VAUGHN THERMAL MP120FHPT Water Heater Specifications (3.5 UEF)
With PD 4518063 certification, VAUGHN THERMAL MP120FHPT (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.5 UEF rating across its 119-gallon nominal tank, 115 gal First Hour Rating, standing #481 of 706 across 706 peers with Pass: +1.00 / +40.0% for May 6, 2029. Rated annual electricity draw of 1,418 kWh/yr equates to roughly $258/yr ($2,575 over 10 years) at 18.16 cents/kWh. Closest certified alternative is SANCO2 GS5-45HPC-D HP + ECO-119GLBK (3.72 UEF).
- Uniform Energy Factor
- 3.5 UEF
- Cohort UEF Rank
- #481 of 706
- First Hour Rating
- 115 gal
- Storage Volume
- 119 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.00 / +40.0%

ENERGY STAR certification places VAUGHN THERMAL MP120FHPT at 3.5 UEF (#481 of 706; -0.20 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.
May 6, 2029 readiness: VAUGHN THERMAL MP120FHPT stands +1.00 UEF (+40.0%) relative to 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,418 kWh/yr for VAUGHN THERMAL MP120FHPT runs ~$258/yr vs. ~$980/yr for a 0.92 UEF electric tank.
State electric sensitivity for VAUGHN THERMAL MP120FHPT: 10-year operating spend spans $2,075 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,690 in Hawaii (Highest EIA State) (47.18 cents/kWh).
In the Hybrid/Electric Heat Pump tier, SANCO2 GS5-45HPC-D HP + ECO-119GLBK (3.72 UEF, delta +0.22) and Reclaim Energy MP120F-RC (3.75 UEF, delta +0.25) bracket VAUGHN THERMAL MP120FHPT.
How Complete Are the Certified Metrics for VAUGHN THERMAL MP120FHPT?
Standing at #481 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, VAUGHN THERMAL MP120FHPT brings measurable deltas in recovery, footprint, and energy efficiency.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | VAUGHN THERMAL | 13 certified listings | ENERGY STAR PD 4518063 |
| Model Number | MP120FHPT | Draw pattern: High-Usage | MP120FHPT |
| Uniform Energy Factor (UEF) | 3.5 | -0.20 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 115 gal | +43 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,418 kWh/yr | +346 kWh/yr vs. 1,072 kWh/yr median | Est. $258/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 361% | -68.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 86" H x 30" D | Needs >72 in. overhead clearance; tight at 28 in. door (30" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 23 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Sound Pressure Level | 54 dBA | +5 dBA vs. 49 dBA median | Indoor placement check |
| Certification Date | 2025-12-12 | Certified 2025-12-12 | Markets: United States, Canada |
What Is the Projected Utility Bill for MP120FHPT by State?
At 1,418 kWh/yr, VAUGHN THERMAL MP120FHPT averages about $258/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $258/yr | $2,575 | $7,222 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $669/yr | $6,690 | $18,763 |
| California | 29.75 ¢/kWh ($0.2975) | $422/yr | $4,219 | $11,832 |
| Texas | 15.91 ¢/kWh ($0.1591) | $226/yr | $2,256 | $6,327 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $207/yr | $2,075 | $5,818 |
Are VAUGHN THERMAL Models Affected by Current CPSC Notices?
Zero brand-level CPSC hazard notices matched VAUGHN THERMAL in our 2026-11-23 feed; decode your water heater's serial number below to confirm warranty status. See Serial Number Lookup.
Which 5 Models Offer Similar Output to MP120FHPT?
Ordered by minimal capacity and UEF spread relative to VAUGHN THERMAL MP120FHPT, these five certified peers give direct replacement benchmarks.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| SANCO2 GS5-45HPC-D HP + ECO-119GLBK | Hybrid/Electric Heat Pump | 119 gal | 134 gal | 3.72 (+0.22) | 1,333 |
| Reclaim Energy MP120F-RC | Hybrid/Electric Heat Pump | 119 gal | 121 gal | 3.75 (+0.25) | 1,296 |
| Smart Solar SSG2-ES 120 | Hybrid/Electric Heat Pump | 120 gal | 83 gal | 2.85 (-0.65) | 1,741 |
| Hubbell ME120HPT | Hybrid/Electric Heat Pump | 109 gal | 105 gal | 3.38 (-0.12) | 1,467 |
| SANCO2 GS5-45HPC HP + ECO-119GLBK | Hybrid/Electric Heat Pump | 119 gal | 134 gal | 3.72 (+0.22) | 1,333 |
When Should Homeowners Skip VAUGHN THERMAL MP120FHPT (Hybrid/Electric Heat Pump)?
Check VAUGHN THERMAL MP120FHPT's mechanical constraints—including utility space, Electric capacity, and Pass: +1.00 / +40.0% status—against typical residential installations.
Key Limitations & Exclusions
- VAUGHN THERMAL MP120FHPT needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 54 dBA; avoid mounting VAUGHN THERMAL MP120FHPT directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Practical Specs & Code Questions for VAUGHN THERMAL MP120FHPT
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Will VAUGHN THERMAL MP120FHPT stay compliant after the May 6, 2029 DOE standard takes effect?
Tested at 3.5 UEF, VAUGHN THERMAL MP120FHPT shows Pass: +1.00 / +40.0% relative to May 6, 2029 federal DOE limits while placing #481 of 706 among 706 Hybrid/Electric Heat Pump peers like SANCO2 GS5-45HPC-D HP + ECO-119GLBK.
Will VAUGHN THERMAL MP120FHPT fit through a standard utility door and 72-inch basement ceiling?
Measuring 86 in. tall by 30 in. diameter, VAUGHN THERMAL MP120FHPT notes: needs >72 in. overhead clearance; tight at 28 in. door (30" d). Reserve space above the jacket for T&P piping and anode removal.
Do existing utility hookups support VAUGHN THERMAL MP120FHPT during replacement?
Electrical specs for VAUGHN THERMAL MP120FHPT call for 240V at 23A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.
What is the estimated 10-year operating spend for VAUGHN THERMAL MP120FHPT?
At 18.16 cents/kWh national residential pricing, VAUGHN THERMAL MP120FHPT's 1,418 kWh/yr draw equals roughly $258 annually or $2,580 across a 10-year horizon (ranging from $207/yr in Washington hydro tiers up to $669/yr in Hawaii).
When is VAUGHN THERMAL MP120FHPT a poor fit for a residential replacement?
Avoid placing VAUGHN THERMAL MP120FHPT directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 54 dBA sound and cool exhaust airflow.
What First Hour Rating or flow capacity does VAUGHN THERMAL MP120FHPT deliver?
With 115 gal FHR (+43 gal vs. 72 gal median), VAUGHN THERMAL MP120FHPT fits larger 3–5 person homes cleanly.
How do you verify manufacturing age and recall status on VAUGHN THERMAL MP120FHPT?
Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for VAUGHN THERMAL; verify exact manufacturing week for VAUGHN THERMAL MP120FHPT using the Serial Number Lookup tool.
Does VAUGHN THERMAL MP120FHPT qualify for DOE HEAR incentives after 25C expired?
After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for VAUGHN THERMAL MP120FHPT. Closest peer in Hybrid/Electric Heat Pump is SANCO2 GS5-45HPC-D HP + ECO-119GLBK (3.72 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)