Skip to main content
ENERGY STAR water heater model · PD 3994187

Ruud PROUH65 T2 RU350UM Water Heater Specifications (3.5 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, Ruud PROUH65 T2 RU350UM achieves a certified 3.5 UEF rating across its 59-gallon nominal tank, 75 gal First Hour Rating and ranks #481 of 706 in its 706-model cohort (PD 3994187), recording Pass: +1.00 / +40.0% under 2029 DOE rules. Rated annual electricity draw of 900 kWh/yr equates to roughly $163/yr ($1,634 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH65 T2 FD310BM (3.5 UEF).

Uniform Energy Factor
3.5 UEF
Cohort UEF Rank
#481 of 706
First Hour Rating
75 gal
Storage Volume
59 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.00 / +40.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Ruud PROUH65 T2 RU350UM at 3.5 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Ruud PROUH65 T2 RU350UM: 3.50
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Ruud PROUH65 T2 RU350UM relative to the cohort median.
Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, Ruud PROUH65 T2 RU350UM logs 3.5 UEF and ranks #481 of 706.

Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), Ruud PROUH65 T2 RU350UM holds a +1.00 UEF (+40.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 900 kWh/yr for Ruud PROUH65 T2 RU350UM runs ~$163/yr vs. ~$622/yr for a 0.92 UEF electric tank.

State electric sensitivity for Ruud PROUH65 T2 RU350UM: 10-year operating spend spans $1,317 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,246 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping Ruud PROUH65 T2 RU350UM (3.5 UEF)? Check Friedrich PROH65 T2 FD310BM (3.5 UEF, at parity) and Rheem CPRO H65 T2 RH310BM (3.5 UEF, at parity).

Which Specs Set Ruud PROUH65 T2 RU350UM Apart From Cohort Averages?

Ranked #481 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, Ruud PROUH65 T2 RU350UM is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRuud95 certified listingsENERGY STAR PD 3994187
Model NumberPROUH65 T2 RU350UMDraw pattern: High-UsagePROUH65 T2 RU350UM
Uniform Energy Factor (UEF)3.5-0.20 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)75 gal+3 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use900 kWh/yr-172 kWh/yr vs. 1,072 kWh/yr medianEst. $163/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency409%-20.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)64.2" H x 24.3" DVerify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 21 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-10-15Certified 2026-10-15Markets: United States

How Do Regional kWh Prices Impact PROUH65 T2 RU350UM Over 10 Years?

Using EIA Table 5.6.A benchmarks, Ruud PROUH65 T2 RU350UM's 900 kWh/yr draw translates to roughly $163/yr on typical US residential bills.

Estimated Annual Electricity Cost by State Rate (900 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$163.00/yrHawaii$425.00/yrCalifornia$268.00/yrTexas$143.00/yrWashington$132.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $163/yr $1,634 $4,584
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $425/yr $4,246 $11,908
California 29.75 ¢/kWh ($0.2975) $268/yr $2,678 $7,509
Texas 15.91 ¢/kWh ($0.1591) $143/yr $1,432 $4,016
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $132/yr $1,317 $3,693
Estimated electricity spend (900 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should Ruud Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC SaferProducts snapshot includes 2 filings tied to Ruud; verify whether your PROUH65 T2 RU350UM production run falls inside affected ranges. See Serial Number Lookup.

2 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
  • Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)

How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH65 T2 FD310BM Hybrid/Electric Heat Pump 59 gal 75 gal 3.5 (at parity) 900
Rheem CPRO H65 T2 RH310BM Hybrid/Electric Heat Pump 59 gal 75 gal 3.5 (at parity) 900
Richmond 10CE65-HP5U15 Hybrid/Electric Heat Pump 59 gal 54 gal 3.55 (+0.05) 887
A. O. Smith HPACO-45 1**+AXST-66 1** Hybrid/Electric Heat Pump 60 gal 82 gal 3.7 (+0.20) 1,341
Friedrich PROH65 T2 FD310UM Hybrid/Electric Heat Pump 59 gal 75 gal 3.5 (at parity) 900

What Installation Caveats Apply Before Buying Ruud PROUH65 T2 RU350UM?

Even high-UEF units like Ruud PROUH65 T2 RU350UM (3.5 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • Ruud PROUH65 T2 RU350UM needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Ruud PROUH65 T2 RU350UM directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Ruud PROUH65 T2 RU350UM Strong Fit — 3.5 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH65 T2 FD310BM footprint.

Frequently Asked Technical Questions: Ruud PROUH65 T2 RU350UM

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is Ruud PROUH65 T2 RU350UM eligible for continued manufacture past May 6, 2029?

At 3.5 UEF, Ruud PROUH65 T2 RU350UM achieves Pass: +1.00 / +40.0% for the 2029 DOE standard and stands #481 of 706 against Friedrich PROH65 T2 FD310BM and Rheem CPRO H65 T2 RH310BM.

How tall and wide is Ruud PROUH65 T2 RU350UM, and what service clearance is needed?

Physical dimensions for Ruud PROUH65 T2 RU350UM are 64.2 in. height and 24.3 in. diameter (verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" d)); verify stair turns and drain pan width before delivery.

Will Ruud PROUH65 T2 RU350UM require upgrading household electrical panels or gas piping?

Ruud PROUH65 T2 RU350UM draws 240V at 21A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

Is Ruud PROUH65 T2 RU350UM economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $163/yr ($1,630 over 10 years) to power Ruud PROUH65 T2 RU350UM at 900 kWh/yr under the 18.16 cents/kWh US average (ranging from $132/yr in Washington hydro tiers up to $425/yr in Hawaii).

Which installation bottlenecks limit Ruud PROUH65 T2 RU350UM?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, Ruud PROUH65 T2 RU350UM drops into resistance mode more often.

How does Ruud PROUH65 T2 RU350UM handle simultaneous showers and laundry?

Delivering 75 gal in the first hour (+3 gal vs. 72 gal median), Ruud PROUH65 T2 RU350UM combines 59 gal tank storage with rapid burner/element recovery.

How long is the warranty on Ruud PROUH65 T2 RU350UM and how do you decode its serial?

CPSC SaferProducts records show 2 brand-level recall notices mentioning Ruud as of 2026-11-23, including #07108 (2007-02-21). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

How do 2026 post-OBBBA rebates affect buying Ruud PROUH65 T2 RU350UM?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH65 T2 FD310BM (3.5 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks