Senville SENWH-HP65US Water Heater Specifications (3.9 UEF)
With PD 4518093 certification, Senville SENWH-HP65US (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.9 UEF rating across its 60-gallon nominal tank, 80 gal First Hour Rating, standing #144 of 706 across 706 peers with Pass: +1.40 / +56.0% for May 6, 2029. Rated annual electricity draw of 1,240 kWh/yr equates to roughly $225/yr ($2,252 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Bosch TR7000T-65CA (3.9 UEF).
- Uniform Energy Factor
- 3.9 UEF
- Cohort UEF Rank
- #144 of 706 (top 22.9%)
- First Hour Rating
- 80 gal
- Storage Volume
- 60 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.40 / +56.0%

ENERGY STAR certification places Senville SENWH-HP65US at 3.9 UEF (#144 of 706; +0.20 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.
May 6, 2029 readiness: Senville SENWH-HP65US stands +1.40 UEF (+56.0%) relative to 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,240 kWh/yr for Senville SENWH-HP65US runs ~$225/yr vs. ~$955/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).
State electric sensitivity for Senville SENWH-HP65US: 10-year operating spend spans $1,814 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,850 in Hawaii (Highest EIA State) (47.18 cents/kWh).
In the Hybrid/Electric Heat Pump tier, Bosch TR7000T-65CA (3.9 UEF, at parity) and Custom Comfort CCOHPWH65A (3.9 UEF, at parity) bracket Senville SENWH-HP65US.
How Do Senville SENWH-HP65US Specs Compare to Hybrid/Electric Heat Pump Medians?
Senville SENWH-HP65US places #144 of 706 (top 22.9%) across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Senville | 4 certified listings | ENERGY STAR PD 4518093 |
| Model Number | SENWH-HP65US | Draw pattern: High-Usage | SENWH-HP65US |
| Uniform Energy Factor (UEF) | 3.9 | +0.20 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 80 gal | +8 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,240 kWh/yr | +168 kWh/yr vs. 1,072 kWh/yr median | Est. $225/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 450% | +21.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 45.5" H x 21.8" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 24 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Sound Pressure Level | 49 dBA | quieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA median | Indoor placement check |
| Certification Date | 2025-12-12 | Certified 2025-12-12 | Markets: United States, Canada |
What Does SENWH-HP65US Cost to Operate Across State Electricity Rates?
At 1,240 kWh/yr, Senville SENWH-HP65US runs roughly $225/yr on the EIA national average tier under August 2026 Table 5.6.A rates.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $225/yr | $2,252 | $7,295 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $585/yr | $5,850 | $18,952 |
| California | 29.75 ¢/kWh ($0.2975) | $369/yr | $3,689 | $11,951 |
| Texas | 15.91 ¢/kWh ($0.1591) | $197/yr | $1,973 | $6,391 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $181/yr | $1,814 | $5,877 |
Are There Active CPSC Safety Recalls for Senville Water Heaters?
Zero active CPSC recalls matched Senville in our 2026-11-23 SaferProducts sweep; verify your individual tank date code via our lookup tool. See Serial Number Lookup.
Which Certified Water Heaters Match SENWH-HP65US Most Closely?
These 5 competing Hybrid/Electric Heat Pump units sit nearest to Senville SENWH-HP65US by storage capacity and 3.9 UEF rating.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Bosch TR7000T-65CA | Hybrid/Electric Heat Pump | 60 gal | 80 gal | 3.9 (at parity) | 1,240 |
| Custom Comfort CCOHPWH65A | Hybrid/Electric Heat Pump | 60 gal | 80 gal | 3.9 (at parity) | 1,240 |
| Eco-Logical ECO-65HPM1A | Hybrid/Electric Heat Pump | 60 gal | 80 gal | 3.9 (at parity) | 1,240 |
| Kepler AZMCHW-65VN3A | Hybrid/Electric Heat Pump | 60 gal | 80 gal | 3.9 (at parity) | 1,240 |
| Bosch TR7000T-65US | Hybrid/Electric Heat Pump | 60 gal | 80 gal | 3.9 (at parity) | 1,240 |
Which Home Setups Are NOT a Fit for Senville SENWH-HP65US?
Comparing Senville SENWH-HP65US against Bosch TR7000T-65CA requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.
Key Limitations & Exclusions
- Senville SENWH-HP65US needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Senville SENWH-HP65US directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
What Are the Key Questions About Senville SENWH-HP65US?
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does Senville SENWH-HP65US score under 10 CFR 430.32 May 2029 water heater minimums?
Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Senville SENWH-HP65US logs 3.9 UEF (Pass: +1.40 / +56.0%) within the 706-unit Hybrid/Electric Heat Pump group.
What physical clearance dimensions apply when installing Senville SENWH-HP65US?
With a 45.5 in. height and 21.8 in. diameter, Senville SENWH-HP65US fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d), plus 6–12 in. above for plumbing shutoffs.
What 240V circuit or IFGC fuel line capacity fits Senville SENWH-HP65US?
Powered via 240V at 24A max, Senville SENWH-HP65US requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.
How do state electricity prices change annual costs for Senville SENWH-HP65US?
Annual electric spend for Senville SENWH-HP65US (1,240 kWh/yr) averages $225/yr nationwide (ranging from $181/yr in Washington hydro tiers up to $585/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.
What homeowner setups should avoid choosing Senville SENWH-HP65US?
Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Senville SENWH-HP65US.
Is Senville SENWH-HP65US sized adequately for a 2-to-4-person household?
ENERGY STAR certifies Senville SENWH-HP65US at 80 gal First Hour Rating (+8 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.
Does Senville have active CPSC SaferProducts notices affecting SENWH-HP65US?
Zero CPSC recall alerts matched Senville (2026-11-23 check). Keep your Senville SENWH-HP65US serial code handy to track standard 6-to-12-year OEM warranty coverage.
Which competing water heater matches Senville SENWH-HP65US (3.9 UEF) most closely?
State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Senville SENWH-HP65US. Closest peer in Hybrid/Electric Heat Pump is Bosch TR7000T-65CA (3.9 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)