Skip to main content
ENERGY STAR water heater model · PD 3994196

Ruud PROUH40 T2 RU350UM Water Heater Specifications (3.5 UEF)

Certified at 3.5 UEF across its 36-gallon nominal tank, 60 gal First Hour Rating, Ruud PROUH40 T2 RU350UM (Hybrid/Electric Heat Pump, Electric) places #481 of 706 out of 706 ENERGY STAR models (PD 3994196). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.20 / +52.2%. Rated annual electricity draw of 879 kWh/yr equates to roughly $160/yr ($1,596 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH40 T2 FD310BM (3.5 UEF).

Uniform Energy Factor
3.5 UEF
Cohort UEF Rank
#481 of 706
First Hour Rating
60 gal
Storage Volume
36 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.20 / +52.2%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Ruud PROUH40 T2 RU350UM at 3.5 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Ruud PROUH40 T2 RU350UM: 3.50
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Ruud PROUH40 T2 RU350UM relative to the cohort median.
Efficiency comparison & rule summary

Tested at 3.5 UEF, Ruud PROUH40 T2 RU350UM places #481 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (-0.20 UEF vs. 3.70 UEF median).

Ruud PROUH40 T2 RU350UM clears 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.20 UEF (+52.2% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 879 kWh/yr for Ruud PROUH40 T2 RU350UM runs ~$160/yr vs. ~$607/yr for a 0.92 UEF electric tank.

State electric sensitivity for Ruud PROUH40 T2 RU350UM: 10-year operating spend spans $1,286 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,147 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to Ruud PROUH40 T2 RU350UM include Friedrich PROH40 T2 FD310BM (3.5 UEF, at parity) alongside Rheem CPROPH40 T2 RH350BM (3.5 UEF, at parity).

How Complete Are the Certified Metrics for Ruud PROUH40 T2 RU350UM?

Standing at #481 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, Ruud PROUH40 T2 RU350UM brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRuud95 certified listingsENERGY STAR PD 3994196
Model NumberPROUH40 T2 RU350UMDraw pattern: Medium-UsagePROUH40 T2 RU350UM
Uniform Energy Factor (UEF)3.5-0.20 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)60 gal-12 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use879 kWh/yr-193 kWh/yr vs. 1,072 kWh/yr medianEst. $160/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency423%-6.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)62.3" H x 20.3" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 21 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-10-15Certified 2026-10-15Markets: United States

What Is the Projected Utility Bill for PROUH40 T2 RU350UM by State?

At 879 kWh/yr, Ruud PROUH40 T2 RU350UM averages about $160/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Estimated Annual Electricity Cost by State Rate (879 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$160.00/yrHawaii$415.00/yrCalifornia$262.00/yrTexas$140.00/yrWashington$129.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $160/yr $1,596 $4,476
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $415/yr $4,147 $11,630
California 29.75 ¢/kWh ($0.2975) $262/yr $2,615 $7,333
Texas 15.91 ¢/kWh ($0.1591) $140/yr $1,398 $3,922
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $129/yr $1,286 $3,606
Estimated electricity spend (879 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are Ruud Models Affected by Current CPSC Notices?

Review 2 brand-matched CPSC entries pulled 2026-11-23 for Ruud and confirm your serial tag before scheduling contractor service. See Serial Number Lookup.

2 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
  • Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)

Which 5 Models Offer Similar Output to PROUH40 T2 RU350UM?

Ordered by minimal capacity and UEF spread relative to Ruud PROUH40 T2 RU350UM, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH40 T2 FD310BM Hybrid/Electric Heat Pump 36 gal 60 gal 3.5 (at parity) 879
Rheem CPROPH40 T2 RH350BM Hybrid/Electric Heat Pump 36 gal 60 gal 3.5 (at parity) 879
Richmond 10CE40-HP5U15 Hybrid/Electric Heat Pump 36 gal 46 gal 3.45 (-0.05) 643
A. O. Smith CAHP-40 2** Hybrid/Electric Heat Pump 36 gal 55 gal 3.6 (+0.10) 902
Friedrich PROH40 T2 FD310UM Hybrid/Electric Heat Pump 36 gal 60 gal 3.5 (at parity) 879

When Should Homeowners Skip Ruud PROUH40 T2 RU350UM (Hybrid/Electric Heat Pump)?

Check Ruud PROUH40 T2 RU350UM's mechanical constraints—including utility space, Electric capacity, and Pass: +1.20 / +52.2% status—against typical residential installations.

Key Limitations & Exclusions

  • Ruud PROUH40 T2 RU350UM needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Ruud PROUH40 T2 RU350UM directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Ruud PROUH40 T2 RU350UM Strong Fit — 3.5 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH40 T2 FD310BM footprint.

Practical Specs & Code Questions for Ruud PROUH40 T2 RU350UM

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will Ruud PROUH40 T2 RU350UM stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.5 UEF, Ruud PROUH40 T2 RU350UM shows Pass: +1.20 / +52.2% relative to May 6, 2029 federal DOE limits while placing #481 of 706 among 706 Hybrid/Electric Heat Pump peers like Friedrich PROH40 T2 FD310BM.

Will Ruud PROUH40 T2 RU350UM fit through a standard utility door and 72-inch basement ceiling?

Measuring 62.3 in. tall by 20.3 in. diameter, Ruud PROUH40 T2 RU350UM notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" d). Reserve space above the jacket for T&P piping and anode removal.

Do existing utility hookups support Ruud PROUH40 T2 RU350UM during replacement?

Electrical specs for Ruud PROUH40 T2 RU350UM call for 240V at 21A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

What is the estimated 10-year operating spend for Ruud PROUH40 T2 RU350UM?

At 18.16 cents/kWh national residential pricing, Ruud PROUH40 T2 RU350UM's 879 kWh/yr draw equals roughly $160 annually or $1,600 across a 10-year horizon (ranging from $129/yr in Washington hydro tiers up to $415/yr in Hawaii).

When is Ruud PROUH40 T2 RU350UM a poor fit for a residential replacement?

Avoid placing Ruud PROUH40 T2 RU350UM directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

What First Hour Rating or flow capacity does Ruud PROUH40 T2 RU350UM deliver?

With 60 gal FHR (-12 gal vs. 72 gal median), Ruud PROUH40 T2 RU350UM fits 1–3 person or moderate-draw homes cleanly.

How do you verify manufacturing age and recall status on Ruud PROUH40 T2 RU350UM?

CPSC SaferProducts records show 2 brand-level recall notices mentioning Ruud as of 2026-11-23, including #07108 (2007-02-21). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Does Ruud PROUH40 T2 RU350UM qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Ruud PROUH40 T2 RU350UM. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH40 T2 FD310BM (3.5 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks