Skip to main content
ENERGY STAR water heater model · PD 2408516

Ruud PROUH40 T2 RU375-15 Water Heater Specifications (3.45 UEF)

Certified at 3.45 UEF across its 36-gallon nominal tank, 46 gal First Hour Rating, Ruud PROUH40 T2 RU375-15 (Hybrid/Electric Heat Pump, Electric) places #563 of 706 out of 706 ENERGY STAR models (PD 2408516). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.15 / +50.0%. Rated annual electricity draw of 643 kWh/yr equates to roughly $117/yr ($1,168 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH40 T2 FD400-15 (3.45 UEF).

Uniform Energy Factor
3.45 UEF
Cohort UEF Rank
#563 of 706
First Hour Rating
46 gal
Storage Volume
36 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.15 / +50.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Ruud PROUH40 T2 RU375-15 at 3.45 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Ruud PROUH40 T2 RU375-15: 3.45
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Ruud PROUH40 T2 RU375-15 relative to the cohort median.
Efficiency comparison & rule summary

Tested at 3.45 UEF, Ruud PROUH40 T2 RU375-15 places #563 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (-0.25 UEF vs. 3.70 UEF median).

Ruud PROUH40 T2 RU375-15 clears 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.15 UEF (+50.0% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 643 kWh/yr for Ruud PROUH40 T2 RU375-15 runs ~$117/yr vs. ~$438/yr for a 0.92 UEF electric tank.

State electric sensitivity for Ruud PROUH40 T2 RU375-15: 10-year operating spend spans $941 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,034 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to Ruud PROUH40 T2 RU375-15 include Friedrich PROH40 T2 FD400-15 (3.45 UEF, at parity) alongside Rheem CPROPH40 T2 RH400-15 (3.45 UEF, at parity).

How Do Ruud PROUH40 T2 RU375-15 Specs Compare to Hybrid/Electric Heat Pump Medians?

Ruud PROUH40 T2 RU375-15 places #563 of 706 across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRuud95 certified listingsENERGY STAR PD 2408516
Model NumberPROUH40 T2 RU375-15Draw pattern: Low-UsagePROUH40 T2 RU375-15
Uniform Energy Factor (UEF)3.45-0.25 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)46 gal-26 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use643 kWh/yr-429 kWh/yr vs. 1,072 kWh/yr medianEst. $117/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency432%+3.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)62.3" H x 20.3" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 12 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-10-15Certified 2026-10-15Markets: United States

What Does PROUH40 T2 RU375-15 Cost to Operate Across State Electricity Rates?

At 643 kWh/yr, Ruud PROUH40 T2 RU375-15 runs roughly $117/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Estimated Annual Electricity Cost by State Rate (643 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$117.00/yrHawaii$303.00/yrCalifornia$191.00/yrTexas$102.00/yrWashington$94.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $117/yr $1,168 $3,211
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $303/yr $3,034 $8,341
California 29.75 ¢/kWh ($0.2975) $191/yr $1,913 $5,260
Texas 15.91 ¢/kWh ($0.1591) $102/yr $1,023 $2,813
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $94/yr $941 $2,587
Estimated electricity spend (643 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for Ruud Water Heaters?

Our 2026-11-23 CPSC SaferProducts query surfaced 2 brand-level recall notices associated with Ruud; match your serial plate before repair. See Serial Number Lookup.

2 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
  • Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)

Which Certified Water Heaters Match PROUH40 T2 RU375-15 Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to Ruud PROUH40 T2 RU375-15 by storage capacity and 3.45 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH40 T2 FD400-15 Hybrid/Electric Heat Pump 36 gal 46 gal 3.45 (at parity) 643
Rheem CPROPH40 T2 RH400-15 Hybrid/Electric Heat Pump 36 gal 46 gal 3.45 (at parity) 643
Richmond 10CE40-HP5U15 Hybrid/Electric Heat Pump 36 gal 46 gal 3.45 (at parity) 643
A. O. Smith CAHP-40 2** Hybrid/Electric Heat Pump 36 gal 55 gal 3.6 (+0.15) 902
Rheem ECEPH40 T2 RH400-15 Hybrid/Electric Heat Pump 36 gal 46 gal 3.45 (at parity) 643

When Should Homeowners Skip Ruud PROUH40 T2 RU375-15 (Hybrid/Electric Heat Pump)?

Check Ruud PROUH40 T2 RU375-15's mechanical constraints—including utility space, Electric capacity, and Pass: +1.15 / +50.0% status—against typical residential installations.

Key Limitations & Exclusions

  • Ruud PROUH40 T2 RU375-15 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Ruud PROUH40 T2 RU375-15 directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Ruud PROUH40 T2 RU375-15 Strong Fit — 3.45 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH40 T2 FD400-15 footprint.

What Are the Key Questions About Ruud PROUH40 T2 RU375-15?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will Ruud PROUH40 T2 RU375-15 stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.45 UEF, Ruud PROUH40 T2 RU375-15 shows Pass: +1.15 / +50.0% relative to May 6, 2029 federal DOE limits while placing #563 of 706 among 706 Hybrid/Electric Heat Pump peers like Friedrich PROH40 T2 FD400-15.

Will Ruud PROUH40 T2 RU375-15 fit through a standard utility door and 72-inch basement ceiling?

Measuring 62.3 in. tall by 20.3 in. diameter, Ruud PROUH40 T2 RU375-15 notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" d). Reserve space above the jacket for T&P piping and anode removal.

Do existing utility hookups support Ruud PROUH40 T2 RU375-15 during replacement?

Electrical specs for Ruud PROUH40 T2 RU375-15 call for 240V at 12A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

What is the estimated 10-year operating spend for Ruud PROUH40 T2 RU375-15?

At 18.16 cents/kWh national residential pricing, Ruud PROUH40 T2 RU375-15's 643 kWh/yr draw equals roughly $117 annually or $1,170 across a 10-year horizon (ranging from $94/yr in Washington hydro tiers up to $303/yr in Hawaii).

When is Ruud PROUH40 T2 RU375-15 a poor fit for a residential replacement?

Avoid placing Ruud PROUH40 T2 RU375-15 directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

What First Hour Rating or flow capacity does Ruud PROUH40 T2 RU375-15 deliver?

With 46 gal FHR (-26 gal vs. 72 gal median), Ruud PROUH40 T2 RU375-15 fits 1–3 person or moderate-draw homes cleanly.

How do you verify manufacturing age and recall status on Ruud PROUH40 T2 RU375-15?

CPSC SaferProducts records show 2 brand-level recall notices mentioning Ruud as of 2026-11-23, including #07108 (2007-02-21). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Does Ruud PROUH40 T2 RU375-15 qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Ruud PROUH40 T2 RU375-15. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH40 T2 FD400-15 (3.45 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks