Ruud PRO H65 T2 RU310UM Water Heater Specifications (3.5 UEF)
Certified at 3.5 UEF across its 59-gallon nominal tank, 75 gal First Hour Rating, Ruud PRO H65 T2 RU310UM (Hybrid/Electric Heat Pump, Electric) places #481 of 706 out of 706 ENERGY STAR models (PD 2408596). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.00 / +40.0%. Rated annual electricity draw of 900 kWh/yr equates to roughly $163/yr ($1,634 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH65 T2 FD310BM (3.5 UEF).
- Uniform Energy Factor
- 3.5 UEF
- Cohort UEF Rank
- #481 of 706
- First Hour Rating
- 75 gal
- Storage Volume
- 59 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.00 / +40.0%

Tested at 3.5 UEF, Ruud PRO H65 T2 RU310UM places #481 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (-0.20 UEF vs. 3.70 UEF median).
Ruud PRO H65 T2 RU310UM clears 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.00 UEF (+40.0% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 900 kWh/yr for Ruud PRO H65 T2 RU310UM runs ~$163/yr vs. ~$622/yr for a 0.92 UEF electric tank.
State electric sensitivity for Ruud PRO H65 T2 RU310UM: 10-year operating spend spans $1,317 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,246 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Closest alternatives to Ruud PRO H65 T2 RU310UM include Friedrich PROH65 T2 FD310BM (3.5 UEF, at parity) alongside Rheem CPRO H65 T2 RH310BM (3.5 UEF, at parity).
What Physical and Thermal Ratings Define Ruud PRO H65 T2 RU310UM?
Positioning at #481 of 706 out of 706 Hybrid/Electric Heat Pump peers, Ruud PRO H65 T2 RU310UM pairs measured UEF performance with specific clearance and wiring rules.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Ruud | 95 certified listings | ENERGY STAR PD 2408596 |
| Model Number | PRO H65 T2 RU310UM | Draw pattern: High-Usage | PRO H65 T2 RU310UM |
| Uniform Energy Factor (UEF) | 3.5 | -0.20 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 75 gal | +3 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 900 kWh/yr | -172 kWh/yr vs. 1,072 kWh/yr median | Est. $163/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 409% | -20.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 64.2" H x 24.3" D | Verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: United States |
Why Do State Utility Rates Shift PRO H65 T2 RU310UM Running Costs?
Consuming 900 kWh annually puts Ruud PRO H65 T2 RU310UM near $163/yr at US baseline tariffs, with multi-state EIA comparisons charted below.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $163/yr | $1,634 | $4,584 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $425/yr | $4,246 | $11,908 |
| California | 29.75 ¢/kWh ($0.2975) | $268/yr | $2,678 | $7,509 |
| Texas | 15.91 ¢/kWh ($0.1591) | $143/yr | $1,432 | $4,016 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $132/yr | $1,317 | $3,693 |
Have Any Ruud Series Triggered CPSC Recalls?
SaferProducts records retrieved 2026-11-23 list 2 brand notices under Ruud; inspect model coverage dates prior to valve or anode service. See Serial Number Lookup.
- Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
- Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
What Are 5 Direct Alternatives to Ruud PRO H65 T2 RU310UM?
Homeowners cross-shopping Ruud PRO H65 T2 RU310UM frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Friedrich PROH65 T2 FD310BM | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 3.5 (at parity) | 900 |
| Rheem CPRO H65 T2 RH310BM | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 3.5 (at parity) | 900 |
| Richmond 10CE65-HP5U15 | Hybrid/Electric Heat Pump | 59 gal | 54 gal | 3.55 (+0.05) | 887 |
| A. O. Smith HPACO-45 1**+AXST-66 1** | Hybrid/Electric Heat Pump | 60 gal | 82 gal | 3.7 (+0.20) | 1,341 |
| Friedrich PROH65 T2 FD310UM | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 3.5 (at parity) | 900 |
What Installation Caveats Apply Before Buying Ruud PRO H65 T2 RU310UM?
Even high-UEF units like Ruud PRO H65 T2 RU310UM (3.5 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.
Key Limitations & Exclusions
- Ruud PRO H65 T2 RU310UM needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Ruud PRO H65 T2 RU310UM directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Sizing, Efficiency & Recall Answers for Ruud PRO H65 T2 RU310UM
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Is Ruud PRO H65 T2 RU310UM eligible for continued manufacture past May 6, 2029?
At 3.5 UEF, Ruud PRO H65 T2 RU310UM achieves Pass: +1.00 / +40.0% for the 2029 DOE standard and stands #481 of 706 against Friedrich PROH65 T2 FD310BM and Rheem CPRO H65 T2 RH310BM.
How tall and wide is Ruud PRO H65 T2 RU310UM, and what service clearance is needed?
Physical dimensions for Ruud PRO H65 T2 RU310UM are 64.2 in. height and 24.3 in. diameter (verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" d)); verify stair turns and drain pan width before delivery.
Will Ruud PRO H65 T2 RU310UM require upgrading household electrical panels or gas piping?
Ruud PRO H65 T2 RU310UM draws 240V at 21A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.
Is Ruud PRO H65 T2 RU310UM economical to operate at 18.16 cents/kWh US electric rates?
Expect roughly $163/yr ($1,630 over 10 years) to power Ruud PRO H65 T2 RU310UM at 900 kWh/yr under the 18.16 cents/kWh US average (ranging from $132/yr in Washington hydro tiers up to $425/yr in Hawaii).
Which installation bottlenecks limit Ruud PRO H65 T2 RU310UM?
If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, Ruud PRO H65 T2 RU310UM drops into resistance mode more often.
How does Ruud PRO H65 T2 RU310UM handle simultaneous showers and laundry?
Delivering 75 gal in the first hour (+3 gal vs. 72 gal median), Ruud PRO H65 T2 RU310UM combines 59 gal tank storage with rapid burner/element recovery.
How long is the warranty on Ruud PRO H65 T2 RU310UM and how do you decode its serial?
CPSC SaferProducts records show 2 brand-level recall notices mentioning Ruud as of 2026-11-23, including #07108 (2007-02-21). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
How do 2026 post-OBBBA rebates affect buying Ruud PRO H65 T2 RU310UM?
Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH65 T2 FD310BM (3.5 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)