.1591) $146/yr $1,456 $4,083
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $134/yr $1,339 $3,754
Estimated electricity spend (915 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for Ruud Water Heaters?

Our 2026-11-23 CPSC SaferProducts query surfaced 2 brand-level recall notices associated with Ruud; match your serial plate before repair. See Serial Number Lookup.

2 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
  • Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)

Which Certified Water Heaters Match PRO H50 T2 RU310UM Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to Ruud PRO H50 T2 RU310UM by storage capacity and 3.5 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH50 T2 FD310BM Hybrid/Electric Heat Pump 45 gal 67 gal 3.5 (at parity) 915
Rheem CPROPH50 T2 RH350BM Hybrid/Electric Heat Pump 45 gal 67 gal 3.5 (at parity) 915
A. O. Smith HPACO-45 1**+AXST-50T 1** Hybrid/Electric Heat Pump 45 gal 67 gal 3.52 (+0.02) 923
American MHPCO-45 1**+MXST-50T 1** Hybrid/Electric Heat Pump 45 gal 67 gal 3.52 (+0.02) 923
Friedrich PROH50 T2 FD310UM Hybrid/Electric Heat Pump 45 gal 67 gal 3.5 (at parity) 915

What Are the Limitations of Ruud PRO H50 T2 RU310UM and Who Should Not Install It?

Before ordering Ruud PRO H50 T2 RU310UM (Hybrid/Electric Heat Pump, 3.5 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

Key Limitations & Exclusions

  • Ruud PRO H50 T2 RU310UM needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Ruud PRO H50 T2 RU310UM directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Ruud PRO H50 T2 RU310UM Strong Fit — 3.5 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH50 T2 FD310BM footprint.

What Are the Key Questions About Ruud PRO H50 T2 RU310UM?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does Ruud PRO H50 T2 RU310UM pass the May 6, 2029 federal DOE efficiency rule?

Ruud PRO H50 T2 RU310UM carries a verified 3.5 UEF rating (Pass: +1.20 / +52.2%), ranking #481 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

What doorway width and ceiling height does Ruud PRO H50 T2 RU310UM need?

Ruud PRO H50 T2 RU310UM stands 61.8 in. high with a 22.3 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

What gas pipe size or electrical breaker does Ruud PRO H50 T2 RU310UM require?

Ruud PRO H50 T2 RU310UM uses a 240V branch circuit at 21A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

How much electricity or energy does Ruud PRO H50 T2 RU310UM cost per year to run?

Rated at 915 kWh/yr, Ruud PRO H50 T2 RU310UM costs about $166/yr ($1,660 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $134/yr in Washington hydro tiers up to $432/yr in Hawaii).

Who should NOT install Ruud PRO H50 T2 RU310UM, and what are its limits?

Ruud PRO H50 T2 RU310UM (3.5 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.

How many bathrooms or people can Ruud PRO H50 T2 RU310UM serve at peak demand?

Ruud PRO H50 T2 RU310UM achieves a 67 gal First Hour Rating (-5 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

Are there CPSC safety recalls or serial checks for Ruud PRO H50 T2 RU310UM?

CPSC SaferProducts records show 2 brand-level recall notices mentioning Ruud as of 2026-11-23, including #07108 (2007-02-21). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

What 2026 rebates apply to Ruud PRO H50 T2 RU310UM, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH50 T2 FD310BM (3.5 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks